19.
Problem:
Leakage between group and filterholder when machine is brewing.
Cause 1:
Brew groups filter spring are worn out.
Cures:
Replace it.
Cause 2:
1 cup filter/2 cup filter is damaged.
Cures:
Replace it.
Problem:
Water leaks from the expansions valve.
Cause 1:
Gasket, expansions valve are worn out.
Cures:
Replace.
Cause 2:
The pumps by-pass valve failes.
Cures:
Check and trashing the valve piston.
Shutting the machine down should be done by authorized personnel.
Eliminate the pressure from the hydraulic circuit, disconnect the electric flex from the mains
power supply network and dispose of substances which are potentially harmful to the environment.
Place the machine in a suitable place, out of the reach of children or unsuitable people.
For dismantling the machine as refuse, return it to the supplier or take it to an
authorized refuse collection centre.
Do not dispose of it in the environment.
Fault:
10. Faults and routine repairs
Crema Compact och Digital