background image

TECHNICAL GUIDE

Echelon 

SPLIT-SYSTEM HEAT PUMPS

18 SEER – R-410A 

MODELS:

HC8B024 THRU 060
(2 THRU 5 NOMINAL TONS)

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com

Additional rating information can be found at 
www.ari.org/aridirectory

ISO 9001

Certified Quality

Management System

LISTED

345095-CTG-B-0907

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

The HC8BSeries unit is the outdoor part of a versatile heat pump
system. It is designed to be custom matched with one of our
complete line of evaporator sections, each designed to serve a
specific function. Matching air handlers are available for upflow,
downflow, and horizontal left or right application to provide a
complete system. Electric heaters are available if required. Add-
on coils are available for use with upflow, downflow, or horizontal
furnaces. Field installed accessories are available as needed.

WARRANTY

5-year limited parts warranty.
10-year limited compressor warranty.
Premium System Warranty - Limited lifetime compressor and 10-
year parts when matched with an approved Coleman Echelon
furnace or UPG air handler and coil.

FEATURES

Superior Coil Protection – 

A  PVC coated steel coil guard com-

pletely protects coil from debris and other large damaging material
while a polymer mesh further protects the coil against smaller par-
ticles.

Isolated Compressor Compartment –

 A molded composite

bulkhead isolates the compressor from the rest of the unit reduc-
ing sound and vibration.

Protected Compressors – 

Each compressor is protected against

high and low pressure as well as excessive temperature. This is
accomplished by by the simultaneous operation of a high pres-
sure relief valve and temperature sensors which protect the com-
pressor if undesirable conditions occur.

Environmentally Friendly Refrigerant – 

Next generation refrig-

erant R-410A delivers environmentally friendly performance, with
zero ozone depletion.

Durable Finish – 

Automotive quality finish provides the ultimate

protection from harmful U.V. rays as well as rust creep ensuring
long-lasting high quality appearance. A powder-paint topcoat is
applied over a baked-on primer, using a galvanized, zinc coated
steel base material. The result is a finish that has been proven in
testing to provide 33% greater durability than conventional pow-
der-coat finishes.

Lower Installed Cost – 

Designed to provide enhanced installabil-

ity by featuring a slide-down control compartment allowing easy
access to control components along with angled service valves to
reduce overall installation time and cost.

Low Operating Sound Levels – 

A fan design boasting technol-

ogy adapted from aeronautic and defense engineering provides
for whisper quiet operation by allowing airflow to flow smoothly
and efficiently across the fan tips. 

Filter-Drier 

– A factory installed, solid core liquid line filter-drier fil-

ters harmful debris and moisture from the system. 

Easy Service Access – 

A full end, full service, access panel with

handle makes for easy entry to internal components.

Long Lasting Operation – 

Strong and durable composite base

pan provides added strength while resisting rust and corrosion as
well as reducing sound and vibration.

WhisperDrive

TM

 system -

 The swept-wing fan, composite base

pan, isolated compressor compartment and two-stage compres-
sor are engineered as a system to reduce overall sound to a mere
whisper.

Complete System Control – 

All models utilize the exclusive

microprocessor based, on-demand, defrost control system. This
system provides optimal comfort, efficiency, and constant montor-
ing of the entire system for reliable operation. defrost cycles occur
only when necessary. an adjustable balance point insures supple-
mental heat is brought on only when required to meet the space
load, for optimum efficiency and reliability.

In the event improper operating conditions occur (high tempera-
ture and/or high pressure), the unit will automatically shut down to
protect the refrigeration system, and switch to back-up heat. On-
board diagnostic LED’s guide the technician to the source of the
problem, and an output signal from the control to the thermostat
will alert the homeowner. The control also features non-volatile
memory, which preserves trouble codes in the event of power
loss. An anti-short cycle timer extends the life of the compressor
by preventing short-cycling.

Certified in accordance with the Unitary Small Equipment certification
program, which is based on ARI Standard 210/240.

Summary of Contents for HC8B024F1

Page 1: ...r paint topcoat is applied over a baked on primer using a galvanized zinc coated steel base material The result is a finish that has been proven in testing to provide 33 greater durability than conven...

Page 2: ...Coil Face Area Sq Ft 23 58 23 58 23 58 23 58 Rows Deep 2 2 2 2 Fins Inch 16 16 14 14 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 Vapor Line Set OD Field Installed 3 4 3 4 7 8 7 8 Unit Charge Lb...

Page 3: ...410A Charge TXV Size for Various Matched Systems Outdoor Unit HC8B024F1 HC8B036F1 HC8B048F1 HC8B060F1 Approved System Thermal Expansion Valve1 1TVM903 1TVM906 1TVM906 1TMV906 Factory R 410A Charge lb...

Page 4: ...7 0 36 6 12 50 HC8B060F1 MV20D 24 FC MC60D 1 1175 39 5 27 6 14 75 12 20 2 1820 57 0 42 0 11 35 MV20D 24 FC MC62D 1 1175 41 0 29 8 15 50 12 80 2 1820 57 0 43 0 11 80 18 SEER HP WITH AV SV VARIABLE SPEE...

Page 5: ...FC MC PC48C 21 1 770 25 0 18 4 17 5O 14 60 2 1175 35 4 26 6 13 45 FC9 C V C20 FC MC PC48C 21 1 790 25 0 18 6 17 2O 14 30 2 1195 35 4 26 6 15 00 FC9 C V D20 FC MC PC48D 24 1 775 25 0 18 6 17 3O 14 40...

Page 6: ...13 30 2 1560 46 5 35 8 12 00 F L C8 C V C20 FC MC62D 21 1 1030 33 6 25 4 16 7O 13 60 2 1610 46 5 36 0 11 85 FC9 C V C20 FC MC62D 21 1 1010 33 2 25 2 16 4O 13 35 2 1580 46 0 36 0 11 80 FC9 C V D20 FC...

Page 7: ...1 1045 35 8 3 8 2 1570 48 0 32 0 9 8 4 0 2 1045 38 0 25 0 9 5 3 2 HC8B060F1 MV20D FC MC60D 24 1 1175 43 0 3 4 2 1820 58 0 39 5 9 3 3 8 2 1175 46 5 27 4 9 3 0 MV20D FC MC62D 24 1 1175 43 0 3 4 2 1820...

Page 8: ...26 6 4 00 2 1195 36 0 26 6 9 55 4 20 2 790 36 0 24 4 9 2 3 20 F L C8 C V C16 FC MC PC48C 21 1 640 26 0 3 80 2 1200 36 0 26 4 9 55 4 20 2 640 36 0 24 4 9 2 3 00 F L C8 C V C20 FC MC PC48C 21 1 780 26...

Page 9: ...3 3 80 2 880 38 0 25 4 9 3 00 F L C8 C V C20 FC MC PC48C 21 1 1030 36 0 3 80 2 1610 48 0 32 8 9 3 3 80 2 1030 38 0 25 4 9 3 00 FC9 C V C16 FC MC PC48C 21 1 1090 36 0 3 80 2 1600 48 0 33 0 9 3 3 80 2 1...

Page 10: ...C V C20 FC PC60C 21 1 1075 43 0 3 40 2 1650 58 0 39 5 9 3 3 80 2 1075 46 5 27 2 9 3 00 FC9 C V D20 FC MC PC60D 24 1 1020 43 0 3 40 2 1620 58 0 39 0 9 3 3 80 2 1020 46 0 27 2 9 3 00 F L C8 C V C20 FC...

Page 11: ...r Heat Pump Risers 526 35389 000 526 35390 000 526 35391 000 3 6 or 12 risers mount easily in composite base pan recesses ensuring the unit stays clear of snow and ice build up in harsh winter weather...

Page 12: ...1 7 18 1 18 0 18 0 20 0 21 7 18 1 18 0 18 0 20 0 21 7 S C 18 1 17 7 15 0 15 0 12 1 18 1 17 7 15 0 15 0 12 1 18 1 17 7 15 0 15 0 12 1 K W 1 0 1 0 1 1 1 1 1 1 1 0 1 0 1 1 1 1 1 1 1 0 1 0 1 1 1 1 1 1 95...

Page 13: ...28 3 24 0 24 5 24 4 26 7 28 9 24 9 25 0 24 9 27 2 29 5 S C 23 1 22 0 18 5 18 4 15 0 24 0 23 3 19 6 19 5 15 6 24 9 24 6 20 7 20 6 16 2 K W 1 5 1 5 1 5 1 5 1 6 1 5 1 5 1 5 1 5 1 6 1 5 1 5 1 5 1 6 1 6 95...

Page 14: ...6 21 1 23 8 26 8 22 3 21 9 21 3 24 1 27 0 S C 21 4 21 3 17 9 18 0 14 2 21 8 21 6 18 4 18 6 14 5 22 3 21 9 18 9 19 2 14 9 K W 1 8 1 8 1 8 1 8 1 9 1 8 1 8 1 8 1 8 1 9 1 8 1 8 1 8 1 8 1 9 115 T C 19 8 19...

Page 15: ...32 9 32 3 35 7 39 1 33 8 33 5 32 7 36 0 39 5 S C 32 2 31 6 26 9 26 7 20 9 33 0 32 5 28 0 27 8 21 5 33 8 33 5 29 1 28 8 22 2 K W 2 7 2 7 2 7 2 8 2 8 2 8 2 8 2 7 2 8 2 8 2 8 2 8 2 8 2 8 2 8 115 T C 30 3...

Page 16: ...31 5 31 4 34 9 38 4 S C 30 2 29 5 24 5 24 5 19 4 30 7 30 3 25 1 25 1 19 8 31 2 31 2 25 7 25 7 20 2 K W 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 105 T C 28 3 28 7 28 2 31 6 34 9 28 7...

Page 17: ...43 8 43 7 47 7 52 2 S C 42 6 41 7 34 5 34 3 26 8 43 4 42 8 35 6 35 3 27 4 44 2 43 8 36 6 36 3 28 0 K W 3 3 3 3 3 3 3 4 3 5 3 3 3 3 3 3 3 4 3 5 3 3 3 3 3 3 3 4 3 5 105 T C 40 1 40 4 40 0 43 6 47 5 40...

Page 18: ...8 38 5 36 6 30 4 30 4 24 3 39 2 37 5 31 1 31 0 24 7 K W 2 7 2 7 2 7 2 7 2 7 2 7 2 7 2 7 2 7 2 7 2 7 2 7 2 7 2 7 2 7 95 T C 36 4 37 9 37 8 42 2 46 7 37 0 38 4 38 3 42 6 47 2 37 6 38 9 38 8 43 0 47 6 S...

Page 19: ...9 54 4 52 4 43 7 43 3 34 5 55 3 53 9 44 9 44 4 35 1 K W 3 8 3 8 3 8 4 0 4 1 3 8 3 8 3 9 4 0 4 1 3 8 3 9 3 9 4 0 4 1 95 T C 51 5 52 6 52 6 57 7 63 1 52 4 53 1 53 2 58 2 63 5 53 3 53 6 53 7 58 7 63 9 S...

Page 20: ...1 19 4 1 4 4 2 80 18 8 1 6 3 6 18 9 1 5 3 6 19 0 1 5 3 7 40 60 17 1 1 2 4 1 17 1 1 2 4 2 17 1 1 2 4 3 70 16 9 1 4 3 7 16 9 1 3 3 7 17 0 1 3 3 8 80 16 7 1 5 3 3 16 7 1 5 3 3 16 8 1 4 3 4 30 60 13 9 1...

Page 21: ...6 8 1 7 4 7 80 25 9 1 9 3 9 26 1 1 9 4 1 26 3 1 8 4 2 40 60 24 4 1 6 4 5 24 5 1 5 4 7 24 6 1 5 4 9 70 23 9 1 7 4 1 24 1 1 7 4 2 24 3 1 6 4 4 80 23 5 1 9 3 7 23 7 1 8 3 8 23 9 1 8 3 9 30 60 20 7 1 5 4...

Page 22: ...1 3 1 4 6 7 1 3 1 5 70 6 5 1 5 1 2 7 0 1 5 1 4 7 5 1 5 1 5 80 7 6 1 7 1 3 8 0 1 7 1 4 8 3 1 7 1 5 NOTE ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH 1000 CFM Air Handler Coil MBH KW COP AV36 1 0...

Page 23: ...19 4 1 9 3 0 19 5 1 9 3 1 70 19 3 2 1 2 6 19 3 2 1 2 7 19 3 2 1 2 7 80 19 2 2 4 2 4 19 2 2 3 2 4 19 2 2 3 2 4 NOTE ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH 1000 CFM Air Handler Coil MBH KW...

Page 24: ...1 2 5 2 8 80 23 9 2 8 2 5 23 8 2 8 2 5 23 7 2 7 2 5 17 60 18 1 2 2 2 4 18 2 2 2 2 5 18 2 2 1 2 5 70 18 0 2 5 2 1 18 0 2 4 2 2 18 1 2 4 2 2 80 17 8 2 7 1 9 17 9 2 7 2 0 18 0 2 6 2 0 10 60 15 0 2 2 2 0...

Page 25: ...7 7 3 0 3 6 80 37 0 3 4 3 2 37 1 3 3 3 3 37 2 3 3 3 3 17 60 30 4 2 7 3 3 30 5 2 6 3 4 30 6 2 6 3 5 70 30 1 2 9 3 0 30 2 2 9 3 1 30 3 2 9 3 1 80 29 8 3 2 2 8 29 9 3 1 2 8 30 0 3 1 2 8 10 60 26 7 2 6 3...

Page 26: ...9 3 2 3 4 36 8 3 2 3 4 70 36 9 3 6 3 0 36 9 3 6 3 0 36 9 3 5 3 1 80 36 9 4 0 2 7 36 9 4 0 2 7 36 9 3 9 2 8 30 60 31 3 3 2 2 9 31 3 3 1 2 9 31 3 3 1 3 0 70 31 3 3 5 2 6 31 4 3 5 2 6 31 4 3 5 2 7 80 31...

Page 27: ...3 8 3 8 4 2 53 9 3 7 4 3 70 53 1 4 2 3 7 53 2 4 1 3 8 53 3 4 1 3 8 80 52 4 4 6 3 4 52 6 4 5 3 4 52 8 4 4 3 5 30 60 45 9 3 6 3 7 46 1 3 6 3 8 46 3 3 5 3 8 70 45 4 4 0 3 3 45 6 3 9 3 4 45 7 3 9 3 5 80 4...

Page 28: ...o change without notice Printed in U S A 345095 CTG B 0907 Copyright by Unitary Products Group 2007 All rights reserved Supersedes 345095 CTG A 0907 Unitary 5005 Norman Products York OK Group Drive 73...