Specifications
16
3.1
General Specifications
3.2
Acquisition Trigger Input
The 1460 I/O Expansion Module provides access to the supported vision sensor’s high-
speed, opto-isolated acquisition trigger input. Unlike the general-purpose inputs, the acquisi-
tion trigger input is wired directly to the CCD imager circuitry, thus bypassing the sensor’s
operating system. The 1460 I/O Expansion Module’s micro controller also monitors the
acquisition trigger input (Figure 3-1).
Table 3-1: 1460 I/O Expansion Module General Specifications
SPECIFICATION
DESCRIPTION
Compatibility
In-Sight 3400 and In-Sight 5000 Series Vision Sensors
I/O
Trigger
1 opto-isolated, acquisition trigger input
Inputs
8 opto-isolated discrete (general-purpose)
Outputs
10 opto-isolated discrete (2 high-speed, 8 general-purpose)
General purpose Outputs – Maximum 60V dc, 2 Amps resistive, derated
at -33mA/C for surrounding air temperatures above 25°C
Communications Serial
1 RS-232C port (1200 to 115,200 baud rates)
RxD, TxD, and Flow control (RTS/CTS)
Status LEDs
1 each for power, external lights, acquisition trigger, inputs and outputs
1 each for Camera and Remote RS-232
Mechanical
Housing
Black plastic
Mounting
#3 DIN-rail (35 mm)
Dimensions
Width: 269.2mm (10.6"), Depth: 125.4mm (4.94"), Height: 63.5mm (2.5")
Terminal Block
26 to 16 AWG
Maximum torque 0.3 Nm (2.7 in-lb)
Weight
737.1 g (26 oz.) Opto-isolators and fuses installed, w/o retention bar.
Power
Camera
24VDC ±10%, 1.25 Amps, 30W supply
1
1.
Maximum draw when the 1460 I/O Expansion Module supplies power to an In-Sight sen-
sor, and when all inputs, outputs, and LED indicators are in use. Draw will be less than
30W under typical usage.
Light Input
12VDC to 24VDC
Light Output
12VDC to 24VDC
Environmental
Temperature
0 to 50C (operating), -10 to 65C (storage)
Humidity
10 to 90%, non-condensing (Operating and Storage)
Shock
30Gs per IEC 68-2-27 (Pending)
Vibration
2Gs per IEC 68-2-6 (Pending)
Certifications
CE, UL, FCC
Summary of Contents for 800-5815-1
Page 1: ......
Page 2: ......
Page 6: ...iv ...
Page 10: ...List of Figures viii ...
Page 12: ...List of Tables x ...
Page 16: ...Introduction 4 ...
Page 48: ...36 ...
Page 50: ...38 C 1 1 1460 I O Expansion Module Output to PLC Input ...
Page 52: ...40 C 1 3 1460 I O Expansion Module Output to Pilot Light Input ...
Page 54: ...42 C 1 5 1460 I O Expansion Module Input to PLC Output ...
Page 56: ......
Page 57: ... Q 6LJKW 0RGHO 2 SDQVLRQ 0RGXOH QVWDOODWLRQ DQG 5HIHUHQFH www cognex com 597 0029 02 ...