35. Replace the 4 x M3 screws
in each corner of the PCB
Tray.
36. Rotate the scanner back
into position on the stand.
37. After powering up the scanner, go to the Set Parameters program as described in chapter
2 ‘Configuring Main Board’ and configure the main board to the scanner model (‘Reset
Flash Ci40’ or ‘Reset Flash Ci24’ depending on scanner type), the use the utilities program
and run the
normalise and autostitch, as well as resetting the motor speed to it’s original
value as was noted at the beginning of this procedure.