FAULT FINDING GUIDE
FAULT
POSSIBLE CAUSE
ACTION
FATAL I
2
C ERROR
displayed
Keypad does not bleep
Drinks cold
No motor operation
Machine inoperable;
no display
Heater tank
not filling
(a) Electrical
noise
(b)
MPU Board fault
(c) Software
error
(a) Keypad
damaged
(b) Keypad
disconnected
(c)
MPU Board fault
(a)
Heater fuse blown
(b)
Thermal cut-out tripped
(c) Desired
temperature
incorrectly set
(d)
Excessive scaling in
heater tank
(e)
Solid state relay fault
(f)
Low cut-out in program
incorrectly set
(g)
Temperature probe wet
(a) Jammed
motor
(b)
Power Supply failure
safety
trip
(a)
Power Supply failure
(a)
Low water pressure
(b)
Inlet valve fault
(c)
MPU Board fault
(a) Check
motors
(b)
Replace MPU Board
(c) Reset
power
(a) Replace
keypad
(b) Reconnect
(c)
Replace MPU Board
(a)
Check and replace
(b) Reset
trip
(c) Check
desired
temperature setting
(d)
Check tank and descale if
necessary
(e) Check
relay
(f)
Reset low cut-out setting
(g)
Dry probe and check
for
leaks.
(a)
Check motor operation
(b) Reset
power
(a)
Replace Power Supply
Board
(a)
Check water pressure
(b)
Check inlet valve
(c)
Replace MPU Board
Summary of Contents for NEVA 4
Page 1: ...NEVA 4 BEVERAGE MACHINE TECHNICAL MANUAL ...
Page 3: ...COFFEtek LTD 3 22 02 08 Issue 1 NEVA 4 This page is intentionally blank ...
Page 5: ...COFFEtek LTD 5 22 02 08 Issue 1 NEVA 4 This page is intentionally blank ...
Page 12: ...COFFEtek LTD NEVA 4 Issue 1 22 02 08 12 ...
Page 13: ......
Page 25: ...COFFEtek LTD 25 22 02 08 Issue 1 NEVA 4 This page is intentionally blank ...
Page 36: ...COFFEtek LTD NEVA 4 Issue 1 22 02 08 36 Section 4 Exploded Parts Diagram ...
Page 37: ...COFFEtek LTD NEVA 4 Issue 1 22 02 08 38 ...
Page 38: ...COFFEtek LTD 39 22 02 08 Issue 1 NEVA 4 ...