10
Button configuration
By default the buttons control the functions in row
A
(“Standard configuration” table).
It is possible to change the default configuration of the buttons by changing the positions of S2 DIP-switches 1-2-3-4 on the rear
of the door-entry phone to one of the combinations (B-P) suggested in the table. All the buttons will change function.
Basic configuration
DIP-switch
S2
BUTTON PROGRAMMING
DIP 1
DIP 2
DIP 3
DIP 4
A
OFF
OFF
OFF
OFF
AP
ACT
CCS
B
ON
OFF
OFF
OFF
AP
ACT
INT
C
OFF
ON
OFF
OFF
AP
INT
D
D
ON
ON
OFF
OFF
AP
ACT
CCP
E
OFF
OFF
ON
OFF
ACT
ACT
ACT
F
ON
OFF
ON
OFF
AP
ACT
K
G
OFF
ON
ON
OFF
AP
ACT
D
H
ON
ON
ON
OFF
AP
INTb
INT
I
OFF
OFF
OFF
ON
AP
CCS
PAN
J
ON
OFF
OFF
ON
AP
K
CCS
K
OFF
ON
OFF
ON
AP
CCP
K
L
ON
ON
OFF
ON
AP
PAN
CCP
M
OFF
OFF
ON
ON
AP
INTb
PAN
N
ON
OFF
ON
ON
AP
INT
INT
P
OFF
ON
ON
ON
NULL
NULL
NULL
ON
ON
ON
ON
PROG
Legend
AP
Lock-release
ACT
Actuator
CCP
*
Call to main switchboard
CCS
*
Call to secondary switchboard
K
Caretaker door-entry phone call
D
**
Automatic door opening on receipt of call [Doctor mode]
PAN
*
Priority call to switchboard
INT
Intercom call (general programmable or to selective address).
Single-family call by default
INTb
Two-family intercom [KIT only]
NULL
No function
PROG
With these S2 DIP-switch settings, the buttons control the programmed functions as in
.
*
Cannot be used in Kit systems
**
Pressing and holding enables / disables the function
, see
“Pressing and holding keys (Disabled by default from
default