background image

Picture

description

Water valve

The Water valve is connected to the ejector and

opens the water-flow.

Push-button

The push buttons on the front panel
controls the water  valves.
Use only one button at a time.

5

Description Dispenser Parts 

Page 5

Summary of Contents for SLIM LINE

Page 1: ...Rev 090914 S EN Slim Line Service Manual SLIM LINE Juice Machine Din återförsäljare Your retail dealer ...

Page 2: ...ers instruction page 8 11 Maintenance and cleaning page 12 Handling and cleaning instructions page 13 Maintenance and cleaning page 14 Trouble shooting page 15 16 Technical Data and Notes Electrical Schematics Exploded View page 19 20 Spare parts list page 21 List Of Contents Index Main Index page 17 page 18 2 ...

Page 3: ...surized tube and to an electric wall socket by a power plug The water pressure is adjusted with the water regulator and the pressure is displayed on the manometer The water is chilled by the cooling block which in its turn is chilled by the air cooled compressor The water temperature is adjustable with a thermostat The mixing ratio product water is adjusted with the ejectors Pushing one of the fou...

Page 4: ...mixing ratio is adjusted on the ejectors When water flows through the ejector the concentrate mixes with the water The mixing ratio is regulated on the ejector There are two kinds one for products with cells and one for products without cells Turn the adjustment screws according to the label on the ejector in order to increase or decrease the amount of concentrate 4 Description Dispenser Parts Pag...

Page 5: ...Water valve The Water valve is connected to the ejector and opens the water flow Push button The push buttons on the front panel controls the water valves Use only one button at a time 5 Description Dispenser Parts Page 5 ...

Page 6: ...rmostat The thermostat keeps the temperature within correct range Factory adjusted do not adjust this may cause damage and water leakage in the dispenser Illumination Behind the front panel there is a low energy fluorescent lamp with the effect off 24 W The fluorescent lamp is a PL lamp Description Dispenser Parts Page 6 6 ...

Page 7: ...ray The drip tray is made of stainless steel with steel bars It is possible to connect drainage to the drip tray Large particle filter A large particle filter is fitted between the cooling block and the water valves It is possible to rinse the filter if needed Description Dispenser Parts Page 7 7 Removal of the front panel is necessary when setting the timers when the machine is fitted with decant...

Page 8: ...ser to it s position Note The dispenser weights about 35 kg Don t lift by door front panel Allow a space of min 40mm around the frame for air circulation Make sure that the dispenser level Adjustment can be made with the adjustable feet Adjustments 8 Installation User Instructions Page 8 Locating the machine ...

Page 9: ...n emergency leakage Connect the power plug to the wall socket Now the compressor starts and the front panel lights up The water pressure is factory adjusted to 2 2 bar which is the correct working pressure Check by pressing and holding one product button and reading the manometer If there is variations adjust by pulling black knob and turn it until you get a reading of 2 2 bar 9 Installation User ...

Page 10: ...fixes the tube Cut the tube to correct length and push it onto the elbow connector on the ejector Place a cup under the outlet pipe Dispense a glass of product by pressing the push button Check that the brix value mixing ratio is okay if not adjust To adjust the brix use the adjustment screw on the ejector The dispenser is now ready to use 10 Installation User Instructions Page 10 Initial settings...

Page 11: ...ted sat against the side of the machine as shown When looking at the 2 timer relays the upper timer is used to adjust the auto dispense time on product coming from the left ingredient and the lower timer sets the right ingredient time Normal press and release function is obtained using the bottom front panel push buttons and decanter dispense is obtained using the buttons located on the top of the...

Page 12: ...enture nipple 5 If the tube is to long cut it to the right length 6 Slip the tube to the venture nipple 7 Make sure that the tube is not twisted and shut the door to the dispenser 8 Place a cup under the outlet pipes and draw until the juice comes out Daily cleaning 1 Clean internal and external surface with a damped rag 2 Use the cleaning brush to clean the outlet pipes 3 Wet the brush in water a...

Page 13: ...of washing up liquid Connect the tube to the nozzle and wash it through Fig 4 3 Wet the brush in a hot water and sterilising solution Clean the outlet pipes by pushing the brush all the way through the pipe and back again Fig 5 4 Rinse the pipes with the water solution from the bottle 5 The pinch solenoid that the tube runs through should be cleaned on a regular basis by pouring a hot water and st...

Page 14: ... Shut the dispenser door and put a cup under the outlet pipes rinse the venture and the outlet pipes by pressing the respective push buttons 4 Use the cleaning brush to clean the outlet pipes 5 Wet the brush in water and put it in the outlet pipe from the inside of the door Return the boxes and connect the tubes to the ventures 14 Maintenance Cleaning Page 14 Cleaning ...

Page 15: ...bag Nothing happens when I push the buttons and there is no clicking sound No power to the valves Check the valve on off sw inside the door Thermo fuse in the transformer has cut On older models a fuse has blown Remove power to the dispenser and put it back on after 10 sec Change fuse Nothing happens when you push the buttons and there is a clicking sound Water supply turned off Check water supply...

Page 16: ...pinch solenoid The ejector is not adjusted correctly Dirt in the water valve Call service Call service It constantly drips fluid from the outlet pipes Call service Troubles with cooling system The drinks are not cold Failure in thermostat Call service Failure in cooling system Call service 16 Trouble Shooting Page 16 Fault finding ...

Page 17: ...e 3 It is strongly recommended to use some sort of water isolator in the water line in case of an emergency leakage Note 4 Maximum ambient temperature in the room where the dispenser is located should not exceed more then 25 C Note 5 If the dispenser has frozen check water tubs and connections inside the dispenser before running the dispenser again 17 Technical Data Page 17 Specifications Operatio...

Page 18: ...alve Right pinch valve Key switch Left time relay Right time relay Left water valve Right water valve Middle water valve Electrical Schematic Slim Line DecanterVersion Thermostat 230VAC 50Hz GND Compressor 24VAC Transformer Fan Door light Starter Left button Right button Middle button Left pinch valve Right pinch valve Key switch Left water valve Right water valve Middle water valve Electrical Sch...

Page 19: ...19 Technical Drawings Page 19 Exploded diagrams main cabinet 23 3 4 5 6 16 7 17 18 14 13 23 20 21 22 15 19 29 ...

Page 20: ...20 Technical Drawings Page 20 Exploded diagrams cabinet door 8 8 8 28 24 25 26 27 2 1 10 12 9 11 Standard Door Assembly Decanter Door Assembly ...

Page 21: ...104588 Transformer 230V 24V 55VA 17 S1104584 Thermostat 18 S302319 Manometer 19 S302075 Compressor Electrolux GL80TB 20 S302109 Foot 21 S302059 Ballast 22 S105116 Fan motor 5W 23 S302318 Water regulator Not shown S302020 Cleaning brush S302031 Plug drip tray Slim Line S302092 Cleaning bottle S302049 Printed film door panel S302041 Push button panel Slim Line S302037 Water hose S302278 Cable connec...

Page 22: ...t no 1704153 FOR SERVICE Please contact your retail dealer Din återförsäljare Your retail dealer COFFEE QUEEN AB Box 960 671 29 ARVIKA besöksadress Korpralsv 1B Tel vxl 46 0 570 47700 Fax 46 0 570 47719 E mail info coffeequeen se www coffeequeen se ...

Reviews: