background image

at the back of the heater. They should be located outside the physical footprint of the units to minimize 

heat  build-up  behind  the  heater.  The  installation  must  be  equipped  with  an  all-pole  disconnection 

mechanism  with  a  break  contact  distance  of  at  least  3mm.  The  All-pole  disconnection  mechanism 

must be installed on the height less than 1.8m from the floor. 

  The heater is to be installed so that switches and other controls cannot be touched by a person in the 

bath or shower. 

  If the heater is to be mounted on an incline (eg. Vaulted ceiling), ensure the electrical connection is 

located at that lowest point of the heater.   

  Do not connect the appliance to the mains source until it has been installed in its final location and 

adjusted to the position it will be used in. 

  Do  not  operate  with  the  cord  coiled up as  this  could  cause  a build up of  heat,  which  could  pose  a 

hazard. 

  The use of an extension cord with this appliance is not recommended. 

  Do not allow cord to come in contact with heated surfaces during operation. 

  Do not run cord under carpeting, throw rugs or runners etc. Arrange cord away from areas where it is 

likely to be tripped over. 

  Children and persons with reduced physical, sensory or mental capabilities or lack of experience and 

knowledge are not allowed to use the appliance unless they have been given supervision or instruction 

concerning use of the appliance in a safe way and understand the hazards involved. Children shall not 

play  with  the  appliance.  Cleaning  and  user  maintenance  shall  not  be  made  by  children  without 

supervision. 

  The appliance is only intended for the purpose described in user manual. 

  Do not use appliance or any part of the appliance out of the intended use to avoid risk. 

  The  use  of  attachments  which  are  not  recommended  or  sold  by  the  appliance  manufacturer  may 

cause a risk of injury to persons. 

  CAUTION — some parts of this product can become very hot and cause burns. Particular attention 

has to be given where children and vulnerable people are present. 

  Install and operate the heater in strictly horizontal position on the ceiling or ceiling structural elements. 

At that, thermal resistance of the ceiling coating material should be at least 80 °C.   

  WARNING: This heater is not equipped with a device to control the room temperature. Do not use this 

heater in small rooms when they are occupied by persons not capable of leaving the room on their 

own, unless constant supervision is provided.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for CLHR-20WR

Page 1: ...www colorato net INSTRUCTION MANUAL FOR ELECTRIC INFRARED HEATERS MODEL CLHR 20WR Read carefully this manual before using the appliance and keep it for future reference ...

Page 2: ... Do not use the appliance in particularly duty and explosive areas Do not use the appliance in a building site green house barn or stable where there s flammable dust Do not use the appliance as a sauna heater Warning Do not touch the radiating plate To avoid burns do not touch the appliance surface by hand and other body parts It is also necessary to exclude the possibility of touching the heater...

Page 3: ... is likely to be tripped over Children and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge are not allowed to use the appliance unless they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be ...

Page 4: ...stance of 1 8 m above the ground 0 65m from walls 0 3 m from the ceiling 1 5 m from the combustibles like curtains 1 m from persons or animals 2 2 Heating area The infrared strip heater produces radiant heat which heats objects rather than the air Therefore it is imperative that objects or people to be heated are within the direct radiant footprint of the heater The below diagrams show the approxi...

Page 5: ... the package 5A Nut M8 1 Fixed on NO 5 Bolt M8 60 6 Washer Ø6 2xØ14x1 1 Fixed on No 2A Bolt M6 100 7 Washer Ø8 2xØ16x1 3 2 pcs Fixed on Bolt of No 2B and 1 pc on Bolt of No 5 8 Spring Washer Ø8 2xØ11x1 5 2 Fixed on Bolt of No 2B and No 5 Tools needed Screwdriver spanner These tools need be prepared by the final user Step 2 Take off the screw M6x20 from the heater by screwdriver Attention Please op...

Page 6: ...he main power and press the switch on the pilot lamp will flash and The heater is in stand by mode Press the key ON on the remote control the buzzer responds one sound The pilot will be light The heater will start work in low power mode in first time using or work in the pre set power model Press the KEY LOW set the heater work in 33 of the rated power The buzzer responds one bee sound Press the K...

Page 7: ...he reflector should be cleaned regularly by professionals Do not use any abrasive or caustic cleaning agents Never immerse the appliance in water Danger to life 6 Maintenance Any maintenance or repairs including replacing the bulb element should only be carried out by a qualified electrician 7 Specifications MODEL CLHR 20WR Switch YES Remote controller YES Voltage Frequency 230V 50 Hz Power 2000 I...