Example:
on a monitor with user code 5, P1 programming = generic actuator, P2 = coded actuator (code 125)
1.
Set S2 DIP switch 6 to the combination 01.
»
the privacy LED flashes.
S2 DIP
1 2 3 4 5 6
0 0 0 0 0 1
S2
2.
Refer to the table on page
and select a combination in which the actuator function (ACT) is listed for the keys you
wish to program.
E.g.
: for P1= generic actuator, set S2 DIP switches 1-2-3-4 to the combination 0000 or 1100 or 0010 (P1=ACT), set S1 DIP
switches to the combination 11111111, go to point 3.
E.g.
: for P2= coded actuator (code 125), set S2 DIP switches 1-2-3-4 to the combination 0010 or 1010 (P2=ACT), set S1
with address 125 in accordance with
table A
13,
go to point 3.
3.
Press and release the key to be associated with the function.
»
the lock-release LED lights up.
»
a confirmation tone will sound.
4.
To exit programming mode, set S2 DIP switches 5-6 to the combination 00.
»
the privacy LED switches off.
5.
When programming is complete, set S2 DIP switches 1-2-3-4 to the combination 1111. Restore the user code
setting on S1, see table A on page
Programming keys for generic or coded actuator
Take note of the DIP-switch settings
DIP S2
Art. 6721W(/BM) + Art. 6734
DIP S1
DIP 1
DIP 2
DIP 3
DIP 4
P1
P2
P3
P4
P5
ADDRESS
0
0
0
0
ACT
1
0
0
0
0
1
0
0
ACT
1
1
0
0
ACT
0
0
1
0
ACT
ACT
ACT
ACT
ACT
ACT
1
0
1
0
ACT
0
1
1
0
1
1
1
0
0
0
0
1
1
0
0
1
0
1
0
1
ACT
1
1
0
1
ACT
0
0
1
1
ACT
1
0
1
1
0
1
1
1
1
1
1
1
PROG