separation blade

curtain lens

support of the lens

The sensor is equipped with external and internal LED. 

In case of alarm from one technology will only turn on the LED internal (short flash for the microwave, turning on for 2 seconds to PIR). 
When PIR and MW go in alarm (AND alarm) the external led turn ON for 4 seconds.

Other reports:

- Slow flashing alternating internal and external LED: the initialization phase 
- Short flash external LED: inhibition time, result of PERMITTED passage with DIRECTION function ON (DIP 4 ON). 
- Rapid blinking of ext.LED: the last 10 seconds of the inhibition time (DIP4 ON).

1. INTRODUCTION

Art. DT01CW - Art. DT01CB

 is a dual technology curtain sensor, PIR and MW. It used for doors and windows protection. It has an 

adjustable range from 2mt to 3.5mt. And is equipped with a system for the recognition the direction of alarm. The lens used in the 
infrared has the ability to be rotated horizontally so you can install the sensor in 2 diffrenti guidelines (vertical and horizontal)

2. DESCRIPTION OF THE FUNCTION: DIRECTION ALARM

The sensor is able to detect the direction of movement so as to trig in alarm only when the passage is made in a given sense.

Activation is done by DIP4 ON. (with DIP4 OFF, the sensor triggers an alarm in both directions) The selection of the sense of alarm is 

handled through the DIP5. This function is intended for applications where the sensor is installed on the windows and / or doors often 
open, and there is continuous passage on the inner side.

The passage in NOT PERMITTED direction, generates immediate alarm signaling with LED lights outside. 
The passage in PERMITTED direction generates the activation of the inhibition time of 2 minutes, with the relative signal by short flash 

of the LED every 2 seconds. During this time period (2 minutes) there any violation of the sensor will not generate alarm. 
During the last 10 seconds of the period of inhibition, the LED will begin to flash rapidly to indicate that the sensor will return in the 
operating status and will be able to generate alarm.

Example: If the sensor is installed on access to a terrace, it is possible come and go for 2 minutes without generating an alarm. 

After this time, the sensor will be operative, giving alarm in the programmed direction.

The sensor is designed to be installed to protect the openings, for example between the window and the shutter, or to doors and gates. 

Due to the high angle of coverage and the ability to rotate the lens on the support of the pyroelectric, you can install it in different ways, 
from top to bottom or on one side.

3. LENS AND DIP-SWITCH SETUP - LED INDICATION 

Summary of Contents for DT01CW

Page 1: ...eriodo di inibizione il led esterno comincer a lampeggiare velocemente per indicare che a breve il sensore ritorner operativo e sar in grado di generare allarme Esempio se il sensore posto su l access...

Page 2: ...ONE E COLLEGAMENTO Scegliere la posizione adatta alle proprie esigenze fissare il sensore utilizzando le torrette a strappo per ottenere la protezione Tamper Il cavo pu passare dal forellino vicino ai...

Page 3: ...segni sono puramente indicativi pertanto si consiglia di testare sempre la copertura del sensore Durante la prima accensione il sensore necessita di un warm up un tempo di attivazione per andare a reg...

Page 4: ...th DIP4 OFF the sensor triggers an alarm in both directions The selection of the sense of alarm is handled through the DIP5 This function is intended for applications where the sensor is installed on...

Page 5: ...separator see figure and install it paying attention to the direction selection dip swtch5 4 INSTALLATION AND CONNECTION Choose a suitable location mount the sensor using the turrets tear to get the...

Page 6: ...de The drawings are for guidance only so you should always test the sensor At start up the sensor needs a warm up time this time is about 40 There will be fewer violations during this time is the fast...

Page 7: ...90 120cm 20cm FRONT VIEW SIDE VIEW 90 120cm 20cm FRONT VIEW SIDE VIEW...

Page 8: ...s any responsibility when changes or unauthorized repairs are made to the product system It is recommended to test the operation of the alarm product system at least once a month Despite frequent test...

Reviews: