13 

7.

 

Errors and Troubleshooting 

The troubleshooting tables in this Chapter will help you to determine whether you can troubleshoot yourself or whether you need to call 

customer service. 

 

DANGER 

Danger of death by dangerous voltage 

Please note that all maintenance and servicing jobs must be left strictly to authorized and suitably 

trained expert staff. This applies in particular to those jobs printed on a gray background which 

have to be performed with the housing open. 

 

 

7.1

 

Possible errors messages 

Fault 

Description 

Machine condition 

Solutions 

E010 

Door open 

 

Door open 

 

Close door  

 

 

Door closed 

 

Check the door lock 

 

Check the power cord / plug to the door lock. 

E020 

EMERGENCY STOP 

activated 

 

EMERGENCY STOP button pushed 

 

Release the EMERGENCY STOP 

 

 

EMERGENCY STOP button not 

pushed 

 

Check the switch of the EMERGENCY STOP button 

 

Check the power cord / plug to the EMERGENCY STOP 

button. 

E050 

Defective container 

 

Container is defect 

 

Container is unstable 

 

Check  clamping pressure, if necessary adjust 

E070 

Mixing Unit locked 

 

Latching pin blocked 

 

The latching pin is blocked – clean and lubricate, 

replace if necessary 

 

 

Latching pin released 

 

Check the lead/connector to the switch of the mixing 

unit lock. 

 

The switch of the mixing unit lock is defective.

 

E080 

Mixing Unit unlocked 

 

Latching pin blocked 

 

The mixing unit is not 12 at o'clock position 

 

Check the lead/connector to the switch of the latching 

pin 

 

The switch of the mixing unit lock is defective 

 

 

Latching pin released 

 

Check the lead/connector to the switch of the mixing 

unit lock. 

 

The switch of the mixing unit lock is defective

 

E120 

Mixing speed too low 

 

The mixing unit rotates

 

 

Check the lead/connector to the "position" 

 

proximity switch 

 

The "position" proximity switch is defective

 

 

 

The mixing unit does not rotate

 

 

Check frequency converter 

 

Check the door safety switch 

 

Check the main motor

 

E130 

Mixing speed too high 

 

The mixing unit rotates too fast 

 

Decrease the motor speed

 

E150 

Error clamp motor 

 

The mixing container is not 

clamped 

 

Check the clamp motor 

 

Check the lines to the clamp motor 

 

Check the control 

 

 

 

Summary of Contents for VISCO 550

Page 1: ...Version 1 1 17 Instructions Biaxial Mixer VISCO 550 Keep this manual within immediate reach of the machine Translation of the original instructions en Englisch...

Page 2: ...VISCO 550 Collomix GmbH 2 Version 1 1 17...

Page 3: ...ransport rollers 10 5 4 Mains connection 10 5 5 Trial run 10 6 Operation 11 6 1 Switching on the machine 11 6 2 Load a container 11 6 3 Starting the mixing cycle 12 6 4 Ending the mixing cycle 12 6 5...

Page 4: ...1 17 1 Layout Drawings 1 1 Machine components Machine components 1 Machine legs 5 Manual door release 2 Sliding door 8 Control panel CSE 3 Main switch and DC fuse 7 Lower clamping plate 4 Emergency S...

Page 5: ...N the mixing unit STOP stop mixing cycle prematurely ACKNOWLEDGE messages Button I Mixing cycle I Factory settings 4 00 Minute Button II Mixing cycle II Factory settings 6 00 Minute Button III Mixing...

Page 6: ...e corresponding precautionary measures WARNING This signal word is used if death or severe physical injuries may result from not paying attention to the corresponding precautionary measures ATTENTION...

Page 7: ...ating Instructions before working with the machine Keep the Operating Instructions within immediate reach of the machine Please hand the Operating Instructions to any subsequent owners 3 1 General Saf...

Page 8: ...bvious malfunctions Repair cleaning and maintenance work without disconnecting the system from power WARNING Danger of injury through improper modifications Hazards exist through unauthorized modifica...

Page 9: ...re taken there may be obvious residual risks Adhering to the safety instructions the designated use and the operating instructions as a whole can reduce residual risks 4 Equipment Description The biax...

Page 10: ...e legs 1 5 3 Transport rollers The mixer is equipped with two transport rollers on the bottom of the housing These transport rollers can be made to protrude out of the mixing compartment by turning a...

Page 11: ...mixing vessels To place the container proceed as follows Unlock and open the door by pushing the DOOR button Unlock the lower clamping table 7 by pressing the locking lever 8 to the left and pulling i...

Page 12: ...done working switch the machine off at the mains 3 6 6 EMERGENCY STOP switch In dangerous situations the machine can be turned off with the EMERGENCY STOP switch After the EMERGENCY STOP button is pr...

Page 13: ...ntainer is defect Container is unstable Check clamping pressure if necessary adjust E070 Mixing Unit locked Latching pin blocked The latching pin is blocked clean and lubricate replace if necessary La...

Page 14: ...upon interruption of the power supply during the mixing process AUTO With the container clamped or the mixing unit not loaded the mixing unit can be automatically positioned and fixed with the help o...

Page 15: ...he machine from the mains by pulling out the mains plug Never use the manually door unlocking device whilst the mixing unit is turning 7 4 Fuses on the device 7 4 1 Device fuse If line voltage is avai...

Page 16: ...h dry run ball bearings If you clean the machine with a high pressure washer the lubricant is washed out from the ball bearings and they run try Never clean the machine with a high pressure washer or...

Page 17: ...safety equipment and electrical equipment is to verify and document after the repair Only use original spare parts Do not modify or change safety related parts Any additional components added may not...

Page 18: ...nt any damages through outside impacts during storage If necessary use cardboard and other packaging material Secure the machine against unintentional tilting and instability 9 2 Disposal The transpor...

Page 19: ...fuse 10 AT Line fuse 16 A C RCD Typ B Speed of mixing unit 630 rpm Mixing weight max 12 5 kg Container height 90 300 mm Container diameter max 300 mm Ambient temperature 5 30 C Machine weight 189 kg N...

Page 20: ...VISCO 550 Collomix GmbH 20 Version 1 1 17 10 2 Dimensions...

Page 21: ...rmation from Collomix GmbH Abt Technische Entwicklung Daimlerstr 9 85080 Gaimersheim Deutschland Gaimersheim 2016 06 01 Alexander Essing Managing Director Manufacturer Collomix GmbH Daimlerstr 9 85080...

Page 22: ...VISCO 550 Collomix GmbH 22 Version 1 1 17...

Page 23: ...Collomix GmbH VISCO 550 Version 1 1 17 23...

Page 24: ...VISCO 550 Collomix GmbH 24 Version 1 1 17 Collomix GmbH Daimlerstr 9 D 85080 Gaimersheim Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458 32 98 30 www collomix de...

Reviews: