Page
45
of
50
SOFTJET GRAND
3.
Regulator is set at Low and
Take-Up regulator not
working
Case 3:
Check the regulator settings and
rotate the knob to ON it. Additionally, if
regulator is not working, replace it.
Complete
Head Not
Firing
1.
Head voltage is not fed in
Printer Manager
2.
Head cable is not properly
connected with the Head
Board
3.
Head Board connectors are
not properly connected on
the Print Head
4.
Ink stains are visible on the
Head connector
5.
Head or Head Board or Main
Board is faulty
6.
Ink sub tanks are empty
Case 1:
Fed Head Voltage in Printer
Manager.
Case 2:
Check the Head cable and connect
it properly.
Case 3:
Check the connectors and connect
them properly.
Case 4:
Inform to the Head Office
Case 5:
Replace the Head or Head Board or
Main Board by contacting to the Head
Office.
Case 6:
Refill the Ink Sub tanks, if empty.
Negative
Pressure
Drop/Not
Working
1.
Meniscus vacuum switch is
OFF
2.
Negative Pressure switch
program is disturbed
3.
Vacuum is not generated by
pump (pump failure)
4.
Any ink/air tube is having
leakage/cut/loose on fitting
joints
5.
Vacuum pump connector is
loose/open from MMCB
Case 1:
Switch ON the meniscus vacuum
switch.
Case 2:
Contact the head office.
Case 3:
Replace the pump.
Case 4:
Replace the ink/air tub or tighten if
loose.
Case 5:
Tighten the Vacuum Pump Conn-
ector or close from MMCB.