background image

*

13 HP Honda OHV engine

*

Cast-iron cylinder sleeve

*

Low oil sensor

*

Receptacles on control panel 

*

Voltmeter and hour meter on panel

*

Idle control

*

Automatic voltage regulator (AVR)

*

Battery charger

*

CordKeeper™

*

4.6 gallon metal fuel tank 

*

Spark arrester

*

Portability Kit

A. 120/240 V, 30 Ampere Twistlock Receptacle

A maximum of 30 amps may be drawn from the 120/240 

volt receptacle, provided it is the only receptacle used. 
However, current must be limited to the nameplate rating.  If the
120/240 volt receptacle is used along with the 120 volt
receptacle, the total load drawn must not exceed the nameplate
ratings.

B. Idle Control Switch

Some models are equipped with an idle control switch. 

(See Idle Control).

C. Circuit Breakers

The receptacles are protected by an AC circuit breaker.  If

the generator is overloaded or an external short circuit occurs,
the circuit breaker will trip.  If this occurs, disconnect all
electrical loads and try to determine the cause of the problem
before attempting to use the generator again. If overloading
causes the circuit breaker to trip, reduce the load. 

NOTE:

Continuous tripping of the circuit breaker may cause
damage to generator or equipment.  

The circuit breaker may

be reset by pushing the button of the breaker.

D. Hour Meter

An hour meter is provided to keep track of run time of the

unit.  This may be used to track maintenance schedules.

E. Voltmeter

Provides visual indication of generator output voltage from 

0-300 volts.

F.

120 Volt GFCI Receptacle

Ground Fault Circuit Interrupter duplex receptacle is rated

so that a total of 20 amps may be drawn regardless of whether
both halves or just one receptacle is used.  This receptacle may
be used along with other receptacles provided the generator is
not overloaded and total power drawn is kept within nameplate
ratings.

Ground Fault Circuit Interrupter

(Conforms to U.L 943, Class A and NEC requirements)
This device protects you against hazardous electrical shock
that may be caused if your body becomes a path through which
electricity travels to reach ground.  This could happen when
you touch an appliance or cord that is “ live “ through faulty
mechanism, damp or worn insulation, etc.

G. 120 V, 30 Ampere Twistlock Receptacle

You may draw a maximum of 30 amps or 3600 watts from

this receptacle.  If other receptacles are used at the same time,
total power used must be kept within nameplate ratings.

H. CordKeeper™

The CordKeeper™ is a unique

feature used to prevent plugs from
being pulled out of the 120-volt
receptacles.

I.

Battery Charger
NOT RECOMMENDED FOR USE WITH GEL PACK,

SEALED OR SMALL (MOTORCYCLE) BATTERIES.

These generators contain an additional circuit used for

battery charging purposes.  A double binding post is provided
on the control panel.  The battery charger on this generator is
referred to as an unregulated taper charger - the most widely
used in the market today.  The amount of current flowing will
depend on the charging voltage and battery's state of charge.
As the battery becomes more fully charged, the output current
to the battery decreases and nearly becomes constant.  Taper
chargers are intended to be used with the provision that they
will be disconnected from the battery after a maximum time on
charge.  Normally a period of 30 to 120 minutes is sufficient to
recharge a weak battery.  The charge level of the battery
should be checked periodically.  

CAUTION:  This battery charging system is 
intended to recharge weak batteries, not to 
"boost start" vehicles.  Do not overcharge 
battery or leave battery unattended.

Note: 

When  the  battery  charger  circuit  is  in  use,  the  AC

capacity  is  reduced  by  180  watts.    Make  sure  the  combined
load is within the rated limits.

Before charging a storage battery, check the electrolyte

fluid level in all the cells.  Add distilled water to each cell, if
necessary, to bring the level back up to the manufacturer's
required level.

WARNING:  Storage batteries give off 

EXPLOSIVE hydrogen gas while charging. 
Do not allow smoking, open flames,sparks,
or spark producing equipment in the area 
while charging.

2

English

CONTROL PANEL

MAJOR GENERATOR FEATURES

Summary of Contents for Powermate PM0496504

Page 1: ...ovided prior to operation IMPORTANT Prière de vous assurer que les personnes destinées à utiliser cet appareil ont pris soin d en lire et d en comprendre le mode d emploi ou les directives avant de le mettre en marche IMPORTANTE Asegúrese que las personas que utilizarán este equipo lean y entiendan completamente estas instrucciones y cualquier instrucción adicional proporcionada antes del funciona...

Page 2: ...l shock that may be caused if your body becomes a path through which electricity travels to reach ground This could happen when you touch an appliance or cord that is live through faulty mechanism damp or worn insulation etc G 120 V 30 Ampere Twistlock Receptacle You may draw a maximum of 30 amps or 3600 watts from this receptacle If other receptacles are used at the same time total power used mus...

Page 3: ...esigned to extend engine life and improve fuel usage by slowing the engine down to approximately 2000 RPM in a No Load condition The noise is also greatly reduced during this condition When power is required from the generator an electronic control module automatically senses current flow in the electrical outlet and allows the engine to return to full speed or standard operating condition Likewis...

Page 4: ...ted States or Canada Any other expense including consequential damages incidental damages or incidental expenses including damage to property Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you IMPLIED WARRANTIES Any implied warranties including the Implied Warranties of Merchantability and Fitness Fo...

Page 5: ... circuit en cas de fuite à la terre conforme à U L 943 Catégorie A et ixigences NEC Cet appareil vous protège contre les dangers de chocs électriques qui peuvent ítre causés si votre corps devient un conduit pour l électricité se rendant à la terre Ceci peut se produire si vous touchez u appareil ou un cordon qui est sous tension suite à un mécanisme défectueux un isolant usé ou humide etc G Prise...

Page 6: ...le du moteur et en améliorer la consommation de carburant en réduisant le régime à environ 2000 tours mn en condition sans charge Ceci assure également une forte réduction du bruit Lorsque la production d électricité doit reprendre un module de commande électronique sent le débit de courant dans la prise de courant et permet au moteur de retourner à son plein régime ou aux conditions de fonctionne...

Page 7: ... Tous autres frais y compris ceux dûs à des dommages indirects ou accidentels ni les dépenses imprévues y compris les dommages matériels Certaines provinces ne permettent pas l exclusion ou la limitation des dommages indirects ou accidentels et les limitations ou exclusions ci dessus peuvent ne pas s appliquer à votre cas GARANTIES IMPLICITES Toutes garanties implicites y compris les Garanties imp...

Page 8: ... sacudida eléctrica peligrosa que puede causarse cuando su cuerpo se convierte en una senda por la cual la electricidad viaja para alcanzar la tierra Esto podría suceder cuando usted toca un aparato o la cuerda que es vive por mecanismo defectuoso aislamiento húmedo o llevado etc G Receptáculo de cierre giratorio de 120 voltios Puede extraerse un máximo de 30 amp o 3600 vatios desde este receptácu...

Page 9: ...e reduce mucho en estas condiciones Cuando se requiere potencia desde el generador un módulo de control electrónico automático detecta el flujo de corriente en el tomacorriente eléctrico y permite que el motor vuelva a plena velocidad o a condiciones de funcionamiento estándar Del mismo modo cuando se retira la carga el generador automáticamente regresará a la condición de marcha en vacío después ...

Page 10: ...garantías de su fabricante Las ventas fuera de los Estados Unidos Canadá Cualquier otro gasto incluyendo daños emergentes daños o gastos incidentales incluyendo daños a la propiedad Algunos estados no permiten la exclusión o limitación de daños incidentales o emergentes de modo que la limitación o exclusión anterior podría no ser aplicable en su caso particular GARANTIAS IMPLICITAS Cualquier garan...

Page 11: ...11 PARTS DRAWING SCHEMA DES PIÈCES DIAGRAMA DE PIEZAS PM0496504 ...

Page 12: ...39 Bracket stator Sectionneur stator Conjunto de soporte 1 22 0049279 Bolt wz 5 16 18 x 1 2 Boulon Perno 3 23 0048736 Nut nyloc 5 16 18 Écrous nyloc 5 16 18 Tuerca nyloc 5 16 18 5 24 0061393 Nut whz 8mm Écrous Tuerca 2 25 Note B Washer flat 5 16 Rondelles plates 5 16 Arandela plana 5 16 5 26 Note B Bolt 5 16 18 x 1 1 2 Boulon Perno 2 27 0000901 01 Bolt whz 5 16 24 x 5 8 Boulon Perno 2 28 0049224 A...

Page 13: ...marque C Pour commander un réservoir de rechange contacter Centre de service Coleman Powermate le plus proche DANGER Pour éviter toute blessure personnelle ou dommage à l équipement l installation et tout entretien devralent être effectués par un électricien qualifié ou un préposé au service autorisé En aucun cas une personne non qualifiée ne devrait essayer de faire le raccord au circuit principa...

Page 14: ...NOTES REMARQUES NOTAS 14 ...

Page 15: ...NOTES REMARQUES NOTAS 15 ...

Page 16: ... of Coleman Powermate Inc 2004 Coleman Powermate Inc Tous droits réservés sont des marques déposées de The Coleman Company Inc utilisées sous licence Powermate est une marque déposée de Coleman Powermate Inc 2004 Coleman Powermate Inc Reservados todos los derechos son marcas comerciales registradas de The Coleman Company Inc utilizadas bajo licencia Powermate es una marca comercial registrada de C...

Reviews: