GENERAL DATA

Height (mm)

160

160

160

Width (mm)

175

175

175

Depth (mm)

22

22

22

Weight: (g)

600

600

600

Material

ABS

ABS

ABS

Colour

White RAL9003

White RAL9003

White RAL9003

Surface mounting

Yes

Yes

Yes

Desk base mounting

Yes

Yes

Yes

LCD SPECIFICATIONS

Size (inches)

4.3”

4.3”

4.3”

Aspect ratio

16:9

16:9

16:9

Resolution (H x V)

480x272 pixel

480x272 pixel

480x272 pixel

AUDIO SPECIFICATIONS

Microphone

6 mm (Ø), 

Omnidirectional

6 mm (Ø), 

Omnidirectional

6 mm (Ø), 

Omnidirectional

Loudspeaker

40 (ø) x 5.1 (H) mm, 

100 Ohm, 0.25W

40 (ø) x 5.1 (H) mm, 

100 Ohm, 0.25W

40 (ø) x 5.1 (H) mm, 

100 Ohm, 0.25W

Magnetic induction function

No

Yes

No

HARDWARE CHARACTERISTICS

Type of buttons

Capacitive

Capacitive

Capacitive

Service buttons

Lock-release, Silent 

(Privacy) mode, Door 

open

Lock-release, Silent 

(Privacy) mode, Door 

open

Lock-release, Silent 

(Privacy) mode, Door 

open

No. of programmable buttons for additional

functions

2

2

6

Removable terminals

Yes

Yes

Yes

SETTINGS

Ringtone volume

Yes

Yes

Yes

Screen brightness

Yes

Yes

Yes

Screen colour

Yes

Yes

Yes

MAIN FUNCTIONS

Lock-release

Yes

Yes

Yes

Actuator control

Yes 

(Default key 1)

Yes 

(Default key 1)

Yes  

(Default key 1)

Self Activation control

Yes 

(Default key 2)

Yes 

(Default key 2)

Yes  

(Default key 2)

Switchboard call

Yes

Yes

Yes  

(Default key 3)

Alarm call transmission

Yes

Yes

Yes  

(Default key 5)

Intercom call

Yes

Yes

Yes

Multiple address call

Yes

Yes

Yes

Silent mode (Privacy)

Yes

Yes

Yes

 Door opening upon call (Doctor)

Yes

Yes

Yes

  (Default key 4)

Door open indication 

Yes

Yes

Yes

Floor door call

Yes

Yes

Yes

Customisable ringtone

Yes

Yes

Yes

ELECTRICAL SPECIFICATIONS

Type of power supply

Power supply via door entry monitor BUS

Power supply voltage

22-34 VDC (BUS)

22-34 VDC (BUS)

22-34 VDC (BUS)

Maximum absorption (W)

5.40

5.40

5.40

ENVIRONMENTAL AND CONFORMITY 

SPECIFICATIONS

IP rating

30

30

30

Operating temperature (°C)

5 to 40

5 to 40

5 to 40

Operating relative humidity (%)

25-75%

25-75%

25-75%

Environmental class

 I

 I

 I

Conformity and Certifications

RoHS II - 2011/65/EU (EN 50581:2012), EMC 2014/30/EU (EN

61000-6-1:2007, EN 61000-6-3:2007+A1:2011)

Technical specifications

Summary of Contents for Mini 6701W

Page 1: ...EN TECHNICAL MANUAL Passion Technology Design Mini door entry monitor with handset Art 6701W 6701W BM 6701W 8...

Page 2: ...ings Installation All activities connected to the installation of Comelit products must be carried out by qualified technical personnel with careful observation of the indications provided in the Manu...

Page 3: ...closure In systems with more than one door entry monitor connected in cascade only the door entry monitor furthest away must have CV5 closed 11 Pin for securing terminal block Terminal block for syste...

Page 4: ...sing and holding keys disabled by default from firmware version 3 0 1 3 2 0 for 6701W 8 INTERCOM Allows a call from one internal unit to one or more internal units CALL TO A MAIN OR SECONDARY SWITCHBO...

Page 5: ...Ringtone volume Yes Yes Yes Screen brightness Yes Yes Yes Screen colour Yes Yes Yes MAIN FUNCTIONS Lock release Yes Yes Yes Actuator control Yes Default key 1 Yes Default key 1 Yes Default key 1 Self...

Page 6: ...6 Installation optional fixing 16 0 cm 17 5 cm 1C 1B 1A 4 3 2 2 1 6 7 1 3 2 CLACK CLACK CLACK 5...

Page 7: ...C L L P F C FLOOR DOOR CALL LM LM OUT L IN L IN L OUT L 20 m MAX Use shielded cable for the connection and do not route the cables in the vicinity of heavy inductive loads or power supply cables 230V...

Page 8: ...209 1210 or 1210A you can configure a maximum of 1 main door entry monitor while in systems with power supply unit 4888C you can configure up to 2 main door entry monitors To configure the door entry...

Page 9: ...Actuator AI Self Activation CCP Call to main switchboard CCS Call to secondary switchboard K Caretaker door entry phone call PAN Priority call to switchboard INT Intercom call general programmable or...

Page 10: ...DIP switches according to the call address of the desired apartment See Addressing table 5 Press and release the button to be associated with the function Correct procedure indication the LED flashes...

Page 11: ...note of the S1 S2 settings and restore them when programming is complete Set the DIP switches as shown in the figure S1 S2 x4 x10 OK prog KO prog x4 x10 OK prog KO prog Generic actuator coded actuato...

Page 12: ...ction Correct procedure indication the LED flashes for a few seconds and a confirmation tone sounds 6 Exit programming mode by setting S2 DIP switch 6 to OFF LED switches off S2 7 Set S2 DIP switches...

Page 13: ...confirmation tones sound to change the floor door call ringtone Any further pressing of the button repeats the sequence described above 3 Press and release to scroll through the available ringtones in...

Page 14: ...46 2 3 4 6 76 3 4 7 106 2 4 6 7 136 4 8 166 2 3 6 8 196 3 7 8 226 2 6 7 8 17 1 5 47 1 2 3 4 6 77 1 3 4 7 107 1 2 4 6 7 137 1 4 8 167 1 2 3 6 8 197 1 3 7 8 227 1 2 6 7 8 18 2 5 48 5 6 78 2 3 4 7 108 3...

Page 15: ...2nd edition 03 2021 code 2G40002676 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Reviews: