![Colorado time systems Pro Pace Clock User Manual Download Page 16](http://html1.mh-extra.com/html/colorado-time-systems/pro-pace-clock/pro-pace-clock_user-manual_2637734016.webp)
touchpad hit occurred after the relay takeoff), the display shows the
difference between the two, preceded by a minus sign. If no valid
RJP input is detected within 2 seconds of a touchpad input, “Err”
will be displayed on the clock.
The clock displays the exchange time for 10 seconds, and then auto-
matically resets itself for the next exchange.
Start Reaction
Mode 6
Equipment required:
Start system or pushbutton, and touchpad for backstroke starts or
RJP for starting block starts. Optional pushbutton for reset.
Set up:
Connect the start system or a pushbutton to the Start System input.
For backstroke starts, connect the touchpad to either Touchpad input.
For starting block starts, connect the RJP to the Relay Platform in-
put. If you would like to use a pushbutton to reset the clock after a
start has been recorded, connect a pushbutton to Reset/Breakout.
Operation:
The clock displays 06, indicating mode 6. The numbers on the dis-
play go blank, leaving the colon and the rightmost decimal lit. The
clock is waiting for a start input. The start input starts the clock and
the display counts up in hundredths of a second for 2 seconds. All
touchpad or RJP inputs detected during this time are recorded, and
the last one recorded is displayed at the end of the 2-second window.
The start reaction time (the difference between the start input and the
swimmer’s departure) is displayed until the clock is reset with a dou-
ble click from the Reset/Breakout input, or a new start input.
If a start input is received and no RJP or touchpad input is detected
within 2 seconds, the clock will display “Err.”
Turn Speed
Mode 7
Equipment required:
Touchpad
Set up:
Connect the touchpad to either of the Touchpad inputs.
Operation:
The clock displays 07, indicating mode 7. The numbers on the dis-
play go blank, leaving the colon and the rightmost decimal lit. The
clock is waiting for a touchpad input (typically hand touch). All
touchpad releases detected during the next 3 seconds are recorded.
The last one recorded (departure) is displayed at the end of the 3-sec-
Training Modes