Picture
description
11
Installation & User Instructions
Page 11
Decanter Setting
To adjust the factory settings for the decanter first
remove the front panel from the door as shown in
the picture.
There is no requirement to disconnect any switches
from the door as the panel will unclip from the frame
and can then be rotated sat against the side of the
machine as shown.
When looking at the 2 timer relays the upper timer is
used to adjust the auto dispense time on product
coming from the left ingredient and the lower timer
sets the right ingredient time.
Normal press and release function is obtained using
the bottom front panel push buttons and decanter
dispense is obtained using the buttons located on
the top of the door panel.
The timers are factory set to the following settings:
Time Range
6-60 seconds
Timer Function
B
LEFT
STOP RIGHT