background image

4

Relay codes: first programming

To program the relay codes, you must first know the supercode. The red LED on the keypad stays on during the programming 

procedure. 

In case of error, it flashes briefly and then turns off, after which you must start again from the beginning of the procedure.

Relay codes: first programming procedure
 1. 

Enter “

0

” and “

E

” (start programming procedure code).

 2. 

Check that the red LED has lit up.

 3. 

Enter the 

supercode

 followed by “

E

”.

 4. 

Enter the relay ID 

number

 (1 or 2) followed by “

E

”.

 5. 

Enter the operating mode (see 

"Bistable/Monostable operation"

), then “

E

”.

 6. 

Enter the new code followed by “

E

”.

 7. 

The LED should now turn off.

Example
To enter code 55127 for relay 1 in bistable mode (on/off), make the following keystrokes:

• 

0 E 

start procedure

• 

12345 E  supercode

• 

1 E 

relay 1 ID

• 

O E 

bistable operating mode

• 

55127 E  new cod

Using relay codes

Using relay codes After programming is completed, you can activate relay 1 by simply entering: 55127 E. In this example, the 

operating mode has been set to 0, in other words, bistable (on/off).
To activate monostable operation, see 

"Bistable/Monostable operation"

.

Up to 400 codes can be set relay 1 or relay 2.  

If you attempt to enter a code which has already been stored, an error is indicated.

The following procedure cancels stored codes from memory:

 1. 

Enter “

0

” and “

E

” (start programming procedure code).

 2. 

Check that the red LED has lit up.

 3. 

Enter the supercode (see 

"Entering the supercode"

), followed by “

E

”.

 4. 

Enter “

0

” (cancel code) followed by “

E

”.

 5. 

Enter the 

code

 to be cancelled, followed by “

E

”.

 6. 

The LED should now turn off.

Cancelling relay codes

Example
To cancel code 55127, enter in sequence:

• 

0 E 

start procedure

• 

12345 E  supercode

• 

0 E 

cancel

• 

55127 E  code to be cancelled

• 

If you make an error in entering the code, press the “key” 

 button several times to cancel the operation.

• 

You must always enter “E” at the end of the operation, whether during programming or normal use.

• 

Modifying or changing the supercode resets all other programmed settings (including relay codes).

• 

The supercode cannot be reset to a default value, but only replaced.

Summary of Contents for 3348B

Page 1: ...EN PROGRAMMING MANUAL Digital electronic key module Art 3348B 3348BM Passion Technology Design...

Page 2: ...first programming 4 Using relay codes 4 Cancelling relay codes 4 Bistable Monostable operation 5 Anti coercion function 5 Programming the allowed errors number 6 Programming the relay 1 activation del...

Page 3: ...supercode is the first operation because all subsequent steps depend on it We recommend using a short easy to remember supercode or noting it down on a sheet of paper Procedura di inserimento del supe...

Page 4: ...entering 55127 E In this example the operating mode has been set to 0 in other words bistable on off To activate monostable operation see Bistable Monostable operation Up to 400 codes can be set rela...

Page 5: ...off Example To set an anti coercion code of 3 enter in sequence 0 E start procedure 12345 E supercode 4 E anti coercion function 3 E anti coercion code Example If relay 1 was activated with code 55127...

Page 6: ...9 but DO NOT enter E 6 Enter 1 E to send an alarm when the key is locked 0 E if you do not wish to send an alarm 7 The LED should now turn off Example To set the activation time to 10 seconds enter i...

Page 7: ...uiting terminals CK and for example via a timer makes it possible to activate relay 1 without entering the relay code but by simply pressing the key button REMOTE KEY INPUT RK Closing this contact wit...

Page 8: ...Yes Contact capacity 24V AC DC MAX Service output max 100 mA Switch Switch C on the back of the module for selecting the LED lighting colour Leave the switch set to OFF for Simplebus systems Operatin...

Page 9: ...9...

Page 10: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy 1 ST edition 07 2017 code 2G40001935 C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Reviews: