47
1. 2-colour indicator light:
- Plugged in:
Green LED
-Resistance heating:
Red LED
- Anti-Legionella Function Flashing LED (green or red, as applicable)
2. STANDBY button
3. “-” button
4. Temperature indicator lights:
Red LEDs
5. “+” button
6. Smart function button
7. Smart function indicator light:
Red LED
Plug the heater into a 230 V / 50 Hz power outlet. The first time it is plugged in, the two-colour LED (
1
) will light
up green. Press the
STANDBY
button (
2
) to switch on the unit. The first time the unit is switched on, the
temperature will be pre-set to 70 ºC.
During the warm-up phase, the LEDs that display the temperature reached by the water remain light up per-
manently, whereas the subsequent LEDs flash until the set temperature is reached (they stop flashing once
the temperature is reached and remains constant).
If the temperature drops, for example after hot water has been used, it automatically starts to heat water again
and the LEDs between the last fixed light and the light displaying the temperature setting will resume progres-
sively.
During the warm-up phase, you may hear a slight noise as a result of the water heating process.
The TL plus heater has 2 operating modes: Manual and Smart.
MANUAL OPERATION:
This enables the user to adjust the temperature using the "
+
" y "
-
" until indicated with the LEDs, selecting a
temperature level between 40 ºC and 80 ºC (40 ºC, 50 ºC, 60 ºC, 70 ºC and 80 ºC).
SMART FUNCTION:
Press the
to activate the "smart" function. The Smart function LED indicator (
7
) will light up.
If the "manual'' function is used in conjunction with the "smart" function, the temperature will automatically be
adjusted by the product; this means that the “Manual” function will be deactivated.
To switch off the function, press the button
; and the smart LED will go off. If you want to adjust the tem-
perature manually, you will need to turn off the smart function.