Important Safety Instructions

Save these instructions 

General Precautions 

1.

Before using the AutoShore, read all instructions and cautionary
markings on (1) AutoShore control box and (2) transformer.

2.

Do not expose AutoShore to rain, snow or moisture of any type.

3.

Do not disassemble the AutoShore; have only a qualified electrician
perform service or repairs.  Incorrect re-assembly may result in a risk
of electric shock or fire. 

4.

To reduce risk of electric shock, disconnect all wiring before attempting
any maintenance or cleaning.  Turning off controls will not reduce this
risk.   Warning:  Switching voltage selector switch to off does not 
completely isolate control wiring.  To do so, disconnect shore cable at
dock and switch main breaker off.

5.

Warning.  

Install transformer in a well-ventilated location.  Do not store

materials (particularly flammable material) on or around transformer.

6.

No terminals or lugs are required for hook-up of the AC wiring.  AC
wiring should be no less than No. 6 (AWG) copper wire rated at least
90 degrees C.

7.

Over current protection for the AC output wiring is provided as an
integral part of this unit.  Over current protection of the AC input wiring
may be also required adjacent to shore inlet. Consult local regulations.

GROUNDING INSTRUCTIONS – Remove jumper between neutral and boat 
ground only if neutral is grounded at a common point in ship’s wiring.

 

Summary of Contents for 50-120-240

Page 1: ...ual Revision 1 08 NA Model No 50 120 240 60Hz 50 Amp AutoShore Comar Electrical Services Ltd 114 1515 Broadway Street Port Coquitlam BC Canada V3C 6M2 Tel 604 941 7646 Fax 604 941 7610 Email info comarelectric com ...

Page 2: ...Table of Contents Pg 3 Pg 4 Pg 5 Pg 6 Pg 7 Pg 8 Important Safety Instructions Introduction Description of Operation Installation Specifications Performance Graphs Limited Warranty Pg 9 ...

Page 3: ...Switching voltage selector switch to off does not completely isolate control wiring To do so disconnect shore cable at dock and switch main breaker off 5 Warning Install transformer in a well ventilated location Do not store materials particularly flammable material on or around transformer 6 No terminals or lugs are required for hook up of the AC wiring AC wiring should be no less than No 6 AWG c...

Page 4: ...E unit you have the ability to automatically boost low dock voltage insuring the supply of usable voltage from virtually any dock The unit also provides protection from excessively high and excessively low dock voltage and provides isolation to combat electrolysis and reduce personal shock hazard ...

Page 5: ...voltage has to drop to at least 262 volts before the unit can be reset by pushing the lit reset button on the front of the panel 4 For the unit to trip due to low voltage input shore voltage must be lower than 178 volts for 3 seconds The input shore voltage has to raise to at least 180 volts before the unit can be reset by pushing the lit reset button on the front of the control panel The unit wil...

Page 6: ...ng diagram for proper installation Temp Sense Transformer Shore Receptacle Control Box Output to Ships Distribution Note A Circuit Breaker may be required between the Shore Receptacle and Control Box Consults local codes and regulations ...

Page 7: ...W Transformer 18 x 12 x 18 W x D x H Transformer weight 267 pounds ABYC ISOLATION OF GALVANIC CURRENTS 8 20 1 A metallic shield shall be located between the primary and secondary windings and be electrically insulated from all other portions of the transformer It shall be designed to withstand without leakage a high potential test of 4000 volts 60 Hz for one minute applied between the shield and a...

Page 8: ...8 Performance Graph ...

Page 9: ...the defective product is returned to any Comar Electrical Services authorized warranty repair facility or to the Comar Electrical Services factory in the original packaging with all transportation costs and full insurance paid by the purchaser or owner ALL REMEDIES AND THE MEASURE OF DAMAGES ARE LIMITED TO THE ABOVE COMAR ELECTRICAL SERVICES SHALL IN NO EVENT BY LIABLE FOR CONSEQUENTIAL INCIDENTAL...