Config:
Select the required state in setting columns of RF information window for RF switch, then press [ON] or
[OFF] button to finish the configuration operation.
Alarm Threshold
Users can set alarm threshold according to the specific situation. If the measured value is lower than the
threshold lower limit or more than the threshold upper limit, the appropriate alarm will be generated.
Figure 55: MU Alarm Threshold
Figure 56: RU Alarm Threshold
Config:
Enter the required value in setting columns of RF information window for Alarm threshold, and press
[Enter] or [Config] button to finish the configuration operation.
Power
Users can read downlink output power of each frequency band in RF information window for Power.