background image

6700C Series

Sensor Operated Mixing Faucet

Control Module Settings

IMPORTANT: Always push the Reset Button after any adjustments

1

2

3

4

5

6

7

8

Factory Preset

= Switch Position

Shut Off Time Delay (After hands are removed)

Sw1

Sw2

Sw3

Delay

On

On

On

1 Sec

On

On 

Off

2 Sec

On

Off

On

3 Sec

On

Off

Off

4 Sec

Off

On

On

5 Sec

Off

On

Off

6 Sec

Off

Off

On

7 Sec

Off

Off

Off

8 Sec

Automatic Time Off (maximum run time after activation)

Sw4

Sw5

Time Off

On

On

OFF

On

Off

15 Sec

Off

On

30 Sec

Off

Off

60 Sec

Sensor Distance

Sw6

Mode

Distance

On

Std

4” - 12”

Off

Enhanced

10” - 12”

To increase distance, turn adjuster CLOCKWISE

To decrease distance, turn adjuster COUNTER-CLOCKWISE

Faucet Switch - DO NOT TOUCH

Sw7

Sw8

Mode

On

Off

Auto Faucet

6700C Series

Sensor Operated Mixing Faucet

Control Module Settings

IMPORTANT: Always push the Reset Button after any adjustments

1

2

3

4

5

6

7

8

Factory Preset

= Switch Position

Shut Off Time Delay (After hands are removed)

Sw1

Sw2

Sw3

Delay

On

On

On

1 Sec

On

On 

Off

2 Sec

On

Off

On

3 Sec

On

Off

Off

4 Sec

Off

On

On

5 Sec

Off

On

Off

6 Sec

Off

Off

On

7 Sec

Off

Off

Off

8 Sec

Automatic Time Off (maximum run time after activation)

Sw4

Sw5

Time Off

On

On

OFF

On

Off

15 Sec

Off

On

30 Sec

Off

Off

60 Sec

Sensor Distance

Sw6

Mode

Distance

On

Std

4” - 12”

Off

Enhanced

10” - 12”

To increase distance, turn adjuster CLOCKWISE

To decrease distance, turn adjuster COUNTER-CLOCKWISE

Faucet Switch - DO NOT TOUCH

Sw7

Sw8

Mode

On

Off

Auto Faucet

6700C Series

Sensor Operated Mixing Faucet

Control Module Settings

Settings Control Dipswitches

Reset Button

Sensor Length Adjuster

Summary of Contents for Sani-Lav 5A2A

Page 1: ...ia does not recommend use with harsh chemicals Product Compliance NSF ANSI 2 Food Equipment NSF ANSI 61 Section 9 ASME A112 18 1 ADA Compliant ADA Compliant Operating Manual for 2 Person Hands Free Wall Mount Stainless Steel Wash Station AC Models 5A2A and 5A2A 0 5 Battery Models 5A2B and 5A2B 0 5 ...

Page 2: ... 3 Remove support brackets from sink and drill holes for mounting fasteners not provided 4 Re mount support brackets to sink and fasten to wall Step 4 1 Connect waste line to strainer assembly s 2 Mount sensor control box at desired location on wall 3 Connect power line from sensor to control box 4 Attach supply tube from faucet to control box 5 Connect hot and cold water from the source to mixing...

Page 3: ...6 5 407mm 7 177 8mm 5 127mm 35 889mm suggested floor to rim height 5 R 12 7mm 437 6mm 75 19mm slot 437 6mm dia hole 875 22mm dia holes 2 1 5 38mm 2 51mm 1 5 38mm Hole Configurations Front Side Top 47 125 1197mm 45 1143mm 20 508mm 2 51mm 7 5 191mm 1 5 38mm 6 152 4mm 16 75 425 45 mm 2 drain hole 50 8mm 5 R 12 7mm Cross breaks to aid drainage 4 101 6mm Wall mounting brackets 2 51mm 875 22 22mm Back S...

Page 4: ...r environment Use a quality stainless steel cleaner and follow cleaner instructions Wipe along the grain NOT against Illustration D Things to Avoid Avoid harsh abrasive cleaners and corrosive chemicals Avoid abrasive scouring pads carbon steel brushes and steel wool for cleaning as iron particles left behind can lead to rust Avoid the use of oily rags or greasy cloths when wiping the surface To av...

Page 5: ... Plug in Input AC 120V 60 Hz or 220V UL CSA Output DC 12V 0 8A Class 2 Power Cable Armored vandal resistant Optional Multi Unit Adapter Serves up to 8 faucets UL CSA Input AC 120V Output DC 12V 3A Battery Mode Battery Powered Models 4 AA Alkaline Batteries Battery Service Life 400 000 on off cycles up to 4 years Package Includes 1 Faucet with electronic sensor 1 Control box w 6V DC solenoid 1 12V ...

Page 6: ...he sink wall and tighten the faucet onto the sink using the O Ring 8 Washer 9 and Mounting Nut 10 Attach the 90 Degree Elbow 11 to the Supply Rod 7 USE TEFLON TAPE ONLY NO PIPE DOPE 5 Reconnect the Sensor Eye Cable 17 and Power Adapter 19 connections described in STEP 2 making sure the cables are seating in the Control Box 18 housing properly 6 Attach the Compression Fitting 13 to the Solenoid Val...

Page 7: ...id In line filter is clogged Open clean out trap and check filter screen Clean or replace filter screen Solenoid coil is defective Insert new batteries or reattach power adapter Light blinks but no solenoid is clicking Replace solenoid coil Flow control is clogged Open flow control device and check Celan the flow control device Faucet will not shut off has low glow or drips The solenoid valve is n...

Page 8: ...ring 6 Piston Piston Spring and check the Piston Sleeve for corrosion 6 Re install all parts in same order as the diagram below 7 Re install solenoid on the control box and re mount box in water line 8 Check and clean Filter Screen 24 in Filter Body 22 9 Reset P C Board and make sure solenoid clicks open and thumps closed 10 Turn on water and check for leaks and proper operation For further questi...

Page 9: ...CH Sw7 Sw8 Mode On Off Auto Faucet 6700C Series Sensor Operated Mixing Faucet Control Module Settings IMPORTANT Always push the Reset Button after any adjustments 1 2 3 4 5 6 7 8 Factory Preset Switch Position Shut Off Time Delay After hands are removed Sw1 Sw2 Sw3 Delay On On On 1 Sec On On Off 2 Sec On Off On 3 Sec On Off Off 4 Sec Off On On 5 Sec Off On Off 6 Sec Off Off On 7 Sec Off Off Off 8 ...