DMX Values
3 Channels Mode
Channel Value
Function
1
0-10
Spark Off
11-255
Spark On
2
0-149
No Effect
150-255 Clear Material (Blower only, no heat)
Recommended after each use.
3
0-199
Heating on (Ch1 functions will not work)
200-255 Stop heating (Ch1 functions will not work)
*NOTE:
The “Stop heating” function can be
useful when a machine needs to be part of
a live event setting for an extended time
while remaining cool.