background image

9

6X-1086

3230 CAMERA

INSTALLATION MANUAL

2.  Ceiling mount (CEIL). This mounting arrangement 

uses a ceiling mount arm to which the camera is 

secured. See figure 3.

3.  Pole Mount (POLE). When the camera must be 

mounted to a pole this option provides both a clamp 

to attach to the pole and also the heavy duty wall 

mount (HDWM) on which to fasten the camera (See 

figure 3). 

4.  Mast Mount (MAST). A mast mount  attaches to 

a horizontal arm using stainless steel straps. (See 

figure 3.)

5.  Heavy Duty Wall Mount (HDWM). This mounting 

arrangement uses a wall mount arm designed for 

rugged duty use (See figure 3).

The following paragraphs describe some of 

the features of the 3230 related to the installation 

process.

2.9  Installation Procedure

It is important to carefully plan for all cable 

routing before starting an installation. In some situ

-

ations cable will have to be pulled through conduit 

or other narrow places before adding a connector to 

the end of a system cable.  Any through-wall holes 

may require weatherproofing.

Installing the 3230 is straightforward. It is only 

necessary to mount the 3230 to a suitable base,  

mate the cable connector to the system cable and 

apply power. (Or connect to the camera with an 

on-site cable.) This assumes the other end of the 

cable is properly connected to a source of power, a 

tv monitor, a graphical user interface (GUI), and any 

other required equipment.

2.9.1  Camera Rear Panel Features

Three features on the rear panel are of interest 

when installing the camera.

2.9.1.1  18-pin MS Connector

An 18-Pin MS connector on the rear panel 

provides for all interconnections with the camera. A 

mating plug kit is supplied for the system cable con

-

necting to this rear panel connector.

2.9.1.2  Schrader Valve

A Schrader valve (figure 7 — the car tire type 

air valve on the left) on the rear panel provides for 

pressurizing the housing with dry nitrogen. This 

valve can be used to occasionally add dry nitrogen 

as necessary to maintain pressure in the barrel at 

about 5 psig (34 kPa).  (Note: psig refers to pounds 

square inch gauge — which designates pressure 

relative to the altitude above sea level at which it is 

being measured.)

2.9.1.3  Pressure Relief Valve

The pressure relief valve has a short piece of 

clear tubing slipped around it to prevent acciden

-

tal movement of the pop out valve — which would 

release nitrogen from inside the valve.

During shipping, at which times high altitude 

might be encountered during aircraft transportation, 

a pressure relief valve on the rear panel (figure 7) 

may release some pressure. Back at low altitudes 

this would be experienced as a housing pressure 

below the standard 5 psig (34 kPa). 

Table 3.  Items Typically Requried but not 

Supplied

ITEM

DESCRIPTION

CHARACTERIS-

TICS

1

Support Base

See figure 5

2

Cable

Power, RS-232 or RS-

422, 75-ohm Coax

3

Source of power

12 V dc, 24 V ac/dc, or 

115 V ac, depending 

on model

4

TV Monitor

75 ohm, NTSC or PAL, 

as required

5

PC, Laptop, or oth

-

er control method

RS-232, RS-422 Serial 

Output or converters

 6

Serial Converte

r

232 / 422 converter

(see figure 6)

- end table -

Table 2.  Items Supplied

ITEM

DESCRIPTION

CHARACTERIS-

TICS

1

Camera with sun

-

shield

Model 3230 series

2.

Connector Kit

1310230-011

Note: See figure 9 for the kit. This kit contains items to con

-

struct  a  cable  plug  that  mates  with  the  camera  rear  panel 
connector.

Summary of Contents for 3230 series

Page 1: ...3230 SERIES ANALOG ENVIRONMENTAL CAMERA INSTALLATION MANUAL Technical Manual 6X 1086 March 21 2008 Figure 1 Model 3230 NTSC or PAL Camera RS 232 RS 422...

Page 2: ...able 1 Manual 6X 1084 The setup GUI for configuring camera characteristics 2 Manual 6X 1085 The protocol for use by programmers to write software for controlling camera functions CAUTION Do not power...

Page 3: ...ressurized camera module Dry nitrogen is used for the presssurization Dry desiccant packs are placed inside the camera during during the sealing process An integral sun shield over the camera housing...

Page 4: ...tly but these are not common devices 2 5 RS 422 and RS 232 Wiring Cable diagrams in this manual show pin func tions for both RS 232 and RS 422 connections Only one of these communications methods can...

Page 5: ...OUNT HEAVY DUTY WALL MOUNT NONE None Supplied PEDD Pedestal Mount CEIL Ceiling Mount POLE Pole Mount MAST Mast Mount HDWM Heavy Duty Wall Mount Note Read the table horizontally A dot designates an ite...

Page 6: ...ductor shielded cable must be used with this camera both to minimize EMI radiation and to reduce susceptibility to interference The cable must have an overall shield with at least 95 percent coverage...

Page 7: ...6X 1086 3230 CAMERA INSTALLATION MANUAL Figure 5 Dimensions Model 3230 Camera Camera Sunshield Dimensions...

Page 8: ...lation to power input requirements 1 The model 3232 operates from 12 V dc 10 percent 2 The model 3234 operates from either 24 V ac or 24 V dc 10 3 The model 3235 operates from 115 V ac 10 Power consum...

Page 9: ...el provides for all interconnections with the camera A mating plug kit is supplied for the system cable con necting to this rear panel connector 2 9 1 2 Schrader Valve A Schrader valve figure 7 the ca...

Page 10: ...d through any conduit or other re stricted passage on its way to the mounting location of the 3230 Or the cable could be pulled through conduit in the opposite direction if the other end has stripped...

Page 11: ...connec tors The web site for Coax Seal has complete infor mation about this product 3 0 CAMERA SETUP A GUI specific to the model 3230 provides all setup communications A separate manual describes fea...

Page 12: ...eners and a repositionable head at the bottom end to which the camera can be bolted for movement up down and right left 4 3 Pole Mount POLE The pole mount figure 11 attaches to vertical poles using st...

Page 13: ...AL Figure 9 Type 1310230 011 System Cable 18 pin MS Type Connector Kit Kit as Typically Packaged Connector Kit Contents Wiring Side Solder Cups Front Side Mating Sockets Connector Plug for the System...

Page 14: ...tock on the work bench surface 2 Connect the sheet stock to ground through a 1 megohm or greater value resistor 3 Use a wrist strap connected to ground through a 1 megohm or greater value resistor whe...

Page 15: ...15 6X 1086 3230 CAMERA INSTALLATION MANUAL Figure 10 Dimensions PEDD and CEIL Mounts Figure 11 Dimensions POLE Mount...

Page 16: ...16 6X 1086 3230 CAMERA INSTALLATION MANUAL Figure 12 Dimensions MAST Mount Figure 13 Dimensions HDWM Mount...

Page 17: ...BNC stripped leads RJ 45 24 V AC dc 19 CA 292A RS 232 stripped leads stripped leads stripped leads 20 CA 292B BNC stripped leads D9S 21 CA 293A RS 422 stripped leads stripped leads stripped leads 22 C...

Page 18: ...18 6X 1086 3230 CAMERA INSTALLATION MANUAL Figure 16 Type CA 254A System Interconnection Cable Figure 15 Type CA 253B System Interconnection Cable...

Page 19: ...19 6X 1086 3230 CAMERA INSTALLATION MANUAL Figure 18 Type CA 254M System Interconnection Cable Figure 17 Type CA 254B System Interconnection Cable...

Page 20: ...20 6X 1086 3230 CAMERA INSTALLATION MANUAL Figure 20 Type CA 292B System Interconnection Cable Figure 19 Type CA 292A System Interconnection Cable...

Page 21: ...21 6X 1086 3230 CAMERA INSTALLATION MANUAL Figure 22 Type CA 293B System Interconnection Cable Figure 21 Type CA 293A System Interconnection Cable...

Page 22: ...22 6X 1086 3230 CAMERA INSTALLATION MANUAL Figure 24 Type CA 295E System Interconnection Cable Figure 23 Type CA 293M System Interconnection Cable...

Page 23: ...23 6X 1086 3230 CAMERA INSTALLATION MANUAL Figure 26 Type CA 295G System Interconnection Cable Figure 25 Type CA 295F System Interconnection Cable...

Page 24: ...24 6X 1086 3230 CAMERA INSTALLATION MANUAL Figure 28 Type CA 296A System Interconnection Cable Figure 27 Type CA 295M System Interconnection Cable...

Page 25: ...25 6X 1086 3230 CAMERA INSTALLATION MANUAL Figure 30 Type CA 296C System Interconnection Cable Figure 29 Type CA 296B System Interconnection Cable...

Page 26: ...45 Signal to Noise 48 dB Lens Zoom 30x optical zoom 3 3 mm to 99 mm f 1 6 to f 3 2 Lens Focus Auto manual selectable Digital Zoom Up to 10x with smooth transition produces effective digital focal len...

Page 27: ...RS 422 4 wire half duplex RS 232 half duplex Environmental Temperature Operating 50 to 60 C 58 to 140 F Protection Rating Storage 30 to 60 C 22 to 140 F Humidity Up to 100 percent relative Altitude S...

Page 28: ...shall be repaired or replaced without charge This Warranty does not extend to Cohu equipment subjected to misuse accident neglect improper applica tion or repaired or altered other than by Cohu or unl...