Specifications
D902
In-Sight Illumination
Accessory
(ISLM-7000-xxx)
Cover is compliant with ANSI Z87.1-2003 Drop-Ball Impact Test (no fracture, 25.4mm
diameter steel ball, vertical drop from 127cm).
In-Sight Autofocus
Module Accessory
(ISAF-7000-8mm)
Number of Focus Cycles: 20,000
Network
Communication
1 Ethernet port, 10/100/1000 BaseT with auto MDIX. IEEE 802.3 TCP/IP Protocol. Supports
DHCP, static and link-local IP address configuration.
Power Consumption
24VDC ±10%, 1.5A maximum.
Note
: This product can have repetitive surges with high peak currents. A power source
rated for at least 5A continuous current is required to supply these surges and prevent
the product from operating unreliably.
Power Output
24VDC @ 750mA maximum to external light.
Material
Die-cast and extruded aluminum housing.
Finish
Painted.
Mounting
Four M4 threaded mounting holes on front and back of the vision system.
Dimensions
l
53.4mm (2.10in) x 60.5mm (2.38in) x 121.0mm (4.77in).
l
99.4mm (3.91in) x 60.5mm (2.38in) x 121.0mm (4.77in) with standard plastic C-Mount
cover (COV-7000-CMNT).
l
120.4mm (4.74in) x 60.5mm (2.38in) x 121.0mm (4.77in) with standard extended
plastic C-Mount cover (COV-7000-CMNT-EX).
l
135.7mm (5.34in) x 68.0mm (2.68in) x 121.0mm (4.77in) with wide plastic C-Mount
cover (COV-7000-CMNT-LG).
l
165.7 (6.52in) x 68.0mm (2.68in) x 121.0mm (4.77in) with wide plastic C-Mount cover
(COV-7000-CMNT-LG) and wide plastic C-Mount extender (COV-7000-CMNT-LGX).
l
95.1mm (3.74in) x 88.9mm (3.50in) x 121.0mm (4.77in) with Illumination (ISLM-7000-
xxx).
Weight
l
Vision system with no accessories attached: 380 g (13.4 oz.)
l
Standard plastic C-Mount cover (COV-7000-CMNT): 35 g (1.23 oz.)
l
Standard extended plastic C-Mount cover (COV-7000-CMNT-EX): 43 g (1.52 oz.)
l
Wide plastic C-Mount cover (COV-7000-CMNT-LG): 75.9 g (2.68 oz.)
l
Wide plastic C-Mount extender (COV-7000-CMNT-LGX): 25.0 g (0.88 oz.)
l
Autofocus module (ISAF-7000-8mm): 121.5 g (4.29 oz.)
l
Illumination (ISLM-7000-WHI): 153.5 g (5.41 oz.)
Case Temperature
1
0°C to 65°C (32°F to 149°F)
Storage Temperature
-20°C to 80°C (-4°F to 176°F)
Humidity
< 80% non-condensing
1
To verify case temperature, use the GetTemperature spreadsheet function, which returns the vision system case temperature in degrees
Celsius. For more information, see the
In-Sight
®
ViDi Help
file. A thermal scanner can also be used to determine the vision system case
temperature. Additional cooling measures are required if the case temperature cannot be kept below 65°C. Examples of such measures
include: extra heat sinking and/or air movement.
59