3
Programming and operation
There is a timeout for programming procedures after which the operation is cancelled (around 40” between successive
keystrokes); we recommend familiarising yourself with the procedure before starting it.
Entering the supercode
Example
To enter supercode 12345, proceed as follows:
•
move the jumper to the ON programming position;
•
connect the module to the corresponding wired and powered terminal;
•
enter in sequence 1 2 3 4 5 E;
•
wait for 10 seconds or for the confirm tone to sound;
•
move the programming jumper to its previous OFF position.
Description
Art. 3348B / 3348BM for mounting in iKall modular keypads for mixed access control - entry panel - video entry panel
installations or stand-alone applications.
Programming the supercode is the first operation, because all subsequent steps depend on it.
We recommend using a short, easy to remember supercode, or noting it down on a sheet of paper.
Procedura di inserimento del supercodice
1.
Move jumper to the ON position (see figure).
2.
Connect the module to the corresponding wired and powered terminal.
3.
Check that the red LED has lit up.
4.
Enter the supercode (1 to 8 digits).
5.
Press “
E
” to store the code.
6.
Wait for 10 seconds or for the confirm tone to sound.
7.
Move jumper to the OFF position (see figure).
3
1
OFF ON
2
1.
Jumper for entering supercode
2.
Connector to be used for connection to Simplebus system.
3.
Switch for selecting the LED lighting colour. Leave the switch set to OFF for Simplebus systems
TERMINAL BLOCK - DESCRIPTION
~ – ~ +
power supply 12V DC/AC
CK
“key” button enable input
AL+
alarm and anti-coercion output, max. 100 mA
NO2 – C2– NC2
relay 2
NO1 – C1– NC1
relay 1
–
negative
RK
remote key input
D+ D–
RS 485 line connection