background image

5

Legend: buttons and indicator LEDs

 

f

Press the desired button once to activate the associated function

Wait for approximately 1 sec. before pressing the same button again. Pressing the same button several times in 

quick succession will cancel the command.

Description of buttons

Audio activation

 

f

Press the button to answer an incoming call.

Lock-release command 

(default)

*

 [programmable]

 

f

Press the key to activate the corresponding door 

lock.

Actuator control 

(default)

[programmable]

 

f

Press the key to activate the corresponding 

relay.

Secondary switchboard 

(default)

[programmable]

 

f

Press the key to call the secondary switchboard.

Silent mode (Privacy) 

 

f

Press the key to enable silencing of the ringtone 

on receipt of a call from the external unit and 

from the switchboard.

* To change the default settings and to program other 

functions, please refer to paragraphs  

“Basic configuration"

“Advanced configuration"

Indicator LED description

steady on (in call): communication in progress 

steady on (in standby): 

Automatic answer (hands-

free)

 mode enabled 

continuous flashing: incoming call

slow flashing: door open 

1 flash after pressing button: door open confirmed 

continuous flashing: incoming call

steady on: silent (Privacy) mode enabled 

3 flashes (every 5 sec.): door opening upon call 

function (Doctor) enabled 

continuous flashing: device in programming mode 

4 flashes: system busy

Pressing and holding keys 

(Disabled by default from firmware version 1.2.0)

Pressing and holding keys adds further functions to the door-entry phone.

Carry out the procedure described below to enable - or disable, depending on the factory setting - the press and 

hold feature:

 

Door-entry phone in standby.

1. 

Take note of the S2 DIP-switch settings.

2. 

Enter programming mode by setting S2 DIP-switches 1, 3, 5 to ON.

 

» the LED   flashes

3. 

Press   to enable (or press   to disable).

4. 

Make sure the 

 key flashes 4 times and the confirmation tone is emitted.

5. 

Restore the initial configuration of the S2 DIP-switches.

 

» LED   switches off

Once the procedure is complete, you will be able to enable the following functions:

Automatic lock-release on receipt of call (Doctor mode)

Automatic activation of the Lock-release relay on receipt of a call originating from the external unit.

 

f

Press and hold (4 sec.) the programmed button to enable/disable the function.

Automatic Answer (Hands-Free mode)

Automatic audio opening on receipt of a call.

 

f

Press and hold (5 sec.) the audio activation button   to enable/disable the function.

 

»

ENABLING:    +    LED STEADY ON

 

»

DISABLING:  

 +    LED OFF

Summary of Contents for Mini 6750W

Page 1: ...EN TECHNICAL MANUAL Handsfree entry phone Mini Art 6750W 6751W Passion Technology Design...

Page 2: ...in residential commercial industrial and public buildings Installation All activities connected to the installation of Comelit products must be carried out by qualified technical personnel with caref...

Page 3: ...ire audio video systems with mixer art 4888C Simplebus2 with power supply unit art 1210 1210A or kits which use power supply unit art 1209 Complete with distribution terminal art 1214 2C Dimensions 10...

Page 4: ...phone can be used in Simplebus2 audio systems with power supply unit art 1210 1210A Dimensions 105x105x20 mm Art 6751W 1 Loudspeaker volume control f f turn clockwise to increase the value 2 Speaker...

Page 5: ...irmed continuous flashing incoming call steady on silent Privacy mode enabled 3 flashes every 5 sec door opening upon call function Doctor enabled continuous flashing device in programming mode 4 flas...

Page 6: ...ol function Yes Yes Switchboard call function Yes Yes Priority calls Yes Yes Intercom function Yes Yes Selective intercom call Yes Yes Multiple address call Yes Yes Privacy function Yes Yes Doctor Yes...

Page 7: ...7 Surface mounting optional 4 1C 1B 1A 1D 2 3 1 2 3 CLACK 4 REMOVAL...

Page 8: ...8 Terminal removal Terminal installation 2 3 1 2 L L C F P 1 C F P 2 3 1...

Page 9: ...here multiple door entry phones or door entry monitors have the same user code connect the CFP button on one only all the devices will ring simultaneously Branched connection to the video entry system...

Page 10: ...OFF OFF OFF ON AP CCS PAN J ON OFF OFF ON AP K CCS K OFF ON OFF ON AP CCP K L ON ON OFF ON AP PAN CCP M OFF OFF ON ON AP INTb PAN N ON OFF ON ON AP INT INT P OFF ON ON ON NULL NULL NULL ON ON ON ON PR...

Page 11: ...le 5 Press and release the button to be associated with the function Correct procedure indication the LED flashes for a few seconds and a confirmation tone sounds Procedure error indication the LED fl...

Page 12: ...S1 DIP switch ON Code S1 DIP switch ON Code S1 DIP switch ON 1 1 4 4 7 7 2 2 5 5 8 8 3 3 6 6 Generic actuator coded actuator Generic actuator button programming 1 Take note of the S1 DIP switch settin...

Page 13: ...6 to OFF LED switches off S2 7 Set S2 DIP switches 1 2 3 4 to ON 8 Return S1 DIP switches to the original combination Other functions button programming 1 To enter programming mode set S2 DIP switch 6...

Page 14: ...e minimum address S1 set code Addressing table S2 S2 Range maximum address Enable range Disable range Deleting the range S1 S2 2 sec Take note of the S2 S1 settings and restore on completion of progra...

Page 15: ...tor door entry phone 4 times 4 confirmation tones sound to change the floor door call ringtone Any further pressing of the button repeats the sequence described above 3 Press and release to scroll thr...

Page 16: ...137 1 4 8 167 1 2 3 6 8 197 1 3 7 8 227 1 2 6 7 8 18 2 5 48 5 6 78 2 3 4 7 108 3 4 6 7 138 2 4 8 168 4 6 8 198 2 3 7 8 228 3 6 7 8 19 1 2 5 49 1 5 6 79 1 2 3 4 7 109 1 3 4 6 7 139 1 2 4 8 169 1 4 6 8...

Page 17: ...2nd edition 03 2021 code 2G40002497 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Reviews: