background image

English 

 

Congratulations on having purchased a Coemar product. You have assured yourself of a fixture of the highest quality, both in the 

componentry and in the technology used. We renew our invitation to you to complete the service information form on the previous 

page. This will assist in providing prompt and accurate advice from your Coemar service centre, which you can thoroughly trust and 

to which you can submit any requests for service or information. Following the instructions and procedures outlined in this manual 

will ensure the maximum efficiency of this product for years to come. 

1.Packaging and transportation 

 
1.1 Packaging 

Open the packaging and make sure that no part of the equipment has suffered any damage during the transportation. In case of 

damage to the fixture, contact your currier and your supplier immediately by telephone, fax or email, and inform them you will  

formally notify them in writing through registered letter. 

Packing List 

Make sure the packaging contains: 

1 the 

Infinity ACL M 

projector. 

2 the instruction manual. 

3 the Cam

-

Lock support brackets. 

1.2 Trasportation 

The 

Infinity ACL M

 must be transported exclusively in its original packaging or in an appropriate flight case. 

2. General information 

 
2.1 Important safety information. 
Fire prevention: 
1.Infinity ACL M

 utilizes a Philips MSR 700 Gold Mini Fast Fit or a Philips MSR Gold 575 MiniFast Fit lamp, the use of any 

alternative lamp might be risky and will make the warranty of the fixture null and void. 

2.

 Never locate the fixture on any flammable surface. 

3.

 Minimum distance from flammable materials: 0.5m. 

4.

 Minimum distance from the closest illuminable surface: 0.5m. 

5.

 Replace any blown or damaged fuses only with identical ones, both in size and value. Refer to the connection diagram if there is 

any doubt. 

6.

 Connect the projector to mains power protected by a thermal magnetic circuit breaker. 

Preventing electric shock: 
1.

 Presence of high voltage inside of the fixture. Insulate the projector from mains supply before opening or performing any function 

which involves touching the inside of the fixture, including lamp replacement. 

2.

 For the connection to the mains, adhere strictly to the guidelines outlined in this manual.. 

3.

 The level of technology of 

Infinity ACL M

 requires the use of specialised personnel for all service applications; refer all work to 

your authorised 

Coemar 

service centre. 

4.

 A good earth connection is essential for the proper functioning of the projector. Never connect the fixture if there is no earth 

connection. 

5.

 Mains cables must not come into contact with other cables. 

6.

 Do not operate the projector with wet hands or in an area where water is present. 

7.

 The fixture must never be located in an exposed position, or in areas of extreme humidity.  

Protection against ultraviolet radiation(UV): 
1.

 Never turn on the lamp if any of the lenses, filters, or the plastic housing are damaged; their shielding functions will only operate 

efficiently if they are in perfect working order. 

2.

 Never look directly in the direction of the lamp when it is operating. 

Safety:

 

1.

 The projector must always be installed with bolts, clamps, or other fixing devices which are suitably rated to support the weight of 

the projector. 

2.

 Always use a secondary safety fixing device with chain or steel wire of a suitable rating to sustain the weight of the unit in case of  

failure of the principal fixing point. 

3.

 The external surfaces of the unit, at various points, may reach 150°C. Never handle the unit until at least 10 minutes have 

elapsed since the lamp was turned off 

4.

 Always replace the lamp if any physical damage is evident. 

5.

 Never install the fixture in an enclosed area lacking sufficient air flow; the room temperature must not exceed 35°C. 

6.

 Wait at least 10 minutes after the unit has been turned off before attempting to replace  or remove the lamp. Always use 

protection gloves while replacing the lamp. 

7.

 The projector contains electronic and electrical components which must under no circumstances be in contact with water, oil or 

any other liquid. Failure to do so will compromise the proper functioning of the projector. 

Projector movement

The projector has a pan range of 540° in its base and a tilt range 262° in its yoke; do not obstruct the projector whilst it is moving.  

 

Forced ventilation 

On the body of the projector you will note several air vents housing several cooling fans, both in the basis and in the body. To avoid 

any problems associated with overheating, never obstruct any of these vents, as this would seriously compromise the proper 

operation of the unit. 

Summary of Contents for Infinity ACL M

Page 1: ...Infinity ACL M instruction manual manuale di istruzioni Version 1 0 DIS127 ...

Page 2: ...r in answering any technical enquiries with the utmost speed and accuracy Prendete nota nello spazio apposite dei dati relative al modello e al rivenditore del vostro Infinity ACL M questi dati ci permetteranno di assistervi con la massima rapidità e precisione WARNING the security of the fixture is granted only if these instructions are strictly follow therefore it is absolutely necessary to keep...

Page 3: ...tions 14 8 1 Quick guide to menù 14 8 2 Rapid count 14 8 3 Main functions 15 8 4 Measures 17 8 5 Display setup 17 8 6 Demo mode 18 8 7 Special mode and electronic motor alignment 18 9 Lamp installation and alignment 20 9 1 Lamp installation 20 9 2 Aligning the lamp in the optical path 21 10 Operating on inside groups 21 10 1 How to open the projector 22 10 2 How to extract the gobos and colour cha...

Page 4: ...delines outlined in this manual 3 The level of technology of Infinity ACL M requires the use of specialised personnel for all service applications refer all work to your authorised Coemar service centre 4 A good earth connection is essential for the proper functioning of the projector Never connect the fixture if there is no earth connection 5 Mains cables must not come into contact with other cab...

Page 5: ...or inadequate maintenance 3 The warranty is immediately void if the projector has been tampered or opened by unauthorised personnel 4 The warranty does not extend to fixture replacement 5 Both the serial number and the model of the projector are required for any advice or service from your authorised service centre 2 3 EC Norms The projector meets all fundamental applicable EC requirements 3 Produ...

Page 6: ... installations on a reticular structure Coemar provides a set of Cam lock support brackets which are included in the packaging The Cam lock bracket is one fourth turn supports Before using it for supporting the projector make sure that it is correctly seated and firmly tightened into position Components description A Front lens assembly B Body C Gobos assembly D Body casing E Colour changer assemb...

Page 7: ...ction If the Infinity ACL M is fixed to a structure the use of a safety chain is recommended in order to meet the current relevant safety standards The safety chain must pass through the holes A and then fixed to the structure itself If using steel wires or chains which have not been manufactured by Coemar make sure that they are suitable for holding the weight of the unit 5 Powering up 5 1 Connec...

Page 8: ...n signal arrives from a DMX 512 console with Cannon XLR5 5 poles pins 4 and 5 must not be connected WARNING Make sure that screening and conductors are not in contact one another or with the metal housing of the connector Pin n 1 and housing must never be connected to the unit power supply 6 1 Connection through ArtNet protocol The ArtNet protocol allows enabled projectors to operate and to be see...

Page 9: ...y the signal DMX 512 Each projector utilises 20 address channels 16 bit for its complete operation and is controlled by a DMX 512 signal for further information see section 7 2 DMX functions When powered up initially each projector will show A001 which indicates DMX address 001 a projector thus addressed will respond to commands of channel 1 to 20 from your DMX 512 controller A second unit must be...

Page 10: ...nal proportional control of the shutter profile from open to closed 67 187 26 73 proportional random strobe effect non synchronised variable speed from slow to fast 188 244 74 96 step shutter open zap off 245 255 96 100 step open 0 9 0 4 proportional from maximum to minimum aperture 10 255 4 100 step open 0 9 0 4 proportional from maximum to minimum aperture 10 124 4 49 step minimum diameter 125 1...

Page 11: ...h the strobe effect speed and mode selected by strobe channel 7 11 30 4 12 zap effect flicker and speed adjustable speed and mode selected by strobe channel 7 31 128 12 50 proportional movement of the strobo profile 129 249 51 98 black out of the light beam during PAN TILT movement gobos wheel and color wheel 250 255 98 100 no effect 0 10 0 4 proportional movement of the gobo wheels through 360 11...

Page 12: ...s displayed for the different functions in the following 3 manners 1 Pressing the or buttons will cause the count to be quicker 2 Pressing first and then and then holding them down simultaneously will cause the numbers to jump to the highest value 3 Pressing first and then and then holding them down simultaneously will cause the numbers to jump to the lowest value DISPLAY SETUP allows the manageme...

Page 13: ...IGH fans are always set at full power STANDARD the on off state of the lamp s controller by DMX signal ON the lamp remains always on please see DMX chart It perform the reset function of the fixture Keeping pressed ENTER and MENU buttons during reset it will access SPECIAL MODE see special mode menu Restores all the functional settings excepts for address motors tuning and odometers to default val...

Page 14: ... the same DMX change Panoramic working mode that reduces rotating angle from 540 to 400 It inverts the vertical moving beam direction from upwards to downwards or vice versa by the same DMX level change It allows to enable or disable the optical sensors which check the base s or the yoke s position or body and perform the automatic return if moved accidentally It allows to engage or disengage the ...

Page 15: ...software version sw LCD master software installed on to LCD master board sw MOTOR slave software installed on to MOTOR slave board TEMPERATURE VOLTAGE DMX INPUT MEASURE DMX RATE ALARM STATUS LAMP STATUS USAGE HOURS SOFTWARE VERSION BALLAST MEASURES It shows the operating information of the ballast Lamp type installed lamp type 575 o 700 W Actual power Instant power in W emitted from the ballast T1...

Page 16: ... the electronic motor alignment of the projector motors in the optical system this procedure is performed by Coemar at the factory during the testing in order to obtain particular effects or in the case of internal components being replaced motors electronic boards sensors etc it may be necessary to change this setting Altering the default settings performed by Coemar may radically alter the funct...

Page 17: ...be restored each time the lamp being changed in order to get a correct reading of lamp s life Are you sure Are you sure Are you sure Are you sure It makes the fixture ready to transfer the LCD software on to the PC It make the fixture ready to transfer the MOTORS software on to the PC It makes the fixture ready to receive the MOTORS software from the PC It makes the fixture ready to receive the LC...

Page 18: ...er turning off the lamp The lamp is of the mercury vapour type with discharge ignition This type of lamp operates at high internal pressure and a slight risk of explosion exists if the lamp is operated beyond its recommended life Therefore we recommend to replace the lamp within the specified lamp life Always handle the lamp with care avoiding to touch it with bare hands 9 1 Lamp installation 1 Us...

Page 19: ...d If the lamp is not correctly aligned a hot spot to the most central part of the beam possible and then flatten the beam to maximum uniformity The combined regulation of the three adjusters allows horizontal vertical and axial regulation of the lamp 10 Operating on inside groups The fixture allows the extraction of both gobos and colour changer assemblies in order to facilitate inspection gobos r...

Page 20: ...ined Glass gobos defined Working area ø mm Diametro utile mm Up to 21 Fino a 21 Up to 27 Fino a 27 Up to 21 Fino a 21 Thickness mm Spessore mm 0 5 mm From 1 to 4 Da 1 a 4 From 1 to 4 Da 1 a 4 Overall ø mm Diametro totale mm Up to 27 Fino a 27 Up to 26 8 Fino a 26 8 Up to 26 8 Fino a 26 8 In case of replacing of metal gobos we strongly recommend to use special gobos provided by Coemar In any case g...

Page 21: ... 3 Remove the old gobo 4 Insert the new gobo respecting the black side Avoid to touch the uncoated side 5 On the gear there is an etched reference point use it to orient the gobo and fix on to the projector 6 Mount the spring ensuring it keeps the gobo firm 7 Check the gobo freely rotate and mount the gobos assembly in the fixture following backwards the procedure explained in the previous section...

Page 22: ...ore thick than 1 mm 10 7 Reassembly the groups on the projector In order to reassembly the two groups in place just follow backwards the procedure explained at the beginning of this chapter half insert the gobo assembly and incline it toward the front of the fixture Insert the colour changer and then full insert the gobo assembly Fix the two groups by their screws connect the cables and fix them a...

Page 23: ...mpressor If necessary do not hesitate to carry this out even after a shorter period of time 11 2 Periodic maintenance Lamp Check the lamp and replace it if there is any observable damage or deformation or if or if the time limit is close check the resettable counter Mechanical parts Periodically check the movement of all mechanical devices and check driving belts gears and lens guides Replace them...

Page 24: ... fans ERR Ballast Temp 2 Secondary ballast temperature too high Check that the ambient temperature does not exceed 40 C check also the proper functioning of the fans ERR Vinp line low Too low main power input Main power voltage is too low it must be at least 90 Vac ERR Vout lamp high Too high lamp voltage Lamp can be exhausted and so consume more power than normal Replace the lamp and if needed re...

Page 25: ...t turn on at all The projector is too hot Let the fixture cool down Check that the air vents above the cooling fans are not obstructed and that the fans are working correctly Ensure that the ambient temperature is below 35 C Projection brightness appears reduced Lamp may be exhausted or not properly aligned to optical path Replace the lamp if exhausted Align the lamp to optical path Information on...

Page 26: ...2 A 46042 Castel Goffredo Mantova Italy ph 39 0376 77521 fax 39 0376 780657 info coemar com Coemar si riserva il diritto di apportare modifiche senza preavviso Coemar reserves the right to effect modifications without notification ...

Reviews: