5 Technical data
The device is intended to be used in the engine room or on the engine directly.
Value
Controller
IV5 Display
Voltage supply
8-36V DC
8-36V DC
Consumption depends on supply voltage
1,1A at 8VDC
0,7A at 8 VDC
Power supply
Note:
InteliVision 5 and the control unit should be used the same battery source. When external battery is
needed because of long wiring and etc.. InteliVision 5 RD is recommended to use.
Operating temperature
-40 ˚C to +70 ˚C
Storage temperature
-30 ˚C to +80 ˚C
Flash memory data retention
time
10 years
Protection front panel
IP 65
Operating humidity
85% without condensationIEC/EN 60068-2-30
Operating conditions
Low Voltage Directive
EN 61010-1:95 +A1:97
Electromagnetic Compatibility
EN 61000-6-3
EN 61000-6-4
EN 61000-6-1
EN 61000-6-2
Vibration
EN 60068-2-6
Standard Conformity
Dimensions
Front panel 245x164mm
InteliVision 5 cutout 175x115mm
Weight
855g
Dimensions and Weight
Maximal distance 1000m (depends on local conditions and interference)
* RS 485 is galvanicaly separated
Speed up to 57.6kBd
Communication Interface
5.7" color TFT display with resolution of 320 × 240 pixels
LCD display active area dimension 115,2 x 86,4mm
Pixel size 0.120(W) x 0.360(H) mm
LCD Display
Note:
* RS-485 interface is galvanicaly separated from the serial number 1511434C (HW version on the back sticker
is 1.2)