background image

Device Distances in mm/1D min. code

16 mm lens

Distances in mm/1D min. code

25 mm lens

Distances in mm/1D min. code

35 mm lens

DM503

250

5 MIL

400

5 MIL

460

5 MIL

480

10 MIL

750

10 MIL

1070

10 MIL

620

13 MIL

970

13 MIL

1380

13 MIL

710

15 MIL

1120

15 MIL

1580

15 MIL

Connecting the Reader

Perform the following steps:

1.

Mount the reader.

2.

Connect the Ethernet cable to a computer or a switch.

3.

Connect the breakout cable.

10

Summary of Contents for DataMan 503

Page 1: ...DataMan 503 Quick Reference Guide 2021May26 Revision 6 1 10 SR1 3 ...

Page 2: ...at the cable bend radius begins at least six inches from the connector Cable shielding can be degraded or cables can be damaged or wear out faster if a service loop or bend radius is tighter than 10X the cable diameter l This device should be used in accordance with the instructions in this manual l All specifications are for reference purposes only and can change without notice l This product is ...

Page 3: ...view 1 External illumination mounting point 2 Mounting holes M3 x 5mm 3 Trigger button 4 Power 5 Train status 6 Good bad read 7 Network 8 Error 9 Tuning button 10 Peak meter 11 Synchronized Acquisition 12 RS 232 3 ...

Page 4: ...13 External light control 14 Ethernet 15 Power I O 4 ...

Page 5: ...R CLRB CLRO CLRS CLRD illumination External light control cable for DataMan 5 meters in length with flying leads CCB M12XFLY 05 Bar light cable xxx specifies length 300 500 1000 2000 mm IVSL 5PM12 Jxxx Compatible with IVSL lights except IVSL LX280 I O extension cable 5m straight CKR 200 CBL EXT Power cable for multiple bar lights use in combination with IVSL 5PM12 5 CCB FOV25 MAL 012 RS 232 M8 to ...

Page 6: ...Xpand 15 DMA FOVE 15 Xpand 25 DMA FOVE 25 SVL Light Bar IVSL YLW300 xxx Bar light blue IVSL LX520 470 Bar light red IVSL LX520 650 DM503 high power illumination DM503 HPIA xxx 6 ...

Page 7: ...Dimensions 7 ...

Page 8: ...ng Distances 16 mm lens for 1D codes green 25 mm lens for 1D codes blue 35 mm lens for 1D codes red Device Distances in mm 1D min code 16 mm lens Distances in mm 1D min code 25 mm lens Distances in mm 1D min code 35 mm lens 8 ...

Page 9: ...DM503 500 5 MIL 790 5 MIL 1100 5 MIL 980 10 MIL 1530 10 MIL 1270 13 MIL 1990 13 MIL 1460 15 MIL 16 mm lens for 1D codes green 25 mm lens for 1D codes blue 35 mm lens for 1D codes red 9 ...

Page 10: ...code 35 mm lens DM503 250 5 MIL 400 5 MIL 460 5 MIL 480 10 MIL 750 10 MIL 1070 10 MIL 620 13 MIL 970 13 MIL 1380 13 MIL 710 15 MIL 1120 15 MIL 1580 15 MIL Connecting the Reader Perform the following steps 1 Mount the reader 2 Connect the Ethernet cable to a computer or a switch 3 Connect the breakout cable 10 ...

Page 11: ...For information on the cable pinout and wire colors see section Connections Optics and Lighting in the DataMan 503 Reference Manual 11 ...

Page 12: ...the following to access the manual All Programs Cognex DataMan Software vx x x Documentation Note l Cables are sold separately l If a standard component is missing or damaged immediately contact your Cognex Authorized Service Provider ASP or Cognex Technical Support CAUTION All cable connectors are keyed to fit the connectors on the DataMan system do not force the connectors or damage may occur 12...

Page 13: ... your network 3 Connect the cable to a 24V power supply To configure a DataMan 503 reader the DataMan Setup Tool software must be installed on a networked PC The DataMan Setup Tool is available from the DataMan support site http www cognex com support dataman 1 After installing the software connect the DataMan 503reader to your PC 2 Launch the DataMan Setup Tool and click Refresh 3 Select your Dat...

Page 14: ...es 1 D barcodes Codabar Code 39 Code 128 and Code 93 Interleaved 2 of 5 MSI Pharma GS1 DataBar Postal UPC EAN JAN 2 D barcodes Data MatrixTM IDMax ECC 0 50 80 100 140 and 200 IDQuick ECC200 QR Code and microQR Code RSS CS PDF 417 MicroPDF 417 Discrete I O operating Limits HS Output 0 1 IMAX 24 VDC 50 mA RMAX 12 VDC 150 Ω 24 VDC 470 Ω Input 0 Trigger Input 1 VIL 0 7 V ITYP 12 VDC 2 0 mA 24 VDC 4 2 ...

Page 15: ...Power Supply Requirements 24V 10 Maximum current 500 mA at 25ºC Maximum power 18W external lights Ethernet Speed 10 100 1000 Duplex Mode Full duplex or half duplex 15 ...

Page 16: ...er Specifications Specification DataMan 503 Imager Image Sensor 2 3 inch CMOS Image Sensor Properties 5 5μm square pixels Image Resolution Pixels 2048 x 1088 Image Acquisition Maximum 150 fps Lens Type C mount lens 16 ...

Page 17: ...y information see the Cognex support site cognex com support Safety and Regulatory European Compliance This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take immediate measures This equipment complies with the essential requirements of the EU Directive 2014 30 EU Declarations are available from your local represe...

Page 18: ...tions Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at personal expense Canadian Compliance This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada C Tick Statement Conforms to AS NZS CISPR 22 EN 55022...

Page 19: ...ct you are disposing in a sound way The crossed out wheeled bin symbol informs you that the product should not be disposed of along with municipal waste and invites you to use the appropriate separate take back systems for product disposal If you need more information on the collection reuse and recycling systems please contact your local or regional waste administration You may also contact your ...

Page 20: ...ained in all of the homogeneous materials for this part is below the limit requirement of GB T26572 2011 表示本部件所有均质材料中含有的有害物质低于GB T26572 2011 的限量要求 X Indicates that said hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement of GB T26572 2011 表示用于本部件的至少一种均质材料中所含的危害物质超过GB T26572 2011 的限制要求 20 ...

Page 21: ......

Page 22: ...Copyright 2021 Cognex Corporation All Rights Reserved ...

Reviews: