background image

Setting the timer

Enable the timer

 

    

         

        

          

Press

 “Switch”

 key until the 

“Set”

 indicator on the timer setting section flashes and the

         system will enter into timing function setting status;
         When in timing function setting status, user can touch and move finger on the 

“Touch 

         wheel”

 to adjust the timing with the adjustable increment of 5 minutes and the  time 

         range of 0 

-

 9 hours; 

When finished setting, press   

     

(Start/Stop)

 to start countdown with the 

timer 

         indicator

         shown on the LCD screen. 

.

       

      

         

The remaining time shows on the LCD

          

2

3

1

     

 

 

        

Disable the timer

         If user wants to disable the timer, user can press 

“Switch”

 key until the 

“Set”

 indicator on the timer setting section flashes and the system 

will enter into timing function setting status

Press  

     

(Start/Stop)

 to stop countdown with the

 timer indicator

     

  

disappear from 

         the

 

LCD screen.

Switch off and data saving

        

O

Power off

Press  

    

(Power on/off)

 then the device will go on standby and the 

“Standby”

 indicator will lit.

        Set the power switch on the back of the device to the 

 

 position, the 

“Standby”

 indicator will go out and the device will be turn 

        off.
        
        

          

 

2

1

Notice

Unplug the instrument from the electric outlet if being unused for a long period of time.

        
        

          

Auto save function

When using 

    

to turn off the instrument, the  set speed / set time will be saved automatically and the system will automatically restore 

the previous settings next time  when user restart the instrument.
        
        

          

20

Summary of Contents for 04661-29

Page 1: ...User manual 04661 43 04661 44 04661 45 04661 46 04661 39 04661 40 04661 41 04661 42 04661 29 04661 30 Magnetic Stirrer with Heating Stir Timer Stir Heat Stir Timer Heat Magnetic Stirrer ...

Page 2: ......

Page 3: ...shooting guide Technical data 04661 29 04661 30 Model Switching on Plate overview Setting stirring speed and reverse mode Setting the timer Switch off and data saving Troubleshooting guide Technical data 3 3 1 2 4 5 6 7 8 9 10 11 12 13 15 16 17 18 19 20 20 21 22 Warranty Standard accessories Stirring bar 1 Power line 1 Switch off and data saving 12 User manual 1 User manual 04661 43 04661 44 04661...

Page 4: ...r bar Release of toxic or flammable gases Place the instrument on a stable clean anti slip dry and fireproof surface Ensure the base of instrument is clean and intact Check and ensure the instrument and accessories remain intact before each use Do not use damaged components Slowdown the speed if The medium splashes out of container in high speed The container shifts on the plate Beware of hazards ...

Page 5: ...alling accessories The instrument can only be disconnected from the power supply by pulling out the power plug Caution Do not spill corrosive liquids on the instrument Do not use the instrument under water Caution High voltage The appliance should be opened only by professionally trained maintenance and repair personnel The mains voltage must be in accordance with the voltage marked on the namepla...

Page 6: ...ent Warranty This instrument is warranted for a period of 24 months from the date of invoice For claims under the warranty please contact Cole Parmer After receiving confirmation from our warranty department you will be liable for freight costs The warranty does not cover normal wear and tear of parts or accessories nor does it apply to improper use abnormal operation or insufficient maintenance w...

Page 7: ... support rod into the tapped hole until the end stop is reached Using a wrench to tighten the nut on the support rod Install horizontal head clamp and horizontal holding rod as illustrated Install external temperature sensor 6 04661 43 04661 44 04661 39 04661 40 04661 45 04661 46 04661 42 04661 41 Model 4 Pt1000s Slotted hole Support rod Horizontal holding rod Horizontal head clamp Support rod Scr...

Page 8: ...of the device to the O Power off position Connect the power line If using external temperature sensor to measure temperature of the medium please plug the sensor connector into the sensor interface on the back of the instrument Preparation before start up C 1 2 1 2 Powersocket Switching on Set the power switch to the Power on position and the Standby indicator will be lit and the system enters int...

Page 9: ... 43 04661 44 04661 46 04661 45 Power on off Touch wheel Start Stop Function key Hot warning indicator Switch LCD display 04661 43 04661 44 04661 39 04661 40 04661 45 04661 46 04661 42 04661 41 Model Setting temperature Item Designation Plate safety temperature icon Real time temperature 4 Key lock icon 5 Heating icon Dynamical 6 External sensor icon 7 Heating plate icon 8 Stirring icon Dynamical 9...

Page 10: ... setting operation status The LCD screen will be lightened and Plate safety temperature icon will flash showing that the system is now in the setting area of plate safety temperature 3 After the safety temperature is finished press Start Stop or Switch key to record and save the safety temperature setting and system will automatically switch to heating temperature setting area If the safety temper...

Page 11: ...system will not perform the heating operation 3 Do not heating the hotplate without Liquid in the container actual measured by the temperature sensor 04661 45 04661 46 04661 41 04661 42 04661 43 04661 44 04661 39 04661 40 Model Plate temperature setting range Room temperature 340 C Room temperature 260 C Sensor temperature setting range Room temperature 320 C Room temperature 160 C 4 During the he...

Page 12: ...ashes and the system will enter into stirring speed setting status When the stirring speed setting is switched on then touch and move your finger around the Touch wheel clockwise counterclockwise to adjust the stirring speed 1 2 2 3 Press Start Stop to start stirring and the stir indicator will be shown on and rotate 4 During the stirring user can repeat the above 1 2 steps to alter the speed sett...

Page 13: ...one can press the function key to activate the reverse stirring mode and the Reverse Intermittent stirring mode indicator will be shown on The stir bar will reverse stirring direction every 45 seconds with a 5 second break before every change 2S 2S Inactivate When the reverse stirring mode is active press to turn off reverse stirring function and the Reverse Intermittent stirring mode indicator wi...

Page 14: ...Timing stirring function If there is only stirring function activated before user sets the timer user can press Start Stop to active stirring timer the timer indicator and the stirring indicator will be shown on the LCD screen simultaneously and the device goes on stirring until the timer countdown finishes TIME Set TIME Set Timing stirring heating function If both stirring and heating functions a...

Page 15: ...he device will be turn off 2 1 Notice Unplug the instrument from the electric outlet before left it unused for a long period of time When the temperature of the hotplate is higher than 50 C even after the device is shut down the Hot warning indicator will not stop flashing until the temperature of the hotplate is lower than 50 C Risk of burns Notice Unplug the instrument from the electric outlet b...

Page 16: ...recommended for model Irregularities in the shape of the stir bar and of the bottom of the container Increase or decrease the speed until the stir bar begins to rotate evenly The material of the container is Fe or Cu which will be magnetized Use glass or 304 stainless steel container Stir bar does not rotate If container diameter is same as stir bar length When stirring speed is slow stir bar touc...

Page 17: ...nnel can carry out an internal checking on the heating part s Heating circuit malfunction Motor control circuit malfunction Heating function shutdown Motor shutdown Turn off the device Warning Only an authorized maintenance and repair personnel can carry out an internal checking on the motor Heating function shutdown Turn off the device Warning Only an authorized maintenance and repair personnel c...

Page 18: ...heated Turn off the device Warning Only an authorized maintenance and repair personnel can carry out an internal checking on the temperature sensor Surface temperature of the base plate is higher than the set safe temperature Troubleshooting guide Difference between temperature of safety sensor and temperature of control sensor is larger than 20 C when heated Switch off device until the surface te...

Page 19: ...t mode 45 seconds Heating power output 600W 300W Heating temperature increases speed 1L H2O 6 5 C min 3 5 C min Plate temperature setting range Room temperature 340 C Room temperature 260 C Sensor temperature setting range Room temperature 320 C Room temperature 160 C Safety temperature setting range 50 360 C Plate temperature control accuracy 5 C External temperature sensor Pt1000 accuracy 1 C Ti...

Page 20: ......

Page 21: ...04661 29 04661 30 Stirr Timer User manual Magnetic Stirrer ...

Page 22: ...idity according to the technical parameters in this manual Set the power switch on the back of the device to the O Power off position Connect the power line Preparation before start up C 1 2 1 2 Powersocket Switching on Set the power switch to the Power on position and the Standby indicator will be lit and the system enters into standby status Press Power on off to activate the instrument and then...

Page 23: ... Setting indicator 7 Timer setting time 8 7 6 1 2 3 4 9 5 How to use the touch wheel Touch and move your finger around the Touch wheel clockwise counterclockwise follow the direction of the arrow to adjust the setting of different configuration with the adjustable increment The faster the movement of the finger the larger the adjustment of the setting parameter and vice versa so that one can rapid...

Page 24: ...r on the stir setting section flashes and the system entering into stirring speed setting status then press Start Stop to stop stirring and the stir indicator will disappear stirring When the stirring function is switched on one can press the function key to activate the reverse stirring mode and the reverse stirring mode indicator will be shown on The stir bar will reverse stirring direction ever...

Page 25: ... until the Set indicator on the timer setting section flashes and the system will enter into timing function setting status Press Start Stop to stop countdown with the timer indicator disappear from the LCD screen Switch off and data saving O Power off Press Power on off then the device will go on standby and the Standby indicator will lit Set the power switch on the back of the device to the posi...

Page 26: ...pecifications and models Use stir bar recommended for model Irregularities in the shape of the stir bar and of the bottom of the container Increase or decrease the speed until the stir bar begins to rotate evenly The material of the container is Fe or Cu which will be magnetized Use glass or 304 stainless steel container Stir bar does not rotate If container diameter is same as stir bar length Whe...

Page 27: ...80 10 70 C IP 42 04661 29 04661 30 Model Maximum stirring quantity H2O 20L Motor output 5W Rotation Speed range 100 1800RPM 45 seconds Timer 0 9 huors Display LCD Stirring bar length range 20 80mm Heating Plate Material Aluminum alloy ceramic coating Heating Plate Size O 135mm Dimensions W x D x H 175 x 270 x 76mm Weight 2kg 30W Reverse of rotation direction 22 ...

Page 28: ...Toll Free 1 800 323 4340 Phone 1 847 549 7600 Fax 1 847 247 2929 Coleparmer com ...

Reviews: