Addition of actuator Art. 1256
Diagram BK/AC
Page 86
By connecting Art. 1256 in parallel to the terminals of bracket
5714KC the relay on the actuator can be controlled using the
dedicated pushbuttons on the monitor and/or telephone.
Actuator relay capacity: 10A. For use of Art. 1256, refer to
technical sheet FT SB2 02 of the same article.
Timed local door lock release connection variant
Diagram BK/OC
Page 86
DOOR OPEN signalling use variant
Diagram BK/OAC
Page 87
Connection of call repetition devices (Art. 1229 or
Art. 1122/A)
Diagram SB2/AAK
Page 87
The total number of internal units with the same user code and call
repetition devices connected to the above internal units cannot exceed
4. Connect only one call repetition device for each internal unit.
The MAX connection distance between the internal unit and call
repetition device is 20 m; use a screened cable for the
connection and do not run the cables near heavy inductive loads
or power cables (230V / 400V).
If inductive loads are connected, the connection of 470nF
capacitance in parallel with the C-NO contacts of Art. 1122/A is
advisable.
In case of audio interference induced by the connection of the
wires to terminals S+ S-, use Art. 1232 (see diagram GEN/AAB
on page 88).
Use Art. 1232 to filter induced interference on
terminals S+ and S-
Diagram GEN/AAB
Page 88
Variant A: addition of door call pushbutton
Page 88
A door call terminal can be added by connecting to terminals CFP
and CFP of bracket 5714KC.
The door call has a different tone from that of the external unit. In
case of several telephones or brackets with the same user code,
connect the CFP pushbutton to only one; all the devices will ring
simultaneously.
Use of pushbutton 1 for various purposes
Diagram BK/PC
Page 89
Variant for use of terminals LED + LED -
Diagram BK/NC
Page 89
Diagram for connecting 3 BRAVO KITS to main
entrance panel by means of Art. 4834/9
Diagram BK/EN/100C
Page 90
Diagram for connecting 30 BRAVO KITS (max.) to main
entrance panel with switchboard Art. 1998A (optional).
Bravo Kit branch from 1214KC
Diagram BK/EN/101C
Page 92
DESCRIPTION OF BRAVO KIT CONNECTION VARIANTS
Use of remote camera module Art. 1259C
Diagram BK/05C
Page 81
Connection of video amplifier Art. 4833C
Diagram SB2/AAR
Page 82
Addition of a main monitor in parallel
Diagram BK/HC
Page 82
Connection in cascade
The basic system can be extended to obtain a maximum of three
internal users for each Call button on the external unit. To add a
monitor, it is necessary to use Art. 5714KC (bracket), 5702 (monitor)
and power supply transformer Art. 1212/B. Set the microswitches
with the user code, according to the table on page 39.
Wire the two brackets with in/out cascade connection (see diagram)
or use the terminals 1214KC to branch from the riser (see diagram
BK/IC on page 83).
Diagram BK/IC
Page 83
Branch connection
Connection in cascade of a main monitor and a
secondary monitor with the same user code
Diagram BK/CC
Page 83
This diagram shows the possibility of connecting two monitors
(main and secondary) in cascade together and branching from
the riser with Art. 1214KC.
In this configuration, when a call is made from the external unit
only the main monitor switches on, and the secondary monitor
can be switched on by pressing Pushbutton 2 (video request).
When a call is made from the external unit the ringtone will sound
on both monitors.
Addition of an telephone in parallel with branch
connection from the riser
Diagram BK/DC
Page 84
Connection of additional telephones with branch
connection from monitor
Diagram BKC/AAB
Page 84
Connection of additional telephones with connection in
cascade from monitor
Diagram BKC/AAA
Page 85
Addition of external light control using Art. 1256
Diagram BK/EC
Page 85
When Art.1256 is installed in parallel on terminals LL of bracket
5714KC, the consent required to control an external lamp
synchronised with monitor switch-on can be obtained.
In this way, when a call is made, or upon automatic switch-on
command, the person at the external unit can be adequately
illuminated. For use of Art. 1256, refer to technical sheet FT SB2 02
of the same article.