Time Control
(optional)
A seven-day time clock, when furnished, provides Automatic Dual Pressure or Automatic
Off/On Operation, whichever is desired. An adjustable time switch makes one circuit and
breaks another simultaneously at as many intervals every 24 hours as required. See wiring
diagrams enclosed.
When used for On/Off operation, one side of the circuit is connected in series with the
pressure control. The other side is not used. On dual pressure operation an additional pres-
sure control is connected in series, on one side of the time switch.