Comelit Mini 6701W Technical Manual Download Page 3

3

Door entry monitor description

1.
2.

3.

5.

4.

6.

7.

8.

10.

11.

9.

L

L

CFP1

CFP2

 1.

 Brightness control

 

f

To increase the value, turn clockwise

 2.

 Colour intensity adjustment

 

f

To increase the value, turn clockwise

 3.

 4.3" colour LCD screen

 4.

 Call volume adjustment (High / Medium / Low)

 5.

 Buttons

 6.

 Handset

 

f

Lift the handset to start communication

 

Do not press and hold the audio hook while the handset is lifted

 7.

 

S1

 microswitches for programming the user code (see paragraph 

“Addressing table”

)

 8.

 

S2

 microswitches for button and function programming (marked with a red corner)

DIP 1-2-3-4

 for button function programming

DIP 5-6

 access to programming

DIP 7

 for power supply voltage management (default ON) 

 

S2 DIP 7 must always be set to ON, even in systems with 4888C and 4888CU (as in the factory settings)

DIP 8

 for setting main and secondary door entry monitor (see paragraph 

“Main and secondary door entry monitors”

)

 9.

 Loudspeaker volume adjustment (for setting intercom audio only)

10.

 

CV5

 jumper for video closure 

In systems with more than one door entry monitor connected in cascade, only the door entry monitor furthest away must 

have CV5 closed

11.

 Pin for securing terminal block

Terminal block for system connection:

LL

 Bus line connection terminals

CFP1 CFP2

 Floor door call input

Wall-mounted door entry monitor with 4.3” / 16:9 colour screen and handset. Allows brightness and colour control, plus 

adjustment of the ringtone volume, which can be customised by choosing one of several different melodies. Equipped as 

standard with 4 soft touch buttons (8 with 6701W/8) for controlling lock-release, self activation, switchboard call and Privacy 

function, as well as door status indicator LEDs. Manages floor door calls as standard. Complete with 2 x 8-position dip-

switches for programming the user code and button programming. The backplate for wall installation or domestic series box 

installation and the distribution terminal from riser art. 1214/2C are included. The door entry monitor can only be used in 

2-wire 

Simplebus2 systems

. Dimensions (L x H x D): 175x160x22 mm.

Option of adding 4 additional buttons to Art. 6701W-6701W/BM with accessory Art. 6733W.
Item 6701W/BM is not supplied with backplate 6710.

Summary of Contents for Mini 6701W

Page 1: ...EN TECHNICAL MANUAL Passion Technology Design Mini door entry monitor with handset Art 6701W 6701W BM 6701W 8...

Page 2: ...ings Installation All activities connected to the installation of Comelit products must be carried out by qualified technical personnel with careful observation of the indications provided in the Manu...

Page 3: ...closure In systems with more than one door entry monitor connected in cascade only the door entry monitor furthest away must have CV5 closed 11 Pin for securing terminal block Terminal block for syste...

Page 4: ...sing and holding keys disabled by default from firmware version 3 0 1 3 2 0 for 6701W 8 INTERCOM Allows a call from one internal unit to one or more internal units CALL TO A MAIN OR SECONDARY SWITCHBO...

Page 5: ...Ringtone volume Yes Yes Yes Screen brightness Yes Yes Yes Screen colour Yes Yes Yes MAIN FUNCTIONS Lock release Yes Yes Yes Actuator control Yes Default key 1 Yes Default key 1 Yes Default key 1 Self...

Page 6: ...6 Installation optional fixing 16 0 cm 17 5 cm 1C 1B 1A 4 3 2 2 1 6 7 1 3 2 CLACK CLACK CLACK 5...

Page 7: ...C L L P F C FLOOR DOOR CALL LM LM OUT L IN L IN L OUT L 20 m MAX Use shielded cable for the connection and do not route the cables in the vicinity of heavy inductive loads or power supply cables 230V...

Page 8: ...209 1210 or 1210A you can configure a maximum of 1 main door entry monitor while in systems with power supply unit 4888C you can configure up to 2 main door entry monitors To configure the door entry...

Page 9: ...Actuator AI Self Activation CCP Call to main switchboard CCS Call to secondary switchboard K Caretaker door entry phone call PAN Priority call to switchboard INT Intercom call general programmable or...

Page 10: ...DIP switches according to the call address of the desired apartment See Addressing table 5 Press and release the button to be associated with the function Correct procedure indication the LED flashes...

Page 11: ...note of the S1 S2 settings and restore them when programming is complete Set the DIP switches as shown in the figure S1 S2 x4 x10 OK prog KO prog x4 x10 OK prog KO prog Generic actuator coded actuato...

Page 12: ...ction Correct procedure indication the LED flashes for a few seconds and a confirmation tone sounds 6 Exit programming mode by setting S2 DIP switch 6 to OFF LED switches off S2 7 Set S2 DIP switches...

Page 13: ...confirmation tones sound to change the floor door call ringtone Any further pressing of the button repeats the sequence described above 3 Press and release to scroll through the available ringtones in...

Page 14: ...46 2 3 4 6 76 3 4 7 106 2 4 6 7 136 4 8 166 2 3 6 8 196 3 7 8 226 2 6 7 8 17 1 5 47 1 2 3 4 6 77 1 3 4 7 107 1 2 4 6 7 137 1 4 8 167 1 2 3 6 8 197 1 3 7 8 227 1 2 6 7 8 18 2 5 48 5 6 78 2 3 4 7 108 3...

Page 15: ...2nd edition 03 2021 code 2G40002676 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Reviews: