DOMUSFIRE C29 - C35
18
button
description
mode
action
top display
bottom display
limits
SET TEMPERATURE
Increase the WATER AND AMBIENT
thermostat temperature value
SET H2O/air
Temperature
air 7°C ÷ 40
°C water
30°C ÷ 80
°C
PROGRAMMING
Increase the selected parameter
Selected
parameter
Parameter value
-
1
Increase
temperature
WORK
Display temperatures
Fume temperature
Water temperature
-
SET TEMPERATURE
Decrease the water and ambient thermostat
temperature value
SET H2O/air
Temperature
air 7°C ÷ 40
°C water
30°C ÷ 80
°C
PROGRAMMING
Decrease the selected parameter
Selected
parameter
Parameter value
2
Decrease
temperature
WORK
Display stove operation status
Pressure in water
circuit
fume fan speed
3
Set/Menu
-
Access the SET temperature and the user
and technician parameters menu with
successive pressing
SET/parameter
Temperature/value
WORK
Press for 2 seconds to turn the stove on or
off, if off or on respectively.
Display current
status
BLOCK
Reset the stove, returning it to off status
OFF
4
ON/OFF Reset
PROGRAMMING
Use to exit the programming menu at any
stage of the modification. Modifications are
saved.
5
Decrease power
WORK/OFF
Decrease the power or the DHW storage
tank water thermostat Temperature value (if
enabled)
Power level
SET DHW
temperature
1-5
6
Increase power
WORK/OFF
Increase the power or the DHW storage
tank water thermostat Temperature value (if
enabled)
Power level
SET DHW
temperature
1-5
The Figure opposite describes the meaning of the status
indicators in the left part of the display.
Activation of one of the segments on the display signals
activation of the corresponding device according to the
list opposite.
4.3 Lighting
4.3.1 Check before lighting
Before lighting the boiler:
- make sure to have read and understood the information given in the manual;
- the hopper must be filled with pellets;
- the combustion chamber must be clean;
- the brazier must be completely free, cleaned of any combustion residuals and correctly fitted in the brazier
holder;
- check hermetic closing of the ash box and fire door;
- check the connection of the power cable and switching to ON/1 of the switch located on the back of the boiler.
- check opening of the delivery and return shutoff valves as well as the water circuit pressure.
- At first startup, remove all the components that could burn (instructions/label) from the boiler firebox.
- Any lighting done after long idle periods requires the removal of any residual pellets that have remained
inside the hopper, in being damp fuel no longer suitable for combustion, and complete cleaning of the
combustion chamber.
External contact
Chrono
Heater
Auger
Fume extractor
DHW circuit activation
HEATING circuit activation
ALARM