InteliDrive DCU Marine - 3.0.0 Global Guide
178
Note:
When Remote Lock is active, it is still possible to initiate programming of a remotely connected
InteliMonitor.
Related FW
3.0.0
Related applications
All
Comm object
5
Description
Active Binary input switches ID-DCU MARINE display backlight between two adjustable intensity levels.
Alternative intensity of the backlight can be set independently by ID-DCU MARINE panel buttons:
1. Hold Enter and press Page to switch to ID Info screen (from any measure screen)
2. Hold Enter and pres / ¯ arrow key to increase/decrease display brightness
The adjusted intensity is stored in non-volatile memory.
Note:
Both backlight levels are default (from production) set to maximum.
Low Brightness
Related FW
3.0.0
Related applications
All
Comm object
16
Description
Active input blocks protections that are configured as “Force Block 1” Prot. block type. Corresponding
setpoint is ForceBlockDel1.
Force Block 1
Related FW
3.0.0
Related applications
All
Comm object
17
Description
Active input blocks protections that are configured as “Force Block 2” Prot. block type. Corresponding
setpoint is ForceBlockDel2.
Force Block 2
Related FW
3.0.0
Related applications
All
Comm object
18
Description
Active input blocks protections that are configured as “Force Block 3” Prot. block type. Corresponding
setpoint is ForceBlockDel3.
Force Block 3
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...