Set the Wall Connector as Slave by placing the rotary switch in F position.
Crimp the supplied RJ10 4P4C connector on Maxem side on the data cable. Two wires
must be connected:
•
Connect wire 1 (orange-white) to Pin 1
•
Connect wire 2 (orange) to Pin 2
Connect the RJ10 4P4C connector to RS2 Maxem port.
Connect the data cable to the IN (D+ and D-) port of the Wall Connector
clamp block:
•
Connect the wire from pin 1 on D+
•
Connect the wire from pin 2 to D-
RS2 port for
Tesla Wall Connector
LED indications Tesla Wall Connector
RS2
Pin 1
Pin 2
LED above lights up in green: everything is connected properly
Middle LED is blinking red: set as Slave but no connection with Maxem
Lower LED burns 5 secs. green: correctly set as Slave at start
RJ10 4P4C
See installation manual Tesla Wall Connector for more information
Tab above
Option 4.3 - Connecting Tesla Wall Connector
Install a circuit breaker or earth leakage circuit breaker for each charging
station at the maximal power available.
See p. 10.
Follow the installation instructions of the charging station. These
instructions can be found in the installation manual of the charging
station.
Place a suitable UTP (CAT5 or CAT6) of the Wall Connector to Maxem. (To prevent
electromagnetic interference at the RS485 connection, it is recommended to use FTP
CAT6 cable at distance more than 25 m. Max: 50m).
SET
OK
1 2 3
Connect the RS485 cable to the kWh-meter as follows:
•
Port C: Green core
•
Port B: White core
•
Port A: Brown core
Place the kW-meter on a DIN rail in the installation cabinet.
Distribution board
Chargin station
Direction of current
Connect it in such a way that it measures the consumption of the charging station.
Connection of RS485 cable
to kWh-meter
Set the addressing of the kWh-meter to 002. As a result, Maxem can configure itself.
See Annex 2 how to set the addressing.
18
19
A.
B.
C.
D.
E.
F.
J.
I.
H.
G.
L.
Tesla Wall Connector does not measure kWh itself, therefore a MID
kWh-meter is needed.
Cores for pull relief
Connect the RS485 cable to RS1 port on Maxem.
A
A
167
184
55.50
SECTION A-A
Client:
Rev. nr:
1:1
Units:
1/2
CES-01 - Enclosure
MH
Vol. (mm³):
mm
Sheet:
Scale:
-
Cohere
Date:
Drawn:
File reference:
Drawing name:
-
Material:
17-02-2016
Maxem 4 Assembly
A3
Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]
<0,2x45° or R<0,2
Ra 0,8 um
Default length tolerances: DIN 7168
±20'
Default angle tol.:
Finish:
Default edges:
Roughness:
Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8
Dim.: 0-6 7-30 31-120 121-400 401-1000
RS1
D.
RS1 port for
MID kWh-meter