background image

Single brush machine 

 

 

E 505 S Ex 
 

  

 

 

The Columbus E 505 S Ex single brush machine is an electric device according to the 
ATEX 2014/34/EU, conforming to Appliance Category II 2G (Zone 1 and Zone 2), 
suitable for the Material Groups IIA to IIC according to EN 60079 with Temperature Class 
T3 (195 °C). The admissible ambient temperature lim its are +10 °C to +40 °C. 

 

 

Attention: If the appliance is left in the sun for longer periods of time, the housing surfaces of the 
appliance components may become too hot. 

 
Please monitor these conditions for the single brush machine constantly to ensure that the appliance is only used 
within the specified ranges. Only the components (cleaning tools) specified by the manufacturer may be used. 
The use of other tools is not permitted and can cause an explosion. 
Only use non-flammable chemical additives. 
The Columbus E 505 S Ex single brush machine, conforming to EN 60’529, Class IP 55, may not be stored 
outside over a longer period of time. The machine may be used in light rain but be sure to dry the appliance 
thoroughly after use. 
The Columbus E 505 S Ex single brush machine must only be used for the purpose intended. Proper use implies 
compliance with the instructions contained in the manufacturer’s operating, maintenance and repair manuals. 
The Columbus E 505 S Ex single brush machine must only be used by properly trained staff, i.e. with the 
authorization of the owner of the appliance. The Columbus E 505 S Ex single brush machine must only be 
maintained or repaired by properly trained persons approved by the manufacturer, or by the manufacturer 
himself. 
The local accident prevention regulations which apply and other generally recognized health & work safety 
regulations must be observed. Unauthorized changes, modifications etc. to the single brush machine nullify 
entirely any liability of the manufacturer, including for any damage which may result. 
 

1.5. Product liability 

The attention of the operator or owner of the Columbus E 505 S Ex single brush machine is expressly drawn to 
the fact that the appliance may only be used for the intended purpose and be maintained by the manufacturer, & 
Co. Columbus Cleaning Machines, 70372 Stuttgart, Germany, according to his specifications. 
In case the machine is not properly used, this is the sole responsibility of the machine operator and any liability 
of the single brush machine manufacturer will cease. 
 

1.6. Sources of dangers 

Always avoid any risk of running over the power supply cable. There may be danger of a fatal accident 
occurring or risk of an explosion, if the power cable is run over by the rotating scrubbing brush or becomes 
entangled. Under no circumstances may the appliance be placed on top of the power cable. 
Never switch the machine with on the handle in the vertical position, as it is impossible to apply enough 
holding force in this position, due to the too short leverage distance (counter-torque). 
The single brush machine is only intended for use on flat surfaces with a maximum gradient of 2 %. Never 
use the single brush machine in heavy rain. It is also recommended not to use the appliance for cleaning 
(scrubbing) in puddles (water-level max. 10 mm). 
 

1.7. Special safety instructions 

To prevent damage, subsequent damage or any other kind of damage due to technical malfunction of the 
Columbus E 505 S Ex single brush machine if a technical fault occurs, it must be switched off immediately and 
disconnected from the power supply. Drive cautiously over any thresholds or steps to avoid damage to the 
single brush machine, e.g. damage to the scrubbing brush, the gears or the wheels. 

5

Summary of Contents for E 505 S Ex

Page 1: ...505 S Ex Read these instructions carefully before operating the machine Operating Manual Single brush machine and Accessories 01 2020 This machine is intended for industrial and professional use only...

Page 2: ...Delivery 6 4 Inserting the cleaning tool 6 5 Starting the single brush machine 7 6 Equipment for floor cleaning and maintenance 9 7 Transporting the single brush machine 9 8 On finishing work 9 9 Care...

Page 3: ...umbers 1 Handle bar 10 Wheel 2 Positioning lever 11 Carrying handle 3 Control lever 12 Machine body 4 Switch housing 13 Cleaning tool 5 Handle 14 Drive disc 6 Mains plug 15 Cable hook 7 Control unit 1...

Page 4: ...ges e g scouring marks wear s unplug the machine before carrying out any care maintenance or repair work or before changing the scrubbing brush Do not use the single brush machine when the connecting...

Page 5: ...afety regulations must be observed Unauthorized changes modifications etc to the single brush machine nullify entirely any liability of the manufacturer including for any damage which may result 1 5 P...

Page 6: ...hard surfaces especially inside buildings The Columbus E 505 S Ex single brush machine must only be used with the cleaning tools shown in point 6 and point 1 4 3 Delivery The Columbus E 505 S Ex sing...

Page 7: ...rclockwise Then snap the cleaning tool into place and check the appliance for e g imbalance vibration unwanted noise etc The appliance is ready for use if no faults have been detected and if there is...

Page 8: ...ion i e the resistance of the handle s rotating joint can be adjusted as required To do this first undo the lock nut at the end of the set screw using an SW 13 spanner To do this hold the set screw wi...

Page 9: ...mains plug 6 straight away and wind the cable carefully round the cable hook 15 provided for this purpose and the handle 1 The cleaning tool 13 should always be removed from the appliance Release the...

Page 10: ...ed personnel approved by the manufacture The machine must only be cleaned with a moistened cloth if necessary a mild detergent may be added The brush drive motor and the gearing of the machine are mai...

Page 11: ...and point 1 4 11 Technical data E 505 S Ex Remarks Rated voltage 380 400 V 50 Hz Rated power 1000 W Working height 50 cm Max working height 46 5 cm Brush speed 130 142 min 1 Surface pressure 0 38N cm...

Page 12: ...G Staehle GmbH u Co KG columbus Reinigungsmaschinen Mercedesstr 15 70339 STUTTGART Telefon 49 0 711 9544 950 Telefax 49 0 711 9544 94 info columbus clean com www columbus clean com 70097300...