Y Series TechBook
29
Water temperature
regulation
In a regulation cycle,
the system first generates
water flow through the
heater housing and the
plumbing, in order to
ensure accurate water
temperature readings as
well as avoiding heater
activation in dry
conditions
The system verifies
periodically that all
parameters are within
normal range
Smart Winter Mode
Our Smart Winter Mode
protects your system
from the cold by turning
pumps on several times a
day to prevent water from
freezing in pipes
The
Smart Winter Mode
indicator lights up when
the Smart Winter Mode
is on
Cool down
After heating the spa water
to the desired Set Point,
the heater is turned off,
but its associated pump
(Pump 1 low-speed or CP)
remains on for a certain
amount of time to ensure
adequate cooling of the
heating element,
prolonging its life
The
Heater
icon flashes
during this time
If the readings received
from the system are not
valid, blanks (- - -) will be
displayed until normal
readings have been
successfully recorded
After verifying pump
activation and taking
a water temperature
reading if required, the
system automatically
turns the heater on to
reach and maintain water
temperature at Set Point
The
Heater
indicator lights
up when the heater is on
It flashes when there is
a request for more heat
but the heater has not yet
started
Typical settings
Adjustable Regulating Set Point:
59°F (15°C) to 104°F (40°C)
Factory Default Set Point:
Typical 95°F (35°C) / Max 100°F (38°C)
Filter Cycle Duration:
0 to 24 hrs / Factory set at 2hrs
Filter Cycle Frequency:
1 to 4 times a day / Factory set at 2
Filter Cycle Start:
00:00 to 23:59 / Factory set at 12:00
Pump Runtime:
1 to 255 min / Factory set at 20 min
Light Timeout:
1 to 255 min / Factory set at 120 min
ink200 (LED display, 4 keys,
8 light indicators)
ink600 (streamlined)
ink19
ink35
ink450 (LCD display,
6 keys, 10 function icons)
ink8
ink4
Keypads available for the Y Series:
ink800