8

In Case of Contamination

 

WARNING: THE FOLLOWING PROCEDURE IS INTENDED AS A GUIDE. SHOULD SPILLAGE OF A

 

TOXIC OR HAZARDOUS FLUID OCCUR, THEN ADDITIONAL SPECIAL PRECAUTIONS MAY

 

BE NECESSARY.

If the equipment has been exposed to contamination, the Responsible Body is responsible for carrying out
appropriate decontamination. If hazardous material has been spilt on or inside the equipment, decontamination 
should only be undertaken under the control of the Responsible Body with due recognition of possible hazards. 
Before using any cleaning or decontamination method, the Responsible Body should check with the manufacturer 
that the proposed method will not damage the equipment. Prior to further use, the Responsible Body shall check 
the electrical safety of the unit. Only if all safety requirements are met can the unit be used again.

NOTE: 

In the event of this equipment or any part of the unit becoming damaged or requiring service, the item(s) 

should be returned to the manufacturer for repair accompanied by a decontamination certificate. Copies of the 
Certificate are available from the Distributor/Manufacturer.

At the end of its service life, the product must be accompanied by a Decontamination Certificate.

Repairs and Support

Any repairs or replacement of parts MUST be undertaken by suitably qualified personnel. Only spare parts supplied 
or specified by Antylia Scientific or its agents should be used. Fitting of non-approved parts may affect the per-
formance and safety features designed into the instrument. For a comprehensive list of parts required by service 
engineers conducting internal repairs please contact the service department quoting the model and serial number:

Email: [email protected]
Tel: +44 (0)1785 810475

For any other technical enquiries please contact the Technical Support Department at:
Email: [email protected]
Tel: +44 (0)1785 810433

Antylia Scientific Ltd,
Beacon Road,
Stone,
Staffordshire,
ST15 0SA,
United Kingdom
Email: [email protected]
Tel: +44 (0)1785 810475
Web: www.Cole-Parmer.com

Spares and Accessories 

Please contact your local sales specialist or email [email protected] to enquire about available spares.

Please visit www.Cole-Parmer.com for a full list of available accessories.

Summary of Contents for MH8524

Page 1: ...Cole Parmer WD 200 Series Paraffin Wax Dispenser Instruction Manual ET0003 Version 1 1 ...

Page 2: ... following conditions v For indoor use only v Use in a well ventilated area v Ambient temperature range 5 C to 40 C 41 F to 104 F v Altitude to 2000 m 6500 ft v Relative humidity not exceeding 80 temperature 31ºC decreasing to 50 temperature 40ºC v Mains supply fluctuations not exceeding 10 of nominal v Overvoltage category II IEC60364 4 443 v Pollution degree 2 IEC664 v Use with a minimum distanc...

Page 3: ...RDS OR UNSAFE PRACTICES ARE DANGEROUS as they can cause severe personal injury fire or death v DO NOT use combustible substances near hot objects v DO NOT use the equipment in hazardous atmospheres v DO NOT immerse the equipment in water v DO NOT operate or handle any part of the product with wet hands or use on surfaces that may become flooded v NEVER move the product while still connected to the...

Page 4: ...replace the plug with a suitable alternative THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN NOTE Refer to the equipment rating plate to ensure that the plug and fusing are suitable for the voltage and wattage stated The wires in the mains cable are as follows 230V 120V BROWN HOT LIVE BLACK HOT LIVE BLUE NEUTRAL WHITE NEUTRAL GREEN YELLOW EARTH GREEN EARTH The appropriate power...

Page 5: ...tion 1 Ensure that the power cable is pushed fully into the power supply socket of the wax dispenser 2 Connect the mains plug to the electrical supply 3 Pour the desired quantity of wax into the internal tank The tank has a maximum capacity of 7 5L which is large enough to melt 6 0kg of pelletized histology wax 4 Turn ON the wax dispenser 5 Set the desired temperature Users are recommended to set ...

Page 6: ...in as quick a time as possible When set at 65o C the instrument will take roughly 90 minutes to fully melt 5kg of pelletized wax with significant quantities of molten wax available for use after as little as 30 minutes 9 Wax is delivered by pulling the tap lever forward The tap has three positions i Off ii On demand pull dispense iii Continuous flow tap locked open CAUTION Do not operate the tap w...

Page 7: ...d for more thorough cleaning using solvents If removing the filter it is recommended that protective gloves are worn NOTE DO NOT use scouring pads de scaling agents or solvents to clean any parts of this equipment Preventative maintenance should include keeping the product clean by protecting it from spillage contamination or corrosive environments If in doubt please confirm that any intended meth...

Page 8: ...ontamination certificate Copies of the Certificate are available from the Distributor Manufacturer At the end of its service life the product must be accompanied by a Decontamination Certificate Repairs and Support Any repairs or replacement of parts MUST be undertaken by suitably qualified personnel Only spare parts supplied or specified by Antylia Scientific or its agents should be used Fitting ...

Page 9: ...with Max 6kg of wax Temperature display range Ambient to 70ºC 1ºC at 20ºC ambient Display resolution 1ºC Accuracy 1 C Ceiling temperature setting 70 C Display Digital Display Control Sensor NTC Thermistor Electrical specification Total power consumption 480W Total power output 5A Temperature control On Off Oven operating temperature range Ambient to 70ºC 1ºC at 20ºC ambient Electricity supply 110 ...

Page 10: ...10 158 mm 455 mm 455 mm 181mm 181mm 420 5mm 79mm 455 mm ...

Page 11: ...so we cannot guarantee that interference will not occur in practise Where there is a possibility that injury damage or loss might occur if equipment malfunctions due to radio frequency interference or for general advise before use contact the manufacturer EU Representative address Antylia Scientific GmbH Futtererstraße 16 97877 Wertheim Deutschland Tel 49 9377 9203 0 Email sales coleparmer de UK R...

Page 12: ...antylia com W coleparmer fr Italy T 39 0 284349215 E it sales antylia com W coleparmer it India T 9122 61394444 E info coleparmer in W coleparmer in China T 1 847 549 7600 E sales antylia com W coleparmer com USA T 1 847 549 7600 E sales antylia com W coleparmer com Canada T 514 355 6100 E info antylia ca W coleparmer ca Other T 1 847 549 7600 Ordering Information Order No Series Model Legacy SKU ...

Reviews: