respiratory tract and can cause effects on the central nervous system, eyes and lungs that can be damaged by the 
inhalation of high concentrations. 

OPERATIONAL DESCRIPTION 

The electrochemical sensor is temperature compensated, but is sensitive to extreme humidity variations. 

Preheating

: when powered, the sensor needs a time of preliminary heating of about 60 seconds. During this peri-

od the yellow LED “

FAULT

” flashes. After this period, the yellow LED light off, the green LED “

ON

” illuminates to in-

dicate normal functioning. After this period the unit is able to detect gas even if it attains the optimum stability con-
ditions after about 15 minutes continual functioning.  

Normal operation

: the green LED “

ON

” should be light on. 

ALARMS:

 different alarms levels can be set by Dip-Switch (

see table 2

). 

The 1st° Red LED

 (

ALARM 1

) illuminates when  the Gas concentration  attains 1st alarm level.  And  after about 3 

seconds the “ALARM 1" relay will activate. 

The  2nd  Red  LED

  (

ALARM 2

)  illuminates  when  the  Gas  concentration  attains  2nd  alarm  level  and  after  about  3 

seconds, the “ALARM 2" relay will activate. 

The  3rd  Red  LED

  (

ALARM  3

)  illuminates  when  the  Gas  concentration  attains  3rd  alarm  level  and  after  about  3 

seconds, the “ALARM 3" relay will activate. 

Faults

the instrument signal different kind of failures, as listed below. The Yellow LED illuminates, the "

S

" output 

falls down to 0mA and the “

FAULT

 normally activated relay deactivate. The "

FAULT

" relay, if necessary, can be used 

both to signal remotely an occurred damage and to signal the absence of power to the instrument. 

Yellow LED illuminates each 4 seconds (

with Green LED activate

):

 

this happens when the “

Cartridge Sensor

” has 

overcome  its  theoretical  period  of  life  (2  years  approximately)  and  its  correct  operation  is  no  longer  guaranteed. 
The detector keeps on operating normally but it is necessary to replace, as soon as possible, the “

Cartridge Sen-

sor

” with a new one. The type to be required is described at 

Page1

. The replacement procedure is described in the 

attached manual. 

Yellow  LED  activates,  Green  LED  off  (

FAULT  relays  activate  and  0mA  output  signal

):

 

this  signal  different  kind  of 

faults. 

1)

  The  Dip  Switch  set  up  is  wrong,  please  verify  (

see  Table  2

). 

2)

  The  “

Cartridge  Sensor

”  is  not  working, 

please  replace  with  new  one. 

3)

 

If  a  new

 

Cartridge  Sensor

”  is  installed  or  it  is  not  correctly  connected  or  a  not 

compatible one is mounted. Please check the cartridge connections and compatibility (

see Table 3

) these checks are 

made connecting and disconnecting the device.

 

If the condition does not change, it will be necessary to replace the 

unit and/or send it back to the supplier to repair. 

Yellow and Green LED activates (

FAULT relays activate and 0mA output signal

):

 

this happens when the “

Cartridge 

Sensor

” is not working. First try to perform the procedure of “

Calibration in Air

” as described in the section

 “Test 

and  Calibration  >  Calibration  in  Air”

,  finally  try  to  replace  a  new 

“Cartridge  Sensor

”.  If  the  condition  is  not 

change, it will be necessary to replace the unit and/or send it back to the supplier to repair. 

All LED activate (

FAULT relays activate and >24mA output signal

):

 

this happens  when the “

Cartridge Sensor

”  is not 

working or gas concentration is out of scale (higher than 30%v/v O

2

). If there are not any gas leaks and the condi-

tion is not change, it will be necessary to replace the unit and/or send it back to the supplier to repair. 

INSTALLATION 

The detector must be accurately installed according to the national dispositions in force on the safety of the plants 
and installation of electric devices. 

Detector positioning

:

 The 

Fig. 2

 shows the instrument size. The unit must be positioned vertically with the sensor 

downwards. 

It should be fixed at 1.60 m from the floor (the O

2

 gas is lighter as air). 

Electrical Connection (

see Fig.2

)

: the maximum distance to install each detector from the power supply show in the 

Table 1

.

 If more than one detector is to be powered in parallel, it is necessary to consider the voltage drop across 

the supply cable. Normally use a two wire cable (

not shielded

) for power  the conductors for output relay. 

If 

the output signal is used in mA, please use 3 conductors screened  conductors for relay output. The max 
load resistor is 50 ohm with 12Vdc power supply, while is 400 ohm with 24Vdc power supply (

see Fig.4

). 

Power Supply terminals, on the main board, are plug-in type, it is necessary to extract them to make the connec-
tion. Pay attention when you insert them again, being polarized. The relays terminals, on outputs board, are fixed.

 

The sealed relays are

 

tension free 

SPST (

S

ingle 

P

ole 

S

ingle 

T

hrow)

 

contacts and should be set NO (Normally Open) or 

NC (Normally Closed) by positioning the 4th Dip-Switch (

see Table 3

). With the

 

Dip-Switches from 1 to 3 the concen-

tration for alarm activations is determined. 

Note: Dip-Switch should be set with instrument powered off. Dip-Switch settled in reserved position acti-

vate Fault indications (

see Operational Description > Faults

). 

Important:

 

Once  installation  is  completed,

 

power  up  the  unit,  wait  about 

20÷30  minutes

  and  then  to  adjust  the 

sensor to the environment, 

only if it is necessary

,

 

carry out the 

Calibration in Air 

(

see

 Test and Calibration

).

 

WARNING 

Average life

: The sensitive element used in this detector has an excellent stability in time. In fresh air and in nor-

mal working condition the 

sensor's life is

 

about 2 years

. After this period the yellow LED “

FAULT

” flashes every 4 

seconds, is necessary replacing the “

Cartridge Sensor

”. 

Periodical testing

: we advise to carry out working tests every 6 or 12 months as explained in the chapter “

Tests 

and Calibration

”. 

Summary of Contents for SE237EO

Page 1: ... Temps de réponse T90 20 secondi seconds secondes Ripetibilità Repeatability Répétitivité 1 del segnale signal Precisione Accuracy Precision 2 del segnale in aria signal in air du signal en air Deriva a lungo termine Long time drift Dérive à long terme 2 segnale mese signal per month du signal chaque mois 5 sulla vita operativa over Operating Life sur sa vie Temp umidità di funzionamento Operation...

Page 2: ...secondi il Led giallo si spegne e si accende il Led verde ON che indica il normale funzionamento Dopo questo tempo il sensore è in grado di rilevare il gas ma raggiunge le condizioni di stabilità ottimali dopo circa 15 minuti di funzionamento continuo Funzionamento Normale deve essere acceso il solo Led Verde ON ALLARMI i 3 livelli d allarme possono essere impostati con diverse soglie utilizzando ...

Page 3: ...e oltre il 30 In questi casi il sensore deve essere sostituito Attenzione i sensori elettrochimici per Ossigeno contengono una piccola quantità di acetato di potassio che è corrosivo Normalmente non avvengono perdite dal sensore questo può essere causato solo da un azione mecca nica violenta o un uso oltre i limiti di funzionamento Il sensore contiene anche piccole quantità di piombo ossido di pio...

Page 4: ... i puntali del milliamperometro direttamente sui morsetti S e verificare che ci sia 17 4mA circa Applicando il gas al 15 O2 controllare che si raggiunga un valore di circa 136mV ovvero che l uscita in mA diminuisca fino a circa 13 6 mA Poi i valori dopo aver tolto il gas torneranno progressivamente al valore normale in aria Regolazione Fine Uscita in mA Codice Reg Fine F2 F1 F1 F2 questa funzione ...

Page 5: ...to repair Yellow and Green LED activates FAULT relays activate and 0mA output signal this happens when the Cartridge Sensor is not working First try to perform the procedure of Calibration in Air as described in the section Test and Calibration Calibration in Air finally try to replace a new Cartridge Sensor If the condition is not change it will be necessary to replace the unit and or send it bac...

Page 6: ... Led relay ALARM1 with the 1 red Led relay ALARM2 with the 2 red Led relay ALARM3 with the 3 red Led At the end all the Led will remain lighted for around 5 seconds then the central returns at the conditions of normal operation It is advisable to perform this operation every 6 12 months according to the use Note this function is not working if the 1 and or the 2 and or the 3 red Led have already t...

Page 7: ... fication et calibrage en utilisant par codes les touches F1 et F2 CARACTÉRISTIQUES DU GAZ L Oxygène O2 est un gaz incolore inodore légèrement plus lourd que l air sa densité relative à l air est de 1 1 Ce n est pas un gaz inflammable mais étant fortement oxydant il réagit avec les matériaux combustibles et réduc teurs en facilitant leur combustion déterminant ainsi des risques d incendie et d exp...

Page 8: ...e Tableau 1 en fonction de la section du câble utilisé Dans le cas d alimentation de plusieurs détecteurs en parallèle il est nécessaire de calculer la chute de tension sur les portions communes des câbles Un câble sans écran est normalement utilisé avec 2 conducteurs pour l alimentation les conducteurs pour les sorties relais Dans le cas où l on utilise également le signal de sortie en 4 20 mA il...

Page 9: ...gnote chaque 8 secondes dans ce cas inter rompre la procédure puis exécutez le contrôle en coupant et en rétablissant l alimentation du détecteur En cas de persistance il sera nécessaire de remplacer et ou renvoyer le détecteur au fournisseur pour réparation Important Durant l opération de étalonnage l appareil portant la sortie S au 0mA L étalonnage doit être exécuté en air propre exclusivement m...

Page 10: ...rom the 12Vdc power Supply Distance max d installation d un détecteur sous 12Vcc Massima distanza cui può essere installato ogni rivelatore se è alimentato a 24Vcc The maximum distance to install each detector from the 24Vdc power Supply Distance max d installation d un détecteur sous 24Vcc 0 75 mm2 26 Ω km 100 m 300 m 1 mm2 20 Ω km 150 m 400 m 1 5 mm2 14 Ω km 200 m 500 m 2 5 mm2 8 Ω km 400 m 800 ...

Page 11: ...mento Wiring diagram Schéma TESTmV TP2 TP1 Scheda Uscite Relé Relays Output Board Sortie sur Realis S 12 24V mA 12 24Vdc Alimentazione Power Supply Alimentation Fig 3 Tester di calibrazione Calibration Tester Kit de Calibration F1 F2 Tasti Key Touches TC014 0 3 L min 1 L min Alimentazione Power Supply Alimentation 100 300 400 500 50 0 5 200 Vdc RL Resistenza di carico Load resistor Resistance de c...

Reviews: