Safety Warnings

 

 

Read all instructions before proceeding and observe the installation procedure and 

environmental/electrical requirements 

 

Anyone working with, on or around this equipment should read this manual 

. Failure to read, 

understand and follow the instructions given in this documentation may result in damage to the 

unit, injury to operating personnel and/or poor equipment performance 

 

Any internal adjustment, modification or maintenance to this equipment must be undertaken by 

qualified service personnel. 

 

The use of any hazardous material in the cabinet must be monitored by an industrial hygienist, safety 

officer or some other suitably qualified individual. 

 

Explosive or inflammable substances should never be used in the cabinet unless a qualified safety 

professional has evaluated the risk involved 

 

If chemical, radiological or other non-microbiological hazards are being used in the cabinet, additional 

protective measures should be taken 

. Additionally, the operation should be monitored by a suitably trained 

individual 

 

If the equipment is used in a manner not specified by this manual, the protection provided by this 

equipment may be impaired 

 

Even with the benefits they provide, germicidal ultraviolet lamps pose imminent danger if used without taking the 

proper precautions 

. You 

MUST 

avoid exposure to direct or reflected germicidal ultraviolet rays, since they cause 

painful eye irritation and reddening of the skin . In order to use our direct germicidal UVC products, you 

MUST 

wear 

personal protection equipment—gloves, a long sleeve shirt with no gaps between cuffs and gloves and an 

ultraviolet-blocking face shield to protect eyes and exposed skin 

. Under no circumstances should any direct 

germicidal UVC unit be permitted to operate with humans, plants or animals present in the operation area 

 

Symbols

 

 

 

Warning of hazardous area or situation 

 

 

Limitation of Liability

 

The disposal and/or emission of substances used in connection with this cabinet may be governed by various local 

regulations 

. Familiarization and compliance with any such regulations are the sole responsibility of the users of the 

cabinet 

. The liability of Cole-Parmer

® 

is limited with respect to user compliance with such regulations 

 

European Directive on Waste Electrical and Electronic Equipment (WEEE)

 

At the end of your product / accessories life, it must not be discarded as domestic waste . Ref: EU 
Directive 2012/19/EU on Waste Electrical and Electronic Equipment Directive (WEEE) 

. Please contact 

your distributor / supplier for further information . For end users outside of the EU consult applicable 
regulations . 

 

 

 

Summary of Contents for 78902-20

Page 1: ...Cole Parmer FHD 400 Series Ductless Fume Hoods USER OPERATION MANUAL 78902 20 78902 21 78902 22 78902 23 78902 24 78902 25 78902 26 78902 27...

Page 2: ...tance of Performance Validation Certification 15 3 7 Disclaimer 15 IV Operating Your Cabinet 16 4 1 Control System 16 4 2 Cabinet Operating Procedure 17 V Monitoring 18 5 1 General 18 5 2 Manual Monit...

Page 3: ...th the benefits they provide germicidal ultraviolet lamps pose imminent danger if used without taking the proper precautions You MUST avoid exposure to direct or reflected germicidal ultraviolet rays...

Page 4: ...THERE ARE NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WHICH EXTEND BEYOND THE DESCRIPTION AND PERIOD AS STATED IN THE...

Page 5: ...llet is designed to protect the cabinet from any foreseeable circumstances However excessive impact on the boxes or pallet may also damage the cabinet Prevent any direct impact or hitting to the palle...

Page 6: ...t discard the packaging material for your cabinet until you have checked all of the components installed and tested the unit 7 Lifting the Cabinet The cabinet can be lifted in two sections The HEAD un...

Page 7: ...he face velocity of the filter the potential exists for contaminated air to enter the work zone of the cabinet A minimum distance of 50 cm 20 in to the top of the ceiling is recommended for blower cha...

Page 8: ...g Your Cabinet 1 Please refer to unpacking your cabinet 2 Inspect your cabinet carefully Should you find any defect please refer to the warranty Peel off any protective masking that was left on the ca...

Page 9: ...age alarm Prior to beginning assembly ensure the following 1 Area is free of obstructions tripping hazards etc 2 Ample clearance is available on sides and over head 3 Appropriate number of personnel a...

Page 10: ...de of the unit and any adjacent wall to allow the detachable power supply cord to be disconnected from the power source Warning Tipping Hazard Please ensure that all end rails of unit are completely o...

Page 11: ...r 7 Place the wheels of the main carbon HEPA filter on the track and push all the way in If unit has separate HEPA and carbon filters stack the carbon filter on top of the HEPA filter and install 8 On...

Page 12: ...or wires Install the sensor by attaching to the enclosure with the screw and nut 12 If not already installed slide polypropylene spill tray into the enclosure The side with the extended handle lip sho...

Page 13: ...either side of the enclosure as required Ensure that the side not to be used has the airflow opening covered by the supplied blanking plate The side to be used should have an open hole to fit the met...

Page 14: ...allow cables and hoses to be fed inside of the enclosure as required refit the yellow caps when the holes are not in use 16 To calibrate the filter blockage alarm see Calibration use a small Phillips...

Page 15: ...ort It is recommended that these tests be performed only by a qualified technician who is familiar with the methods and procedures for certifying these types of cabinets 3 6 Importance of Performance...

Page 16: ...key for 4 seconds when an audio beep is observed release the mute switch 3 Using a calibrated anemometer set the airflow to the desired velocity 4 Using the up and down arrows set the display to read...

Page 17: ...he filter block may temporarily reduce the efficiency of the filter For this reason any major spillage must be cleared up immediately preferably using spillage absorption granules rather than paper wh...

Page 18: ...h at the correct operating height using an anemometer such as a hot wire vane anemometer or propeller type Depending on the size of the cabinet a series of readings are to be taken at the front openin...

Page 19: ...uld also be noted that fume cabinets are sometimes used to contain and protect users of the cabinet from hazardous or harmful substances Before commencing this schedule it is important to ensure the c...

Page 20: ...strokes for each type of tube If a significant level of chemical is recorded at the outlet the filter must be changed It is also worth checking the gasket condition for any damage that may result in a...

Page 21: ...pecialist company NOTE CONSULT YOUR SAFETY OFFICER OR INDUSTRIAL HYGIENIST BEFORE REMOVING OR DISPOSING ANY FILTERS Pre Filters The pre filter is located below the main filter Remove the perforated pr...

Page 22: ...ularly the front and top of the cabinet to remove any accumulated dust When needed use soap or other mild household detergent Quarterly 1 Replace pre filters 2 All monthly activities Semiannually 1 Re...

Page 23: ...k Filter Blockage Alarm Check airflow at aperture Check pre filter is not blocked Check fan is running Recalibrate Filter Saturated Optional Check filter condition with Gastec or Draeger test kit Chec...

Page 24: ...ight Units To change a light unit use the following instructions 1 Ensure the power cord has been disconnected from the wall outlet 2 Using the key supplied unlock both ends of the blue cover door to...

Page 25: ...combined together with any of our activated carbon filters 7 1 Filter Descriptions 78902 35 FHD 400 Ductless Fume Hood carbon filter for organic vapors including solvents and hydrocarbon vapors units...