Page | 33
Verve Hybrid
Vertical Check
The vertical alignment test is performed to check the vertical alignment of all heads with reference to the
Magenta head. To execute vertical alignment test, click on the
Vertical Check
button on the
Calibration
Wizard
.
Samples of Good and Bad Vertical Alignment Test Result is shown in the image below:
Fig 46: The Good and Bad Vertical Alignment Test Result
When a Print Head is aligned with the reference Print Head (Magenta), then in the test print this would be
evident by perfectly aligned vertical nozzle lines. In case of vertically misaligned Print Head, its nozzle lines
would be either above or below the reference head’s nozzle lines.
Similarly, check for other colors (Black,
Magenta, and Yellow) with the reference color (Magenta).
Note
: During the mechanical checks, it may possible that it will disturb the angle check or vertical check.
Thus, repeat the mechanical check until the perfect alignment condition is achieved.