4.3 Dimensions drawings

Image 4.4 Dimensions of the InteliVision 18Touch

4.4 Mounting

IV18T is designed to mount onto the panel. IV18T has an integrated mounting system. The recommended

cutout size for panel mounting is 472,4 mm (width) x 302,2 mm (height). Insert IV18T into the cut area and from

the rear side install the attached mounting clips and fix them with a screwdriver.

Summary of Contents for InteliVision 18Touch

Page 1: ...l com www comap control com Global Guide InteliVision 18Touch 18 5 display unit for ComAp controllers SW version 1 0 1 Document information 4 2 System overview 8 3 Technical data 9 4 Installation and wiring 10 5 Display Unit Settings 20 6 InteliVision 18Touch connection possibilities 21 7 Automatic SCADA start and connecting to the system 28 8 Creating a SCADA diagram 29 ...

Page 2: ... 10 4 2 Rear panel description 11 4 2 1 Rear Top 11 4 2 2 Rear Bottom 12 4 3 Dimensions drawings 13 4 4 Mounting 13 4 5 Power 14 4 6 Ethernet LAN Ports 15 4 6 1 LAN1 Port 15 4 6 2 LAN2 Port 15 4 7 COM Ports 17 4 7 1 COM1 Port 17 4 7 2 COM2 Port 17 4 7 3 COM Port Mode 18 5 Display Unit Settings 20 5 1 Touchscreen settings 20 5 2 On Screen Keyboard OSK settings 20 6 InteliVision 18Touch connection p...

Page 3: ...24 6 2 2 Multiple Ethernet Connection 25 6 2 3 Ethernet Internet connection via InternetBridge NT 26 7 Automatic SCADA start and connecting to the system 28 8 Creating a SCADA diagram 29 8 1 Automatic SCADA generating 29 8 2 User defined SCADA layout 31 8 2 1 Preparing SCADA archives 31 8 2 2 Creating SCADA on another PC 32 ...

Page 4: ...e part of ComAp s Product and may be used exclusively according to the conditions defined in the END USER or Distributor LICENSE AGREEMENT CONDITIONS COMAP CONTROL SYSTEMS SOFTWARE License Agreement and or in the ComAp a s Global terms and conditions for sale of Products and provision of Services Terms and or in the Standardní podmínky projektů komplexního řešení ke smlouvě o dílo Standard Conditi...

Page 5: ... However ComAp is prepared to provide technical support to resolve problems arising from such actions including but not limited to restoring settings prior to the cyber attacks backing up data recommending other preventive measures against any further attacks Warning Some forms of technical support may be provided against payment There is no legal or factual entitlement for technical services prov...

Page 6: ...e interference take adequate measures at their own expense UL This product is Listed by UL Representative samples of this product have been evaluated by UL and meet applicable safety standards 1 Battery used only CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS ATTENTION IL Y A RISQUE D EXPLOSION SI LA BATTERIE EST REMPLA...

Page 7: ... NTC BB InteliGenNT Complex Parallel Gen set Controller IG NT GC InteliSysNTC Hybrid Hybrid system controller IS NTC HYBRID InteliMainsNT Mains Supervision Controller IM NT GC InteliDrive DCU Marine Modular Certified Engine Controller for Marine Applications ID DCU MARINE InteliGenNTBaseBox Complex Parallel Gen set Controller with Detachable Colour Display IG NT BB InteliLiteNT Manual Remote Start...

Page 8: ...allation with large numbers of measured values CHP Combined Heat and Power Optimized for ease of installation configuration and use the touchscreen allows users to create touch buttons linked to another screen with the option of directly controlling gen sets or breakers InteliVision 18Touch communicates over standard interfaces such as RS232 485 Ethernet USB InteliVision 18Touch comes with PC SCAD...

Page 9: ...O 2 x RS232 422 485 2 x USB 2 0 1 x USB 3 0 VGA port 1 x DB15 Audio port 1x Line out Ethernet 10 100 1000 Base Tx 2 x RJ45 Interfaces CPU Intel Celeron quad core J1900 2 0 GHz 2 42 GHz turbo boost Memory 4GB RAM Storage Device 1x 32 GB Solid state drive 1x External locked CFast socket Expansion 2 x mini PCIe sockets support optional Wi Fi 3 5G module or fieldbus card System LCD panel 18 5 TFT LCD ...

Page 10: ...and wiring 4 1 Front panel description 10 4 2 Rear panel description 11 4 3 Dimensions drawings 13 4 4 Mounting 13 4 5 Power 14 4 6 Ethernet LAN Ports 15 4 7 COM Ports 17 6 back to Table of contents 4 1 Front panel description Image 4 1 Front panel overview ...

Page 11: ...al antenna holes are used to mount and connect optional 3 5G Wi Fi antennas CFast CFast Card Socket Used to insert a CFast card Power switch Press to power on or power off the panel PC Backlight on off Press to turn on or turn off the display Increase Brightness Press to increase brightness of the screen Decrease Brightness Press to decrease brightness of the screen ...

Page 12: ...the system LAN1 LAN2 Used to connect the system to a local area network LAN1 supports Wake up on LAN USB 2 0 Used to connect USB 2 0 1 1 devices USB 3 0 USB 3 0 port to connect the system with USB 3 0 2 0 devices COM1 COM2 These COM ports support RS232 422 485 compatible series device through BIOS setting and have 2 5kV isolated protection Reset Button Press this button to restart the system VGA U...

Page 13: ...18Touch 4 4 Mounting IV18T is designed to mount onto the panel IV18T has an integrated mounting system The recommended cutout size for panel mounting is 472 4 mm width x 302 2 mm height Insert IV18T into the cut area and from the rear side install the attached mounting clips and fix them with a screwdriver ...

Page 14: ...negative supply voltage pin is connected to the IV18T chassis internally Ensure correct polarity when connecting the DC power supply PIN Definition 1 DC Positive supply voltage 2 DC Negative supply voltage 3 GND Ground Table 4 1 Description of Power connector IMPORTANT Do NOT connect power between pins GND and DC IT WILL CAUSE UNREPAIRABLE DAMAGE OF THE DISPLAY UNIT Table 4 1 shows the consumption...

Page 15: ...5 LAN1M2N 6 LAN1M1N 7 LAN1M3P 8 LAN1M3N Table 4 3 Pin description of LAN1 Port on InteliVision 18Touch ACT Status Flashing yellow Data activity Off No activity Table 4 4 ACT Status description table LINK Status Steady Green 1G network link Steady Orange 100Mbps network link Off 10Mbps or no link Table 4 5 LINK Status description table 4 6 2 LAN2 Port Support Wake on LAN WOL Connector type RJ45 por...

Page 16: ...LAN1M1N 7 LAN1M3P 8 LAN1M3N Table 4 6 Pin description of LAN1 Port on InteliVision 18Touch ACT Status Flashing yellow Data activity Off No activity Table 4 7 ACT Status description table LINK Status Steady Green 1G network link Steady Orange 100Mbps network link Off 10Mbps or no link Table 4 8 LINK Status description table ...

Page 17: ...ND COM1_GND Reserve 6 COM1_DSR COM1_RTS Reserve 7 COM1_RTS COM1_RTS Reserve 8 COM1_CTS COM1_CTS Reserve 9 COM1_RI Could be a 5V Power Pin COM1_CTS Could be a 5V Power Pin Reserve Could be a 5V Power Pin Image 4 5 Pin description of COM1 Port on InteliVision 18Touch 4 7 2 COM2 Port Connector type DB 9 port 9 pin D Sub Pin RS232 RS422 RS485 1 COM1_DCD COM1_TXD COM1_TXD COM1_RXD 2 COM1_RXD COM1_TXD C...

Page 18: ...ailor your system to suit your individual work needs It is a ROM based configuration utility that displays the system s configuration status and provides you with a tool to set system parameters These parameters are stored in non volatile battery backed up CMOS RAM that saves this information even when the power is turned off When the system is turned back on the system is configured with the valu...

Page 19: ...ng BIOS setup Serial Port Enables or disables the serial port Onboard Serial Port Mode Select this to change the serial port mode to RS232 RS422 RS485 or RS485 Auto Terminal Resistor Enables or disables the terminal resistor IMPORTANT Only experinced user should do the BIOS changes ...

Page 20: ...n is predefined with no password set You can restrict users by setting passwords and or creating new users with limited rights For more details use Windows help 5 1 Touchscreen settings It is possible to calibrate touch sensor using the standard Microsoft Windows 7 functions 1 Navigate to Start Control Panel Tablet PC Settings Calibration 2 Perform the calibration 3 Save the calibrate data 4 Done ...

Page 21: ...Ap controllers 6 back to Table of contents 6 1 IV18T connection to a Single gen set 6 1 1 RS 232 connection Image 6 1 Point to point RS 232 connection to the IV18T IV18T settings Controller settings 2 x RS 232 serial ports additional settings Setpoints Comms settings group RS232 1 mode DIRECT additional settings Table 6 1 Communication settings for the IV18T and controller Note It is also possible...

Page 22: ...ee the chapter Connection via I LB or IB NT 6 1 3 Ethernet direct connection Many different kinds of Ethernet topologies exist A basic point to point Ethernet connection can be made by a direct or cross Ethernet cable In addition it is also possible to monitor more than one controller in a site through a switch TCP IP protocol based network Another possibility is establishing a connection through ...

Page 23: ...eb browser e g http 192 168 1 254 and then enter the access code When connecting through a web browser there is 5 minute timeout period after closing the browser window After that the client is automatically logged out Ethernet connection settings Settings can be edited via any type of connection USB RS 232 RS 485 or Ethernet Setup is provided via InteliMonitor For the Ethernet connection set the ...

Page 24: ...de instead of CAN2 I LB hardware setup All jumpers in these positions HW SW control Does not matter ComAp ModBus Open ADDR1 ADDR2 Selection of CAN address Open ADDR1 Close ADDR2 It is possible to use up to two I LB devices in direct mode on the CAN 2 bus Leave the jumper open when using one I LB module The other I LB module has to have this jumper closed See I LB module for further details DIRECT ...

Page 25: ...face IP setting necessary see Image 6 4 Table 6 5 Communication settings of IV18T and controller Note An Ethernet connection is also available for all above mentioned controllers via an external Bridge IB NT See the chapter Ethernet connection via IB NT You can also use IB NT without the need for a Public IP address find more information about our AirGate technology on our website www comap contro...

Page 26: ...fic and must provide port forwarding from the external public IP to the various internal gen set IPs according to the port used Image 6 8 Internet gateway router configuration example 6 2 3 Ethernet Internet connection via InternetBridge NT Up to 32 controllers can be remotely monitored via a single InternetBridge NT The response time of a system with this type of connection depends on the number ...

Page 27: ...ge 6 9 IB NT connection example Note For more information about setting the InternetBridge NT see IB NT 1 0 Reference Guide pdf which can be downloaded from our website www comap control com 6 back to InteliVision 18Touch connection possibilities ...

Page 28: ...SCADA automatic start example When the IV18T boots up InteliMonitor will automatically start and connect to the predefined site By enabling the function Fullscreen mode InteliMonitor will start in fullscreen mode Note You can easily secure your fullscreen SCADA by setting a password in the SCADA tab Another setting in the same SCADA tab is Touch panel mode which opens the embedded alphanumeric Int...

Page 29: ...ect the IV18T to the system start InteliMonitor select Open connection and create a new Site Select Site properties and choose the appropriate options for your site topology Uncheck the box Disable automatic rendering of single line diagram Image 8 1 Site properties Add all controllers available in the system and their properties Image 8 2 Controllers settings Choose the connection type used for c...

Page 30: ...iVision 18Touch 1 0 Global Guide 30 Image 8 3 Connection settings Select Open connection A site diagram will be generated during the connection process Image 8 4 Automatically generated SCADA diagram example ...

Page 31: ...l buttons Meters Breakers Bar graphs Trends data grids with binary analog values Link buttons 8 2 1 Preparing SCADA archives Physically connect the IV18T to the system start InteliMonitor select Open connection and create a new Site Select Site properties and choose the appropriate options for your site topology Enable the box Disable automatic rendering of single line diagram Image 8 5 Site prope...

Page 32: ... procedure to create a SCADA on any PC or laptop Use the procedure from the previous chapter to save valid archives Use the Export site to file function located in the Open connection window to create a ZIP archive for the previously created site highlight it press and enter the name and location of the ZIP file it is best to save it directly to a flash drive After that you can disconnect from the...

Page 33: ... Communication object number directly but it is more convenient to click on the button to the right and choose the object from the list You may be asked for an archive with a valid configuration If you use images it is strongly recommended to copy all images used into the root of your site folder Do not create any subfolders under your site Linked screens SCADA supports multiple screens e g with d...

Page 34: ...n window in the Sites section under the button Image 8 9 Site properties If everything is OK save all data If you have prepared screens offline close the offline archive on laptop Click on Open and in the Open connection window select your site and click Export site to file Save the ZIP file to the flash disk insert this flash disk into the IV18T and on the IV18T use Import site from file Select t...

Reviews: