18
3.9 Alarm
(This menu shows on only specific model, Fifth Item of Main menu)
ALARM SETUP
NO PRI PRS IN OUT HLD LATCH
01
1
001 OFF OFF 3
OFF
02
0
A01 OFF OUT1 3
OFF
03
1
080 NO OUT1 3
OFF
04
2
001 NC OUT1 3
OFF
SAVE AND EXIT(ESC TO CANCEL)
NO
: Alarm input number
PRIO
: Lower No. has higher priority, Equal priority alarms will be serviced repeatedly.
PRS
: Stored preset number to be called by alarm.
IN
: NO/NC - normally open /Closed OFF - ignore
OUT
: OUT1 - Relay out 1, OFF - No output.
HOLD : Alarm will be held for programmed time (03 to 99 seconds)
LATCH : ON - Shows all alarms including past alarm, OFF - Shows activated alarms only.
There are 4 levels of priority. “0” is the highest priority and can be selected Autoscan, Pattern or
Tour only. The other priority can be selected Preset only. During responding “0” priority alarm,
other alarms won’t be serviced until the “0” priority action is completed.
1. Press Menu to display the main menu on the monitor. Select the Alarm option by pushing
the Joystick up or down and push to right to enter the detail menu.
2. Select the alarm input number by pushing the Joystick up or down and select the column
you wish to setup. Selected position will be highlighted.
3. Select the Preset, Status of Input (NC/NO/OFF), and Output (OUT1/OFF) by pushing the
Joystick to the right or to the left.
4. To increase or decrease the preset number or to change the status or output number, twist the
Joystick clockwise or counterclockwise. In case of preset, programmed preset number
will be scrolled.
5. Select the Save and Exit option by pushing the Joystick up or down. Save and exit the
program by pushing the Joystick to the right. Press ESC to exit the program without saving.
Summary of Contents for 40799