background image

1.

Connect the Ethernet cable's M12 connector to the DataMan system's
ENET connector.

2.

Connect the Ethernet cable's RJ-45 connector to a switch/router or PC, as
applicable.

12

Summary of Contents for DataMan 475 Verifier

Page 1: ...DataMan 475 Verifier Quick Reference Guide 2022August04 Revision 6 3 2 5...

Page 2: ...e or malfunction from the following causes over voltage line noise electrostatic discharge ESD power surges or other irregularities in the power supply l Do not install Cognex products where they are...

Page 3: ...can be degraded or cables can be damaged or wear out faster if a service loop or bend radius is tighter than 10X the cable diameter l This device should be used in accordance with the instructions in...

Page 4: ...tes a hazard that could cause death serious personal injury or electrical shock CAUTION This symbol indicates a hazard that could result in property damage Note This symbol indicates additional inform...

Page 5: ...verview Number Item 1 Lens 2 Label Light attachment 3 Mounting holes M3 x 5mm 4 Indicator light ring 5 Ethernet connection 6 External lighting connection disabled for verification 7 Breakout cable con...

Page 6: ...ries contact your local Cognex sales representative Accessory Name Accessory Product Number Accessory Illustration Power and I O breakout cable M12 12 straight xx specifies length 5 m 10 m 15 m angled...

Page 7: ...Number Accessory Illustration Connection module 1 camera xx can be US EU UK or JP DMA CCM 1 xx Mounting Bracket Kit DMBK 470 MNT Pivot Mounting Bracket DM100 PIVOTM 00 External heat sink DMHS 370 470...

Page 8: ...Dimensions DataMan 475 Verifier 8...

Page 9: ...me ground Perform the following steps 1 Mount the verifier so that the distance from the bottom of the light housing to the plane of the code is 60 mm Tip Measure each corner of the light housing to 6...

Page 10: ...the verifier is grounded either by mounting the verifier to a fixture that is electrically grounded or by attaching a wire from the verifier s mounting fixture to frame ground or Earth ground If usin...

Page 11: ...nded at the far end Whatever this cable is plugged into usually a switch or router should have a grounded Ethernet connector Use a digital voltmeter to validate the grounding If the far end device is...

Page 12: ...1 Connect the Ethernet cable s M12 connector to the DataMan system s ENET connector 2 Connect the Ethernet cable s RJ 45 connector to a switch router or PC as applicable 12...

Page 13: ...nductive material to tie them back Keep bare wires separated from the 24 VDC wire 1 Verify that the 24 VDC power supply is unplugged and not receiving power 2 Attach the Breakout cable s 24 VDC and Gr...

Page 14: ...d immediately contact your Cognex Authorized Service Provider ASP or Cognex Technical Support CAUTION All cable connectors are keyed to fit the connectors on the DataMan system do not force the connec...

Page 15: ...uisition speed with 45 lighting degree accessory enabled is significantly less Practical acquisition rate is application dependent Lens Type 12 mm fixed focal length f 4 fixed aperture 2 3 inch sensor...

Page 16: ...xed focal length f 4 fixed aperture 2 3 inch sensor format C mount lens you cannot alter lens 35 mm fixed focal length f 4 fixed aperture 2 3 inch sensor format C mount lens users cannot alter lens Po...

Page 17: ...each polarity in each X Y Z axis 80 Gs 800 m s2 at 11 ms half sinusoidal with cables or cable plugs and appropriate lens cover attached Vibration Shipping and Storage IEC 60068 2 6 vibration test in...

Page 18: ...Speed 3 6 ft second 1 1 m second 4 6 ft second 1 4 m second Coplanarity Tolerance 3o of coplanar 2o of coplanar Approvals CE TUV FCC KC Industry Standards Compliance ISO IEC 15415 ISO IEC 15416 ISO IE...

Page 19: ...10 100 1000 Image Sensor 2 3 inch CMOS global shutter Image Sensor Properties 8 8 mm x 6 6 mm H x V 3 45 m square pixels Image Resolution pixels 2448 x 2048 1 Additional cooling measures may be requi...

Page 20: ...LED Wavelengths The following table shows LED types and the related peak wavelengths LED nm RED 660 20...

Page 21: ...1010 1 FCC Part 15 Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide rea...

Page 22: ...EC 61010 1 CAN CSA C22 2 No 61010 1 2012 UPD No 1 2015 07 UL 61010 1 2012 R 2015 07 UL 61010 1 2012 R 2015 07 EN 61010 1 2010 CB T V S D IEC EN 61010 1 CB report available upon request For European Co...

Page 23: ...vites you to use the appropriate separate take back systems for product disposal If you need more information on the collection reuse and recycling systems please contact your local or regional waste...

Page 24: ...olybrominated biphenyls PBB Polybrominated diphenyl ethers PBDE X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 SJ T 11364 O Indicates that said hazardous substance...

Page 25: ...Copyright 2021 Cognex Corporation All Rights Reserved...