Data Enabler Pro Product Guide
13
3. Locate the luminaire cable 4-wire PC terminal block
connector inside the Data Enabler Pro housing.
4. Securely install line, neutral, ground, and data in the
terminal block:
• Insert a small flathead screwdriver in the slot above a
wire entry hole.
• Firmly insert the correct wire in the wire entry hole.
• Remove the screwdriver.
Luminaire Cable Connection for iColor Accent MX
Powercore gen2
Data Enabler Pro includes a separate 4-wire IDC
terminal block connector for Ethernet data output to
iColor Accent MX Powercore gen2 luminaires, which
directly accept Ethernet input. Leader cables for eW
and iColor Accent Powercore bundle data and power
wires within the same wire jacket.
1. Run iColor Accent MX Powercore gen2 leader cable
through a cable connector installed on the output
side of the Data Enabler Pro housing (the side with
two openings).
2. Strip off a sufficient length of the cable jacket to
connect the data wires to the IDC terminal block on
the data board and the power wires to the luminaire
cable PC terminal block on the power board.
2. Strip 15 mm (0.6 in) of insulation from the power
wires. If using stranded wire, twist each wire tight to
secure the wire threads.
3. Connect the data wires to the IDC terminal block:
• Using your fingers or a small tool, lift the four punch-
down connectors.
• From right to left, following the wire codes printed
on the data board, insert the Orange/White, Orange,
Blue/White, and Blue wires into the wire entry holes
on the front of the connector.
• Push down each punch-down connector until they
snap firmly in place.
4. Securely install line, neutral, and ground in the
luminaire cable 4-wire terminal block:
• Insert a standard flathead screwdriver in the slot
above a wire entry hole.
• Firmly insert the correct wire in the wire entry hole.
(Leave the data position empty.)
• Remove the screwdriver.
Secure Cover
Once you have finished connecting all data and power
inputs and outputs, secure the Data Enabler Pro cover.
1. Seat the cover on the Data Enabler Pro housing.
2. Using the included 3 mm hex wrench, tighten the
housing cover’s six captured screws.
3. Torque each screw to approximately 1.8 Nm (16 in-lb).
L N
L N
DMX
DMX
Luminaire
output
UL/cUL
UL/cUL
L
N
CE/PSE
CE/PSE
UL/cUL
CE/CQC
L
N
UL/cUL
CE/PSE
L
N
L
N
L N
L N
L N
L N
CE/PSE
CQC
L N
UL/cUL
CE/CQC
PSE
L N
L N
UL/cUL
CE/PSE
L N
L N
L N
CE/PSE
L N
CE/CCC
L N
CE/Japan
L N
CE
L N
CE/PSE
L N
CE/PSE
CCC
L N
UL/cUL
UL/cUL
L
N
CE/PSE
CE/PSE
UL/cUL
CE/CQC
L
N
UL/cUL
CE/PSE
L
N
L
N
L N
L N
L N
L N
CE/PSE
CQC
L N
UL/cUL
CE/CQC
PSE
L N
L N
UL/cUL
CE/PSE
L N
L N
L N
CE/PSE
L N
CE/CCC
L N
CE/Japan
L N
CE
L N
CE/PSE
L N
CE/PSE
CCC
L N
L N
L N
15 mm
(0.6 in)
L N
L N
DMX
DMX
iColor Accent MX
Powercore gen2
output