ting on the mode switch, as described in the Water Polo chapter, be-
ginning on page 7.

Legs

The pace clock includes legs. If you would like to use the legs, attach
them with the hardware included to the threaded mounting holes in
the bottom of the clock.

Side panel

Data cable
connections

On the right end panel, there are four data cable connectors and a
power receptacle. The upper two data cable connections are round,
4-pin connectors for RS-485; the lower two are quarter-inch phono
connectors for RS-232.

AC Power
connection

The power receptacle accepts a standard power cord for 110 VAC. If
220 VAC is required, the power supply can be modified at the fac-
tory. Modified units are labeled accordingly.

Introduction

4

Summary of Contents for Pro Pace Clock

Page 1: ...User Guide Pro Pace Clock and Shot Clock F891 Rev 1106...

Page 2: ...veland CO 80537 USA Sales 1 800 279 0111 or 1 970 667 1000 Service 1 800 287 0653 x256 or 1 970 667 1000 x256 FAX 970 667 1032 Web www coloradotime com Email customerservice coloradotime com Part Numb...

Page 3: ...5 Without Timer or Controller 5 With Timer or Controller 5 3 Water Polo Operation Physical Setup 7 Displaying Information 7 Shot time 7 Game time 8 Time out time 8 Team scores 8 Time of day 8 4 Traini...

Page 4: ...al Setup 19 Swimming 20 Lane Times 20 Event Heat 20 Training Pace Clock 20 Lane Times 20 Diving 20 Dive Number and Position 20 Current Round Current Diver 21 Synchronized Swimming 21 Award 21 All Spor...

Page 5: ...s the training modes in cluding what the mode does and which other devices are needed for the mode Displaying Other Information Chapter 5 beginning on page 19 describes using a Pro Pace Clock Shot Clo...

Page 6: ...e on the left side of the front panel Scoreboard Training When the switch is set to scoreboard and the clock is connected to a timer or controller through the quarter inch phono plug RS 232 or the rou...

Page 7: ...chpad input from both ends of the pool The touchpad inputs are connected to the same in ternal signal so it makes no difference which one is used To take input from touchpads at both ends of the pool...

Page 8: ...panel Data cable connections On the right end panel there are four data cable connectors and a power receptacle The upper two data cable connections are round 4 pin connectors for RS 485 the lower two...

Page 9: ...pace clock s to Scoreboard and Mode 1 Connect the pace clocks with data cables using the round 4 pin RS 485 connectors All connected pace clocks will display the same information Turn the pace clocks...

Page 10: ...Pace Clock Operation 6...

Page 11: ...play the information based on its mode setting a series of connected clocks will display different information from one another if they are set to different mode settings Displaying Information Clocks...

Page 12: ...e switch to 5 The CTS timer will automatically start and stop the time out clock Team scores To display team scores the CTS timer must be set to display Score board Channel 5 team scores on Module 0D...

Page 13: ...13 10 11 12 13 14 Single Lane Timer 1 2 3 4 or multiple laps 14 15 Mid race Timer 16 16 Test Mode 17 Lap counter Mode 1 Equipment required Touchpad required start system or pushbutton can be used to r...

Page 14: ...ng the time as minutes and seconds After displaying 59 59 the display will roll over to 00 00 A start input or a double click from the reset input will reset and start the clock Pace clock with Cumula...

Page 15: ...e of the touchpad hit lap split in seconds and hundredths SS HH The running time is reset to 0 at the touchpad hit and continues running internally Following the lap split display the clock will resum...

Page 16: ...play go blank leaving the colon and the rightmost decimal lit The clock is waiting for a start input The start input starts the clock and the display counts up in hundredths of a second for 2 seconds...

Page 17: ...out input or until a new start input starts the clock from zero Start Reaction and Breakout Time Mode 9 Equipment required Start system breakout timer or pushbutton and touchpad or relay platform Set...

Page 18: ...ct a pushbutton to the Re set Breakout input Operation The clock displays 10 11 12 13 or 14 indicating the mode These modes are the same except for the number of touchpad inputs ex pected In all five...

Page 19: ...ts running time continues in ternally while the display shows the cumulative split The display then resumes running time after displaying each cumulative split un til the third touchpad input This fin...

Page 20: ...one end only the timing will include one lap and three turns 2 With a touchpad at each end the timing will include one length and two turns Equipment required Start system or pushbutton and touchpad s...

Page 21: ...the turn at the other end The clock displays the mid race time until the clock is reset with a double click from the Reset Breakout input or a start input Test Mode Mode 16 Equipment required Depends...

Page 22: ...Training Modes 18...

Page 23: ...the Mode dial on the clock as listed in the chart above and the sport the timer is running Set the Scoreboard Training switch to Scoreboard Connect one pace clock to the timer at the timer s scoreboar...

Page 24: ...ne Times Modes 1 10 Connect the clock s to a CTS timer running Pace Clock software or to a Pace Clock Controller When a clock is switched to one of the modes 1 through 10 it will briefly display the m...

Page 25: ...know when they will be diving again Synchronized Swimming Award Mode 15 Connect the clock s to a CTS timer running Synchronized Swim ming software When a clock is switched to mode 15 it will briefly d...

Page 26: ...ing Scoreboard Displays Mode Switch Setting Display Sport Firmware 2 0 and above Firmware 1 x Game Clock Water Polo 1 2 Shot Time Water Polo 3 4 Time Out Clock Water Polo 5 6 Team Scores Water Polo 12...

Page 27: ......

Page 28: ...0111 or 1 970 667 1000 Service 1 800 287 0653 x256 or 1 970 667 1000 FAX 970 667 1032 Web www coloradotime com Email customerservice coloradotime com Colorado Time Systems 1551 East 11th Street Lovela...

Reviews: