Introduction

Congratulations 

With the installation of the 

Comar Electrical Services AUTO SHORE 

unit you 

have the ability to automatically boost low dock voltage insuring the supply of 
usable voltage from virtually any dock. 

The unit also provides protection from excessively high and excessively low dock 
voltage and provides isolation to combat electrolysis a nd reduce personal shock 
hazard. 

Summary of Contents for 50-120-240

Page 1: ...ual Revision 1 08 NA Model No 50 120 240 60Hz 50 Amp AutoShore Comar Electrical Services Ltd 114 1515 Broadway Street Port Coquitlam BC Canada V3C 6M2 Tel 604 941 7646 Fax 604 941 7610 Email info comarelectric com ...

Page 2: ...Table of Contents Pg 3 Pg 4 Pg 5 Pg 6 Pg 7 Pg 8 Important Safety Instructions Introduction Description of Operation Installation Specifications Performance Graphs Limited Warranty Pg 9 ...

Page 3: ...Switching voltage selector switch to off does not completely isolate control wiring To do so disconnect shore cable at dock and switch main breaker off 5 Warning Install transformer in a well ventilated location Do not store materials particularly flammable material on or around transformer 6 No terminals or lugs are required for hook up of the AC wiring AC wiring should be no less than No 6 AWG c...

Page 4: ...E unit you have the ability to automatically boost low dock voltage insuring the supply of usable voltage from virtually any dock The unit also provides protection from excessively high and excessively low dock voltage and provides isolation to combat electrolysis and reduce personal shock hazard ...

Page 5: ...voltage has to drop to at least 262 volts before the unit can be reset by pushing the lit reset button on the front of the panel 4 For the unit to trip due to low voltage input shore voltage must be lower than 178 volts for 3 seconds The input shore voltage has to raise to at least 180 volts before the unit can be reset by pushing the lit reset button on the front of the control panel The unit wil...

Page 6: ...ng diagram for proper installation Temp Sense Transformer Shore Receptacle Control Box Output to Ships Distribution Note A Circuit Breaker may be required between the Shore Receptacle and Control Box Consults local codes and regulations ...

Page 7: ...W Transformer 18 x 12 x 18 W x D x H Transformer weight 267 pounds ABYC ISOLATION OF GALVANIC CURRENTS 8 20 1 A metallic shield shall be located between the primary and secondary windings and be electrically insulated from all other portions of the transformer It shall be designed to withstand without leakage a high potential test of 4000 volts 60 Hz for one minute applied between the shield and a...

Page 8: ...8 Performance Graph ...

Page 9: ...the defective product is returned to any Comar Electrical Services authorized warranty repair facility or to the Comar Electrical Services factory in the original packaging with all transportation costs and full insurance paid by the purchaser or owner ALL REMEDIES AND THE MEASURE OF DAMAGES ARE LIMITED TO THE ABOVE COMAR ELECTRICAL SERVICES SHALL IN NO EVENT BY LIABLE FOR CONSEQUENTIAL INCIDENTAL...