Technical specifications

Art. UT2010

GENERAL DATA

Type

Modular

Product height (mm)

90

Product width (mm)

100

Product depth (mm)

35

Product colour

Black RAL9005, Transparent, Aluminium

Product weight (g)

275

Coating material type

Polycarbonate, Aluminium alloy

Flush mounting

Yes, with specific accessory

Surface mounting

Yes, with specific accessory

COMPATIBLE SYSTEMS

Simplebus 2 audio/video with 

power supply unit art. 1210/1210A

Yes

Simplebus 2 audio/video kit with

power supply unit art. 1209

Yes

Simplebus 2 audio with 

power supply unit art. 1210/1210A

Yes

AUDIO SPECIFICATIONS

Microphone

MEMS digital audio sensor, omnidirectional

Loudspeaker

28 mm (Ø), 8 Ohm, 1W (2)

Technologies implemented

Full-Duplex

ELECTRICAL SPECIFICATIONS

Type of power supply

Power supply via video entry bus

Power supply voltage

33 VDC

Absorption in standby (W)

1.5

Maximum absorption (W)

3.5

HARDWARE CHARACTERISTICS

Call type

Buttons

Type of buttons

Mechanical

Number of buttons (no.)

2

Backlighting colour

White, Off

Terminals

L L V+ V- COM NC NO SE+ SE-/GND RTE TX- TX+ RX- RX+

Number of inputs (no.)

1

Number of outputs (no.)

2

Output type

Micro-USB

Communication port

Relay (C-NO-NC, 4A@12-24 VAC/VDC, inrush current 10A)

Twilight sensor

Yes

SETTINGS

Loudspeaker volume

Yes

Mic volume

Yes

Backlighting brightness

Yes

PROGRAMMING MODE

Manual (by means of Dip Switch) 

Yes

ViP Manager software

Yes

ENVIRONMENTAL AND CONFORMITY 

SPECIFICATIONS

IP protection rating (when installed)

IP65

IK anti-vandal protection rating

IK08

Operating temperature (°C)

-25 to 55

Operating humidity (max RH - %)

25 to 95

Environmental class

IV

Conformity and Certifications

RoHS II - 2011/65/EU (EN 50581:2012), EMC 2014/30/EU (EN 61000-6-

1:2007, EN 61000-6-3:2007+A1:2011)

MAIN FUNCTIONS

Lock-release

Yes

Number of auxiliary relays (no.)

1

Input for local key button

Yes

Input for door open signal

Yes

System status visual indications

Yes

System status audio indications

Yes

System status voice synthesis

Yes

Summary of Contents for Simplebus2 Ultra UT2010

Page 1: ...Passion Technology Design EN Simplebus2 Ultra audio module Art UT2010 TECHNICAL MANUAL...

Page 2: ...power cables 230V or higher Safe usage To ensure Comelit products are used safely carefully observe the indications provided in the Manuals Instruction sheets make sure the system created using Comeli...

Page 3: ...15 Connection of button modules Art UT9200 16 Connection of Touchscreen module Art UT9270 16 Connection of number keypad module Art UT9279M 16 Variant with separate power supply 16 Programming 17 Conf...

Page 4: ...dications for disabled individuals assistance request can be activated via programming Facility for 2 call buttons To be finished with cap single button or dual button made using aluminium or professi...

Page 5: ...or 9 Addressing and programming Dip Switches 10 Microphone volume control 11 Programming confirmation button 12 Digital microphone Use screwdriver supplied 13 Terminal block for connection RTE program...

Page 6: ...RDWARE CHARACTERISTICS Call type Buttons Type of buttons Mechanical Number of buttons no 2 Backlighting colour White Off Terminals L L V V COM NC NO SE SE GND RTE TX TX RX RX Number of inputs no 1 Num...

Page 7: ...1 UT9192 UT9194H UT9193 UT9196 UT9199 UT9194 UT9198 Housing frame UT9171 UT9172 UT9174H UT9173 UT9176 UT9179 UT9174 UT9178 Optional The entrance panel is available in flush mounted or surface mounted...

Page 8: ...8 2 1 2 UP 5 3 4 165 cm 130 cm 1 Flush mounted installation BLACK RED Optional Optional...

Page 9: ...s available to download free of charge from the website pro comelitgroup com The button has a nameplate which can be written on A alternatively an adhesive label can be applied B The total thickness o...

Page 10: ...10 Installation with side by side boxes Before installing the boxes in the wall fit the spacers...

Page 11: ...11 165 cm 130 cm 2 UP 5 3 4 UP 1 2 3 1 Wall mounted installation Optional BLACK RED Optional...

Page 12: ...DF to print the entrance panel name cards using the adhesive pre cut sheets C available in our catalogue Art UT9110 Custom engraved Full Metal Ultra nameplates are available on request Find out how ht...

Page 13: ...13 Installation with side by side boxes...

Page 14: ...C O M L L V V 1210A 1210 ON 1 2 3 4 6 7 5 8 UT2010 UT2010 Connections UT2010 connections UT2010 connections with separate power supply Max 20 m Local door opener button Max 20 m Local door opener butt...

Page 15: ...l module consumption table Code Consumption mA UT9200 Call button modules 12 5 UT9240 Information module 12 5 UT9240M Metal information module 12 5 UT9279M Number keypad module 40 Relays disabled and...

Page 16: ...10A 1210 UT9279M E T R GND SE SE NO NC C O M L L V V UT2010 Connection of button modules Art UT9200 Connection of Touchscreen module Art UT9270 Variant with separate power supply Connection of number...

Page 17: ...A Configuring the button type to maintain during normal operation single dual DIP 6 configuring button type Single button DIP6 ON Dual button DIP6 OFF default I Address button modules DIP 1 5 addressi...

Page 18: ...6 7 5 8 5 example code 1 Set the address of the apartment you wish to call for example 1 using the DIP switches see Addressing table 8 7 6 5 default OFF 8 7 6 5 ON 2 DIP 6 configuring button type Sing...

Page 19: ...e DIP switches see Addressing table S1 S2 8 8 7 6 5 default OFF 8 7 6 5 ON 9 DIP 6 configuring button type Single button DIP6 ON Dual button DIP6 OFF default 25 6 ON 1 2 3 4 6 7 5 8 ON 1 2 3 4 6 7 5 8...

Page 20: ...hes in accordance with the function you wish to program see Special programming table 2 Press the confirm button 7 Reset the configuration of the DIP switches S1 S2 6 LL 1 2 Take note of the DIP switc...

Page 21: ...on actuator command 4 sec 231 1 2 3 6 7 8 C NC NO relay activation on actuator command 8 sec Door lock 184 4 5 6 8 Door lock time 100 msec 185 1 4 5 6 8 Door lock time 200 msec 186 2 4 5 6 8 Door lock...

Page 22: ...tton repeatedly for each module to change the individual brightness of the buttons see Adjusting the brightness of the button LEDs 162 2 6 8 Light me OFF default 163 1 2 6 8 Light me ON the button LED...

Page 23: ...he day To change the setting to ON LEDs always on or OFF LEDs always off proceed as follows NOTE when the OFF and AUTO lighting modes are active every time the entrance panel is powered the buttons li...

Page 24: ...nt to check AUTO mode operation for the twilight sensor you can proceed as follows 1 Enter programming mode 2 Block the twilight sensor for 5 seconds If AUTO mode has been set the camera and button LE...

Page 25: ...ting the button brightness Press a button repeatedly for each module to change the individual brightness of the buttons 2 Take note of the DIP switch settings OFF ON 1 2 3 4 6 7 5 8 2 ON 1 2 3 4 6 7 5...

Page 26: ...ion button backlighting is only enabled on the user s request by pressing the LIGHT ME button on the audio video module this saves energy and reduces light pollution Backlighting management for this b...

Page 27: ...ing settings 3 Press the confirm programming button the green lock release LED will start flashing at the end of the backup approx 30 sec the green lock release LED switches off the green audio enable...

Page 28: ...ing activations that can be assigned to the module SE outputs and relay You will need a USB micro USB cable System performance and layouts For further information regarding system performance and to v...

Page 29: ...2 7 8 224 6 7 8 15 1 2 3 4 45 1 3 4 6 75 1 2 4 7 105 1 4 6 7 135 1 2 3 8 165 1 3 6 8 195 1 2 7 8 225 1 6 7 8 16 5 46 2 3 4 6 76 3 4 7 106 2 4 6 7 136 4 8 166 2 3 6 8 196 3 7 8 226 2 6 7 8 17 1 5 47 1...

Page 30: ...2st edition 06 2021 code 2G40002703 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...