background image

5

Figure 3. Pump Drive — Rear Panel

CAUTIONS:

Use of Pump Heads other than those specified will result

in unsatisfactory performance, damage to the drive unit
and voiding of applicable warranties.

The drive system can only be used with one Pump Head
at a time. Use of this drive unit with multiple Pump Heads
will result in unsatisfactory performance, damage to the
drive unit and voiding of applicable warranties.

When mounting the Pump Head to the drive unit, the
mounting screws should only be tightened fingertight.
Excessive tightening of the mounting screws will result
in binding and unsatisfactory performance.

Tubing Accepted: The Pump Heads accepted for use with drive can be used
with MASTERFLEX precision tubing sizes L/S

®

 13, L/S

®

 14 and L/S

®

 16 in all

formulations. For L/S

®

 17 and L/S

®

 25 size tubing, use silicone or C-FLEX

®

formulations only.

Use only MASTERFLEX precision tubing with MASTERFLEX pumps to ensure
optimum performance. Use of other tubing may void applicable warranties.

Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

Summary of Contents for MasterFlex L/S 77200-00

Page 1: ...s underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos...

Page 2: ...4 800 MASTERFLEX 627 8373 847 247 2929 FAX www masterflex com e mail techinfo coleparmer com A 1299 0742 Edition 03 OPERATING MANUAL COMPACT PUMP DRIVES MODEL NOS 77200 00 77200 10 77200 12 Artisan Sc...

Page 3: ...turned off before proceeding Loose clothing could be caught in the drive EU Declaration of Conformity Name of Apparatus MASTERFLEX Compact L S Pump System Model Numbers 77200 00 10 12 Description of...

Page 4: ...th an External Power Supply which provides a DC output for connection to the Pump Drive Figure1 MASTERFLEX L S Compact Pump Drive The single turn adjustable Speed Control Figure 2 provides variable fl...

Page 5: ...bar For remote control by switch closure re move the shorting bar and connect the two terminals of an isolated remote control switch or relay to terminals 3 and 4 A closure of the remote switch contac...

Page 6: ...the drive unit the mounting screws should only be tightened fingertight Excessive tightening of the mounting screws will result in binding and unsatisfactory performance Tubing Accepted The Pump Head...

Page 7: ...e direction switch in the down position The POWER indicator should light and the fluid will flow from left to right To turn pump off place switch in the center position 6 The pump speed is controlled...

Page 8: ...ct closure connection at terminal strips 3 and 4 Construction Dimensions L W H 5 750 in 5 14 in 4 14 in 14 6 cm 13 0 cm 10 5 cm Weight 1 88 pounds 0 85 kg Material Painted Steel Enclosure Rating IP22...

Page 9: ...ced to you The warranty period for this product is noted on the Warranty Card PRODUCT RETURN To limit charges and delays contact the seller or Manufacturer for authoriza tion and shipping instructions...

Page 10: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: